Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DILM9 Search Results

    DILM9 Datasheets (2)

    Moeller
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    DILM9
    Moeller RC-suppressor Original PDF 139.6KB 2
    DILM9
    Moeller RC-suppressor Original PDF 139.59KB 2
    SF Impression Pixel

    DILM9 Price and Stock

    Eaton Corporation

    Eaton Corporation DILM9-01(24VDC)

    Contactor: 3-pole; NO x3; Auxiliary contacts: NC; 24VDC; 9A; DILM9
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME DILM9-01(24VDC) 20 1
    • 1 $67.38
    • 10 $58.39
    • 100 $58.39
    • 1000 $58.39
    • 10000 $58.39
    Buy Now
    Newark DILM9-01(24VDC) Bulk 12 1
    • 1 $93.58
    • 10 $85.82
    • 100 $76.43
    • 1000 $76.43
    • 10000 $76.43
    Buy Now

    Eaton Corporation DILM9-01(230V50HZ,240V60HZ)

    Contactor: 3-pole; NO x3; Auxiliary contacts: NC; 230VAC; 9A; DILM9
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME DILM9-01(230V50HZ,240V60HZ) 13 1
    • 1 $46.59
    • 10 $40.38
    • 100 $40.38
    • 1000 $40.38
    • 10000 $40.38
    Buy Now
    Newark DILM9-01(230V50HZ,240V60HZ) Bulk 1
    • 1 $87.24
    • 10 $79.06
    • 100 $69.17
    • 1000 $69.17
    • 10000 $69.17
    Buy Now

    Eaton Corporation DILM9-01-EA(230V50HZ,240V60HZ)

    Contactor: 3-pole; NO x3; Auxiliary contacts: NC; 230VAC; 9A; DILM9
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME DILM9-01-EA(230V50HZ,240V60HZ) 9 1
    • 1 $38.33
    • 10 $33.22
    • 100 $33.22
    • 1000 $33.22
    • 10000 $33.22
    Buy Now

    Eaton Corporation DILM95-XSPR240

    Surge arrester; RC element; 110÷240VAC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME DILM95-XSPR240 9 1
    • 1 $36.99
    • 10 $32.28
    • 100 $32.28
    • 1000 $32.28
    • 10000 $32.28
    Buy Now

    Eaton Corporation DILM95-XSPR48

    Surge arrester; RC element; 24÷48VAC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME DILM95-XSPR48 8 1
    • 1 $36.99
    • 10 $32.28
    • 100 $32.28
    • 1000 $32.28
    • 10000 $32.28
    Buy Now

