TOROID CORES TYPE TABLE Search Results
TOROID CORES TYPE TABLE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-059FTYPEMM-025 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft | |||
| CO-059FTYPEMM-010 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft | |||
| CO-059FTYPEMM-050 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft | |||
| CO-059FTYPEMM-003 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft | |||
| CO-059FTYPEMM-006 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft |
Documents mentioning TOROID CORES TYPE TABLE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| arnold | Soft Magnetics Application Guide p. 30.1 March 2000 GROUP ARNOLD ® Table of Contents Introduction… 30.3 Basics of Magnetics… 30.4 – 30.11 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Energy… 30.4 |
Original | ||||
| arnold | Soft Magnetics Application Guide p. 30.1 March 2000 GROUP ARNOLD ® Table of Contents Introduction… 30.3 Basics of Magnetics… 30.4 – 30.11 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Energy… 30.4 |
Original | ||||
| STEWARD TOROIDS Table Of Contents Steward & | STEWARD TOROIDS Table Of Contents Steward & Quality Assurance… 3 Quality Philosophy… 3 |
Original | ||||
| 14th Edition 1 Table of Contents Quality Policy | 14th Edition 1 Table of Contents Quality Policy Statement… I.F.C. Introduction… 2 |
Original | ||||
| 14th Edition 1 Table of Contents To search for a | 14th Edition 1 Table of Contents To search for a part number use "CTRL F" or click on binocular icon above. Click here for Part Number Index and locator… Introduction… 2 |
Original | ||||
| siferrit | SIFERRITâ Materials SIFERRIT® materials Based on IEC 60401, the data specified here are typical data for the material in question, which have been determined principally on the basis of toroids (ring cores). The purpose of such characteristic material data is to provide the user with improved means for |
Original | ||||
| PRODUCT SELECTION GUIDE 2001 A Y AG E O C O M PA | PRODUCT SELECTION GUIDE 2001 A Y AG E O C O M PA N Y List of contents page This Selection Guide offers an overview of the product ranges made by FERROXCUBE It contains short-form data for quick selection by development engineers and offers an overview for |
Original | ||||
| 1 15th Edition Table of Contents To search for a | 1 15th Edition Table of Contents To search for a part number click on binocular icon above or click below for product category. Our Position on Quality and the Environment…I.F.C. |
Original | ||||
| selection guide | PRODUCT SELECTION GUIDE 2003 A Y A G E O C O M P A N Y List of contents List of contents (continued) page page General introduction Application matrix 2 8 Power conversion and Signal processing Materials and applications Bobbins and accessories Integrated Inductive Components (IIC) |
Original | ||||
| dynex | AN 5946 Driving Dynex High Power IGBT modules with Concept Gate Drives Application Note AN5946-2.0 September 2009 LN26854 Author: Dinesh Chamund Introduction Dynex Semiconductor manufactures a variety of IGBT modules ranging from 1200V to 6500V and 100A to 2400A. |
Original | ||||
| gapped cores | Part Number Identification – How to Order UNGAPPED CORES and TOROIDS 3. 1. Typical Part Number S D-4 30 19 -UG-xx Coating/Shape Code (See Note 2) Geometry Code For standard ungapped cores a two letter code indicates the geometry. Unit of Code Geometry Example |
Original | ||||
| magnetic cores for switching power supplies | ® Division of Spang & Company Magnetic Cores For Switching Power Supplies INTRODUCTION The advantages of switching power supplies (SPS) are well documented. Various circuits used in these units have also been sufficiently noted in literature. Magnetic cores play an |
Original | ||||
| IEC 2001 - da ERRATA CORRIGE 6-02-2001 10:46 | IEC 2001 - da ERRATA CORRIGE 6-02-2001 10:46 Pagina 9 Current-compensated Noise Suppression Chokes 9 IEC 2001 - da ERRATA CORRIGE 6-02-2001 10:46 Pagina 10 Current-compensated Noise Suppression Chokes A distinct category of filters, especially designed to supress the “common mode” or asymmetrical |
Original | ||||
| s V E R X 1 T A INI D 1 c INI A L G 7m j i m 111 | s V E R X 1 T A INI D 1 c INI A L G 7m j i m 111 \ r > V\ CAPPED TOROIDAL INDUCTORS ______________________________ J # S table gap p e d fe rrite c o re s # L o w e xte rn a l m a g n e tic fie ld # L o w DCR # V ery h ig h c o re s a tu ra tio n c u rre n t |
OCR Scan | ||||
|
|
||||||
| Application Notes Filter Applications Application | Application Notes Filter Applications Application notes 1 Cores for filter applications 1.1 Gapped cores for filter/resonant circuits Basic requirements: L C ■ low tan δ ■ close tolerance for A L value ■ close tolerance for temperature coefficient ■ low disaccommodation factor DF |
Original | ||||
| 71m654x | 71M654x A Maxim Integrated Products Brand APPLICATION NOTE AN_654x_021 AUGUST 2011 Magnetic Shielding for Pulse Transformers Introduction The 71M654x family of electricity metering ICs are designed to be used with CTs or with shunt resistors that are connected to 71M6xxx Remote Sensor Interfaces. These 71M6xxx Remote Sensor Interfaces are normally connected to the 71M654x ICs via small low-cost pulse transformers. |
Original | ||||
| Ferrites and accessories Application notes Date: | Ferrites and accessories Application notes Date: September 2006 Data Sheet EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited. Application notes |
Original | ||||
| vectra | V E R X 1 o A L S T A INI D 1 IM G CAPPED INDUCTORS siiiitiSffiïl®«:iiaSliiS*®ï!l-«a;Si®lll®Pi? # Stable gapped ferrite cores # Low external magnetic field # Low DCR # Very high core saturation current # Operation -55 to +125°C Vectra®, a liquid crystal polymer plastic meeting the requirements of |
OCR Scan | ||||
| inverter transformer core design and material selection | ® Division of Spang & Company Inverter Transformer Core Design and Material Selection INTRODUCTION… 2 TYPICAL OPERATION… 2 |
Original | ||||
| Product Information Non-Intrusive Hall-Effect | Product Information Non-Intrusive Hall-Effect Current-Sensing Techniques Provide Safe, Reliable Detection and Protection for Power Electronics By Paul Emerald Abstract contact’ Hall-effect circuitry for sensing/detecting motion, direction, position, and measuring/monitoring current. |
Original | ||||
| INDUCTOR APPLICATIONS Contents terminology… 3-46 | INDUCTOR APPLICATIONS Contents terminology… 3-46 data sheet parameters… 3-46 other parameters… 3-47 inductor types… 3-47 |
Original | ||||
| toroidal transformer | THE ADVANTAGES AND BENEFITS OF USING AMVECO TOROIDAL TRANSFORMERS On this page you can learn about the advantages and benefits of using our toroidal transformers. First we would like to list four features that are unique to AMVECO and its line of toroidal transformers. Four features that you will surely benefit from. |
Original | ||||
| toroidal transformer | THE ADVANTAGES AND BENEFITS OF USING AMVECO TOROIDAL TRANSFORMERS On this page you can learn about the advantages and benefits of using our toroidal transformers. First we would like to list four features that are unique to AMVECO and its line of toroidal transformers. Four features that you will surely benefit from. |
Original | ||||