Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SDAINL Search Results

    SF Impression Pixel

    SDAINL Price and Stock

    Eaton Corporation

    Eaton Corporation SDAINLM12(230V50HZ,240V60HZ)

    Star-delta; 5.5kW; 12A; 230÷240VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM12(230V50HZ,240V60HZ) 1 1
    • 1 $399.33
    • 10 $368.18
    • 100 $368.18
    • 1000 $368.18
    • 10000 $368.18
    Buy Now

    Eaton Corporation SDAINLM30(230V50HZ,240V60HZ)

    Star-delta; 15kW; 30A; 230÷240VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM30(230V50HZ,240V60HZ) 1 1
    • 1 $533.81
    • 10 $499.49
    • 100 $499.49
    • 1000 $499.49
    • 10000 $499.49
    Buy Now

    Eaton Corporation SDAINLM55(RDC24)

    Star-delta; 30kW; 55A; 24VDC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM55(RDC24) 1
    • 1 $1000.21
    • 10 $928.77
    • 100 $928.77
    • 1000 $928.77
    • 10000 $928.77
    Get Quote

    Eaton Corporation SDAINLM70(400V50HZ)

    Star-delta; 37kW; 70A; 400VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM70(400V50HZ) 1
    • 1 $934.67
    • 10 $867.90
    • 100 $867.90
    • 1000 $867.90
    • 10000 $867.90
    Get Quote

    Eaton Corporation SDAINLM55(230V50HZ,240V60HZ)

    Star-delta; 30kW; 55A; 230÷240VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM55(230V50HZ,240V60HZ) 1
    • 1 $750.51
    • 10 $696.90
    • 100 $696.90
    • 1000 $696.90
    • 10000 $696.90
    Get Quote

    Documents mentioning SDAINL

    Document Partial File Text Tags Type PDF
    sdainlm45
    Type: SDAINLM45(230V50HZ,240V60HZ) Article No.: 278386 Sales text S−D−contactors,22kW/400V,AC−operated Operating frequency max. 30 starts/hour AC operation Ordering information Rated operational current AC−3 380 V 400 V Ie A 45 AC−3 220 V 230 V P
    Original PDF
    dilm32
    Type: ZB32−4 Article No.: 278449 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    dilm32
    Type: ZB32−10 Article No.: 278451 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    dilm32
    Type: ZB32−32 Article No.: 278454 Ordering information Overload release, min. – max. Ir A 24 – 32 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    sdainl moeller
    Ordering Star-delta starter combinations Ordering Star-delta starter combinations Contactor combinations SDAINL Moeller HPL0211-2007/2008 Rated operational current AC-3 Max. rating for three-phase motors, 50 – 60 Hz 380 V 400 V 380 V 400 V Ie 220 V 230 V
    Original PDF
    sdainlm30
    Type: SDAINLM30(400V50HZ,440V60HZ) Article No.: 278363 AC operation Ordering information Rated operational current AC−3 400 V Ie A 30 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 7.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    dilm32
    Type: ZB32−1,6 Article No.: 278447 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    dilm32
    Type: ZB32−1 Article No.: 278446 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    zb12
    Type: ZB12−12 Article No.: 278441 Ordering information Overload release, min. – max. Ir A 9 – 12 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    sdainlm16
    Type: SDAINLM16(110V50HZ,120V60HZ) Article No.: 278308 AC operation Ordering information Rated operational current AC−3 400 V Ie A 16 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 4 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    zb12
    Type: ZB12−10 Article No.: 278440 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    dilm32
    Type: ZB32−16 Article No.: 278452 Ordering information Overload release, min. – max. Ir A 10 – 16 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    sdainlm12
    Type: SDAINLM12(230V50HZ,240V60HZ) Article No.: 278286 AC operation Ordering information Rated operational current AC−3 400 V Ie A 12 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 3 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    sdainlm16
    Type: SDAINLM16(230V50HZ,240V60HZ) Article No.: 278311 AC operation Ordering information Rated operational current AC−3 400 V Ie A 16 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 4 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    sdainlm55
    Type: SDAINLM55(110V50HZ,120V60HZ) Article No.: 278408 AC operation Ordering information Rated operational current AC−3 400 V Ie A 55 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 15 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    dilm32
    Type: ZB32−24 Article No.: 278453 Ordering information Overload release, min. – max. Ir A 16 – 24 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    zb12
    Type: ZB12−1 Article No.: 278435 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    sdainl
    Type: SDAINLM45(230V50HZ,240V60HZ) Article No.: 278386 AC operation Ordering information Rated operational current AC−3 400 V Ie A 45 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 11 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    zb12
    Type: ZB12−4 Article No.: 278438 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    zb12
    Type: ZB12−6 Article No.: 278439 Ordering information Overload release, min. – max. Ir A 4–6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 Short−circuit protection Type “1” coordination
    Original PDF
    sdainlm55
    Type: SDAINLM55(230V50HZ,240V60HZ) Article No.: 278411 AC operation Ordering information Rated operational current AC−3 400 V Ie A 55 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 15 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    dilm32
    Type: ZB32−2,4 Article No.: 278448 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45,
    Original PDF
    dilm32
    Type: ZB32−6 Article No.: 278450 Ordering information Overload release, min. – max. Ir A 4–6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55
    Original PDF
    zb12
    Type: ZB12−2,4 Article No.: 278437 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    zb12
    Type: ZB12−1,6 Article No.: 278436 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF