170M FUSE Search Results
170M FUSE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCKE800NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B | Datasheet | ||
| TCKE800NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B | Datasheet | ||
| TCKE805NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE805NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE812NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet |
Documents mentioning 170M FUSE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| e4273 | High Speed Fuses Bussmann® fuses for Danfoss Drives VLT® 6000 Series 200-240 V Standard Alternate Model HP KW E4273 RK1/JDDZ E56412 JFHR2 E4273 J/JDDZ E4273 T/ JDDZ 6002 1.5 1.1 KTN-R-10 - JKS-10 JJN-10 6003 2.0 1.5 KTN-R-10 - JKS-10 JJN-10 6004 3.0 2.2 |
Original | ||||
| Technical information Module Stacks Introduction: | Technical information Module Stacks Introduction: eupec offers module stacks for all well-known kinds of circuits for the lower and medium power range. For the reason of the insulated construction of the modules, the heatsinks do not conduct any voltage and can be earthed in the unit |
Original | ||||
| Technical information Module Stacks Introduction: | Technical information Module Stacks Introduction: eupec offers module stacks for all well-known kinds of circuits for the lower and medium power range. For the reason of the insulated construction of the modules, the heatsinks do not conduct any voltage and can be earthed in the unit |
Original | ||||
| € Technische Erläuterungen Modulsätze Allgemeines | € Technische Erläuterungen Modulsätze Allgemeines eupec bietet für alle gängige Schaltungsarten Modulsätze für den unteren und mittleren Leistungsbereich an. Durch den isolierten Aufbau der Module führen die Kühlblöcke keine Spannung und können problemlos in der Anlage geerdet |
Original | ||||
| Bussmann® Square Body - US-Style 1000V (IEC) Size | Bussmann® Square Body - US-Style 1000V (IEC) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 50 63 80 100 125 160 200 250 315 |
Original | ||||
| Bussmann® Square Body - US-Style 1000V (IEC) Size | Bussmann® Square Body - US-Style 1000V (IEC) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 250 315 350 400 450 500 550 630 700 |
Original | ||||
| Bussmann® Square Body - US-Style 1000V (IEC) Size | Bussmann® Square Body - US-Style 1000V (IEC) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160-630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 160 200 250 315 350 400 450 500 550 |
Original | ||||
| Bussmann® Square Body - Flush End Contact 1000V | Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160–630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 160 200 250 315 350 400 450 |
Original | ||||
| Bussmann® Square Body – DIN 43 653 1000V | Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 250-800A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 250 315 350 400 450 500 |
Original | ||||
| Bussmann® Square Body – DIN 43 653 1000V | Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160-630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 160 200 250 315 350 400 |
Original | ||||
| Bussmann® Square Body - Flush End Contact 1000V | Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 250–800A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 250 315 350 400 450 500 550 |
Original | ||||
| Bussmann® Square Body – DIN 43 653 1000V | Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 50 63 80 100 125 160 200 |
Original | ||||
| Bussmann® Square Body - Flush End Contact 1000V | Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50–400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 50 63 80 100 125 160 |
Original | ||||
| Bussmann® Square Body - Flush End Contact 1000V | Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 3 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 315–1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 315 350 |
Original | ||||
|
|
||||||
| Bussmann® Square Body – DIN 43 653 1000V | Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 3 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 315-1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 315 350 |
Original | ||||
| hm-7681rp | H M - 7 6 8 0 R P /8 1 R P H A R R IS r iv iv P O W E R D O W N IK x 8 P R O M S E M IC O N D U C T O R PRODUCTS DIVISION i! A DIVISION OP HARRIS CORPORATION H M -7680R P - Open Collector Outputs HM-7681RP - "Three State” Outputs Preliminary Pinouts Features |
OCR Scan | ||||
| SY M B O L S & C O D ES E X P L A IN E D IN TYPE | SY M B O L S & C O D ES E X P L A IN E D IN TYPE No. CROSS-INDEX & TECHNICAL SECTIONS A \ Indicators of separate manufacturers producing same type number (non-JEDEC) whose characteristics are not the same. i This manufacturer-identifying symbol (assigned by D.A.T.A.) is an integral part of the type number (in Type No. Cross Index, |
OCR Scan | ||||
| SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX | SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX & TECHNICAL SECTIONS A \ Indicators of separate manufacturers producing same type number (non-JEDEC) whose characteristics are not the same. i This manufacturer-identifying symbol (assigned by D.A.T.A.) is an integral part of the type number (in Type No. Cross Index, |
OCR Scan | ||||
| PowerFlex 40 Sample Specification GENERAL | PowerFlex 40 Sample Specification GENERAL REFERENCES Designed to meet the following specifications: • NFPA 70 - US National Electrical Code • NEMA ICS 3.1 - Safety standards for Construction and Guide for Selection, Installation and Operation of Adjustable Speed Drive Systems. |
Original | ||||
| SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX | SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX & TECHNICAL SECTIONS A \ Indicators of separate manufacturers producing same type number (non-JEDEC) whose characteristics are not the same. i This manufacturer-identifying symbol (assigned by D.A.T.A.) is an integral part of the type number (in Type No. Cross Index, |
OCR Scan | ||||
| transformer protection | Equipment Protection Transformers — 600V or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers, requirements for conductor protection per Articles |
Original | ||||
| 2364f | Allen-Bradley Parallel DC Bus Supply Configurations (Using Bulletin 2364E NRUs and Bulletin 2364F RGUs) Bulletin 2364P User Manual Important User Information Solid-State equipment has operational characteristics differing from those of electromechanical equipment. “Safety Guidelines for the |
Original | ||||
| SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX | SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX & TECHNICAL SECTIONS A \ Indicators of separate manufacturers producing same type number (non-JEDEC) whose characteristics are not the same. i This manufacturer-identifying symbol (assigned by D.A.T.A.) is an integral part of the type number (in Type No. Cross Index, |
OCR Scan | ||||
| SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX | SYMBOLS & CODES EXPLAINED IN TYPE No. CROSS-INDEX & TECHNICAL SECTIONS A \ Indicators of separate manufacturers producing same type number (non-JEDEC) whose characteristics are not the same. i This manufacturer-identifying symbol (assigned by D.A.T.A.) is an integral part of the type number (in Type No. Cross Index, |
OCR Scan | ||||