    Documents mentioning DILM9

    Document Partial File Text Tags Type PDF
    xspr240
    Type: DILM95−XSPR240 Article No.: 281206 Sales text RC−suppressor f. DILM40..95 Ordering information Voltage For use with Us V 110 – 240 AC DILM40 – DILM95 DILMP63 DILMP80 Contact sequence Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
    Original PDF
    dilmp63
    Type: DILM95−XSPR48 Article No.: 281205 Sales text RC−suppressor f. DILM40..95 Ordering information Voltage For use with Us V 24 – 48 AC DILM40 – DILM95 DILMP63 DILMP80 Contact sequence Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
    Original PDF
    dilm95
    Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Screw terminals Description 3 pole Description Springloaded terminals on the auxiliary and control circuit terminals Rated operational current
    Original PDF
    Type: DILM9−10(110V50HZ,120V60HZ) Article No.:
    Type: DILM9−10(110V50HZ,120V60HZ) Article No.: 276687 Ordering information Rated operational current AC−3 400 V Ie A Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V 9 P kW 2.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    zb12
    Type: ZB12−12 Article No.: 278441 Ordering information Overload release, min. – max. Ir A 9 – 12 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    Type: DILM9−10(24V50HZ) Article No.: 276677
    Type: DILM9−10(24V50HZ) Article No.: 276677 Ordering information Rated operational current AC−3 400 V Ie A Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V 9 P kW 2.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V P kW 4
    Original PDF
    Type: DILM9−10(24VDC) Article No.: 276705
    Type: DILM9−10(24VDC) Article No.: 276705 Ordering information Rated operational current AC−3 400 V Ie A Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 2.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V P kW 4 Max. rating for three−phase motors, 50 – 60 Hz AC−3
    Original PDF
    dilm95
    Type: DILM95−XSPR500 Article No.: 281207 Sales text RC−suppressor f. DILM40..95 Ordering information Voltage For use with Us V 240 – 500 AC DILM40 – DILM95 DILMP63 DILMP80 Contact sequence Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
    Original PDF
    dilm
    Type: DILM95−XSPVL48 Article No.: 281224 Sales text Varistor−suppressor with LED f. DILM40.. Ordering information Voltage For use with Us V 24 – 48 AC DILM40 – DILM95 DILMP63 DILMP80 Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
    Original PDF
    zb12
    Type: ZB12−10 Article No.: 278440 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    dilm95
    Type: DILM95−XSPVL240 Article No.: 281225 Sales text Varistor−suppressor with LED f. DILM40.. Ordering information Voltage For use with Us V 130 – 240 AC DILM40 – DILM95 DILMP63 DILMP80 Notes concerning the product group For AC−operated contactors 50 – 60 Hz.
    Original PDF
    Type: DILM95(110V50HZ,120V60HZ) Article No.:
    Type: DILM95(110V50HZ,120V60HZ) Article No.: 239477 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Screw terminals Description 3 pole Description Springloaded terminals on the auxiliary and control circuit terminals Rated operational current
    Original PDF
    zb12
    Type: ZB12−1 Article No.: 278435 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    zb12
    Type: ZB12−4 Article No.: 278438 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    zb12
    Type: ZB12−6 Article No.: 278439 Ordering information Overload release, min. – max. Ir A 4–6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 Short−circuit protection Type “1” coordination
    Original PDF
    Type: DILM95(240V50HZ) Article No.: 239469 Sales
    Type: DILM95(240V50HZ) Article No.: 239469 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Screw terminals Description 3 pole Description Springloaded terminals on the auxiliary and control circuit terminals Rated operational current
    Original PDF
    zb12
    Type: ZB12−2,4 Article No.: 278437 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    440v60hz
    Type: DILM9−10(400V50HZ,440V60HZ) Article No.: 276692 Ordering information Rated operational current AC−3 400 V Ie A Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V 9 P kW 2.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    zb12
    Type: ZB12−1,6 Article No.: 278436 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22
    Original PDF
    Type: DILM9−10(230V50HZ,240V60HZ) Article No.:
    Type: DILM9−10(230V50HZ,240V60HZ) Article No.: 276690 Ordering information Rated operational current AC−3 400 V Ie A Max. rating for three−phase motors, 50 – 60 Hz AC−3 230 V P kW 2.5 Max. rating for three−phase motors, 50 – 60 Hz AC−3 400 V
    Original PDF
    : Efficient solutions for motor control The
    : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors
    Original PDF
    zb12
    Type: ZB12−16 Article No.: 290168 Phase failure sensitivity to IEC/EN 60947 For direct mounting Ordering information Overload releases Ir A 12 – 16 Auxiliary contacts N/O = Normally open 1 N/O Auxiliary contacts N/C = Normally closed 1 N/C For use with
    Original PDF
    contactor
    www.moeller.co.uk Industrial Switchgear Short Form Catalogue 2005/2006 Think future. Switch to green. Moeller – Market leaders in industrial switchgear Moeller has been at the forefront of switching, protecting and controlling motors for over 100 years. Setting standards with DIL contactors and PKZ
    Original PDF
    : Efficient solutions for motor control The
    : Efficient solutions for motor control The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. DIL contactors Product information DIL M motor contactors
    Original PDF
    sdainl moeller
    Ordering Star-delta starter combinations Ordering Star-delta starter combinations Contactor combinations SDAINL Moeller HPL0211-2007/2008 Rated operational current AC-3 Max. rating for three-phase motors, 50 – 60 Hz 380 V 400 V 380 V 400 V Ie 220 V 230 V
    Original PDF