Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SDAINLM16 Search Results

    SF Impression Pixel

    SDAINLM16 Price and Stock

    Eaton Corporation

    Eaton Corporation SDAINLM16(24VDC)

    Star-delta; 7.5kW; 16A; 24VDC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM16(24VDC) 1
    • 1 $465.65
    • 10 $432.39
    • 100 $432.39
    • 1000 $432.39
    • 10000 $432.39
    Get Quote

    Eaton Corporation SDAINLM16(230V50HZ,240V60HZ)

    Star-delta; 7.5kW; 16A; 230÷240VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM16(230V50HZ,240V60HZ) 1
    • 1 $409.02
    • 10 $379.80
    • 100 $379.80
    • 1000 $379.80
    • 10000 $379.80
    Get Quote

    Eaton Corporation SDAINLM16(400V50HZ)

    Star-delta; 7.5kW; 16A; 400VAC; screw terminals
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME SDAINLM16(400V50HZ) 1
    • 1 $448.11
    • 10 $419.30
    • 100 $419.30
    • 1000 $419.30
    • 10000 $419.30
    Get Quote

    SDAINLM16 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    ZB12

    Abstract: ZB12-12 Moeller SDAINLM12
    Contextual Info: Type: ZB12−12 Article No.: 278441 Ordering information Overload release, min. – max. Ir A 9 – 12 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-12dilm12diulm12sdainlm12+7sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12moeller sdainlm12 PDF

    DILM9-10

    Abstract: 1 phase contactor sdainlm16 DILM9-01 delta wiring for a motor DILM7 contactor OVERLOAD RELAY
    Contextual Info: Type: SDAINLM16 110V50HZ,120V60HZ Article No.: 278308 AC operation Ordering information Rated operational current AC−3 400 V Ie A 16 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 4 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V


    Original
    sdainlm16110v50hz120v60hzdilm9-10+8dila-xhi20dilm9-01d-53115hpl-c2006gb-int1 phase contactordelta wiring for a motordilm7 contactoroverload relay PDF

    ZB12

    Abstract: ZB12-10
    Contextual Info: Type: ZB12−10 Article No.: 278440 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-10dilm12diulm12sdainlm12+6sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12 PDF

    DILM9-10

    Abstract: SDAINLM16 230V50HZ DILM9 motor rating for star delta DILM9-01 DILM7 contactor 230v CONTACTOR
    Contextual Info: Type: SDAINLM16 230V50HZ,240V60HZ Article No.: 278311 AC operation Ordering information Rated operational current AC−3 400 V Ie A 16 Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 4 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V


    Original
    sdainlm16230v50hz240v60hzdilm9-10+8dila-xhi20dilm9-01d-53115hpl-c2006gb-intdilm9motor rating for star deltadilm7 contactor230v contactor PDF

    ZB12

    Abstract: SDAINLM22 DIULM12
    Contextual Info: Type: ZB12−1 Article No.: 278435 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-1dilm12diulm12sdainlm12+6sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12 PDF

    ZB12

    Abstract: ZB12-4
    Contextual Info: Type: ZB12−4 Article No.: 278438 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-4dilm12diulm12sdainlm12+6sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12 PDF

    ZB12

    Abstract: ZB12-6
    Contextual Info: Type: ZB12−6 Article No.: 278439 Ordering information Overload release, min. – max. Ir A 4–6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 Short−circuit protection Type “1” coordination


    Original
    zb12-6dilm12diulm12sdainlm12+6sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12 PDF

    ZB12-2

    Abstract: ZB12
    Contextual Info: Type: ZB12−2,4 Article No.: 278437 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-2dilm12diulm12sdainlm12+6sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12 PDF

    ZB12

    Abstract: ZB12-16
    Contextual Info: Type: ZB12−1,6 Article No.: 278436 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22


    Original
    zb12-1dilm12diulm12sdainlm12+7sdainlm16sdainlm22dc-13d-53115hpl-c2005gb-intzb12zb12-16 PDF

    moeller DIL 3M

    Abstract: DILM150-XMV dilm80 PKZM4-63 PKZM04 Moeller dil 2m DILM15-10 moeller dil m17 PKZM0-25 PKZM0-32
    Contextual Info: : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors


    Original
    moeller dil 3mdilm150-xmvdilm80pkzm4-63+6pkzm04moeller dil 2mdilm15-10moeller dil m17pkzm0-25pkzm0-32 PDF

    ZB12-16

    Abstract: Moeller SDAINLM12 SDAINLM22 DIULM12 DILM7 moeller VDE 0660 sdainlm16 failure rate moeller IEC 60947 VDE 0660 NFEN60947-2 1545D
    Contextual Info: Type: ZB12−16 Article No.: 290168 Phase failure sensitivity to IEC/EN 60947 For direct mounting Ordering information Overload releases Ir A 12 – 16 Auxiliary contacts N/O = Normally open 1 N/O Auxiliary contacts N/C = Normally closed 1 N/C For use with


    Original
    zb12-16dilm12dilm15diulm12+12sdainlm12sdainlm16sdainlm22dc-13d-53115hpl-c2006gb-intmoeller sdainlm12dilm7 moellervde 0660failure rate moelleriec 60947 vde 0660 nfen60947-21545d PDF

    DILM15-01

    Abstract: DIL M50 moeller dil m17 moeller dil Moeller dil 2m moeller DIL 3M PKZM 1-10 PKZM4-50 MOELLER PKZM PKZM0-25
    Contextual Info: : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors


    Original
    dilm15-01dil m50moeller dil m17moeller dil+6moeller dil 2mmoeller dil 3mpkzm 1-10pkzm4-50moeller pkzmpkzm0-25 PDF

    star delta starter diagram

    Abstract: DILM7-10 DILM9-10 DILM17-10 DILM25-10 DILM32-10 DILM7-01 DILEM-01 wiring diagram star delta starter DILM32
    Contextual Info: Ordering Star-delta starter combinations Ordering Star-delta starter combinations Contactor combinations SDAINL Moeller HPL0211-2007/2008 Rated operational current AC-3 Max. rating for three-phase motors, 50 – 60 Hz 380 V 400 V 380 V 400 V Ie 220 V 230 V


    Original
    hpl0211-2007/2008sdainlm55230v50hzdilm32-10+12dila-xhi20dilm32-01dilm25-01star delta starter diagramdilm7-10dilm9-10dilm17-10dilm25-10dilm7-01dilem-01wiring diagram star delta starterdilm32 PDF

    star-delta starting motors

    Abstract: Moeller P1-32 moeller dol starters T5B-4-15682 T3-4-15682 p1-32 i2 svb moeller SDAINLM70 SDAINLM115 dol starter ip65 Moeller SDAINLM12
    Contextual Info: www.moeller.co.uk Enclosed Motor Starters & Isolators Short Form Catalogue A We keep power under control. 2 Enclosed motor starters and isolators Contents Contents Enclosed motor starters Direct-on-line – compact 3 4 Direct-on-line – insulated enclosures


    Original
    21-270gbstar-delta starting motorsmoeller p1-32moeller dol starters+7t5b-4-15682t3-4-15682p1-32 i2 svb moellersdainlm70sdainlm115dol starter ip65moeller sdainlm12 PDF

    SDAINLM140

    Abstract: ZB65-XEZ ZB150 thermal relay 220 V VDE 0660 DILM170 SDAINLM200 SDAINLM165 DILM115 DILM150 DILM80
    Contextual Info: Type: ZB150−150 Article No.: 278466 Sales text Overload relay 120−150 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 120.150 Auxiliary contacts N/O = Normally open


    Original
    zb150-150dilm80dilm95dilm115+12dilm150dilm170diulm80diulm95diulm115diulm150sdainlm140zb65-xezzb150thermal relay 220 v vde 0660sdainlm200sdainlm165 PDF

    27-8461

    Abstract: DILM115 DILM150 DILM170 DILM80 ZB150 EN 60947 VDE 0660 SDAINLM140 SDAINLM165 ZB65-XEZ
    Contextual Info: Type: ZB150−35 Article No.: 278461 Sales text Overload relay 25−35 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 25.35 Auxiliary contacts N/O = Normally open


    Original
    zb150-35dilm80dilm95dilm115+12dilm150dilm170diulm80diulm95diulm115diulm15027-8461zb150en 60947 vde 0660sdainlm140sdainlm165zb65-xez PDF

    moeller IEC EN 60947 VDE 0660

    Abstract: DILM170 DILM80 EN 60947 VDE 0660 DILM115 DILM150 ZB150 SDAINLM200 ZB65-XEZ SDAINLM165
    Contextual Info: Type: ZB150−125 Article No.: 278465 Sales text Overload relay 95−125 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 95.125 Auxiliary contacts N/O = Normally open


    Original
    zb150-125dilm80dilm95dilm115+12dilm150dilm170diulm80diulm95diulm115diulm150moeller iec en 60947 vde 0660en 60947 vde 0660zb150sdainlm200zb65-xezsdainlm165 PDF