| rxig 21 | ABB ASEA B R O W N BO V E RI A66 Relavs Abstract Application -------------------------------------------------------------------- — ---------------------------------------- — IT Type RXIG 21 B03-2032Ey I Instantaneous ac over- and undercurrent relays |
OCR Scan | ||||
| rxig 21 | A IIII | l | | l l ASEA BROWN BOVERI Instantaneous or definitetime ac overcurrent relay assemblies (RXIG 21, 22, 28) B03-2035E ^ ; 1989 Data subject to change without notice ABB Relays (830504) Abstract Application • Single-phase, two-phase or three-phase |
OCR Scan | ||||
| asea | H4k »>1 l1l ASEA BROWN BOVERI ABB Relays Abstract v Application ---------------------- Type RXIG 22…i . . Harmonic desensitized instantaneous ac over- and undercurrent relays i Data subject to change without notic • 0.01 to 1.5 A total range for 6 models |
OCR Scan | ||||
| current relay data table b03-2003e | A H II /■ M IR A S E A B R O W N B O VE R I Current relay data table B03-2003E January 1987 Changed since January 1985 Data subject to change without notici ABB Relays Undercurrent relays Static Electromechanic.' RXIG 21 -2032E 50-60 Hr RXIG22 - ?011B" 5 0 -6 0 H ? |
OCR Scan | ||||
| rxig 2 | AS EA Catalogue RK 4110 E Instantaneous measuring relays for a.c. I type RXIG 2 and RXEG 2 * Measuring circuits built-up of static components r Settsbie i^sximum and rjinim iim op^ralion in th t same re lav * W ide 9 ta le range with ratiif o f 1:3 ■» S tepless setting of op erating value |
OCR Scan | ||||
| Type RXIG •A BROWN BOVER* 1MDB09004-EN Page 1 M a | Type RXIG •A BROWN BOVER* 1MDB09004-EN Page 1 M a rc h 1992 Current relay and protection assemblies Changed since August 1990 D a ta s u b je c t to ch a n g e w ith o u t n o tic e ABB Network Control & Protection “C r t J t v 1 .t u rt / r r v r r c it i t « / t n t o i t rv rrt j f K J i i w t f i l i ö t n tw |
OCR Scan | ||||
| C a ta lo g u e R K 4 1 - 1 4 E EcHlCKil 1360-07 | C a ta lo g u e R K 4 1 - 1 4 E EcHlCKil 1360-07 F il* R, p a rt 1 o Over and undercurrent a.c. relay type RXIG 2 The- R JÎIG 2 c u t r t n i re la y t» ¡¿«I lo -op e rile - lo r e ith e r ovencur” enL or urKter-surrgnt. T h e re la y ha a v a ila b le in th ro e v e rs io n s surisW a for u s a In |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| A lI » ABB Relays Abstract B03-9131I e Type | A lI » ABB Relays Abstract B03-9131I e Type RXTBEA 2 Page 1 January 1987 symmetrical components • Measuring negative or positive sequence voltage Q <K Application The RXTBEA 2 voltage filter is used for measur ing or controlling the negative or positive se |
OCR Scan | ||||
| radss | V ASEA Inform ation RADSS Bus Differential Protection RFF-April J.2I5, RF 657-105 with sensitive Earth-Fault relays — INTRODUCTION In a resistance earthed network the available E/F current is normally less than the full-load current of the largest feeder. |
OCR Scan | ||||
| asea | A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay |
OCR Scan | ||||
| rxil 2 | M IP II ASEA BROWN BOVERI ABB Relays Abstract V Application -- Type RXIL 20 Electromechanical instantaneous ac and dc undercurrent relays B03-2011E w • 0.01 to 20 A total range for 9 models • High accuracy: ± 2 % consistency of operating value ± 3 % graduation error |
OCR Scan | ||||
| rxil 2 | _a t » M W ASEA BROWN BOVERI Types RXIL 23, 24 ABB Relays Abstract K B03-2013E Page 1 January 1987 Electromechanical instantaneous ac and dc overcurrent relays Changed since June 1982 Data subject to change without notic • 2.5 mA to 20 A total range for 10 RXIL 23 |
OCR Scan | ||||
| rxil 2 | Il il li f*lplp ASEA BROWN BOVERI ABB Relays Type RXIL 22 Harmonic desensitized electromechanical instantaneous ac overcurrent relay Abstract 0.01 to 20 A total range for multiple mod els High accuracy: ± 2 % consistency of operating value ± 3 % graduation and setting error |
OCR Scan | ||||
|
|
||||||
| brown boveri | Ali ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGEA 100 % generator stator ground-fault relay • Complete ground-fault protection for gen erator stators that are high impedance grounded • Monitors integrity of the neutral grounding and associated wiring |
OCR Scan | ||||
| ASEA Catalogue RK 65-16 E Edition 1 Single-phase | ASEA Catalogue RK 65-16 E Edition 1 Single-phase overcurrent protective relays Used primarily as earth-fault pro tection. Static or electro-mechanical current relays. Different versions with respect to tripping and Indication, Contents Page General 2 Design |
OCR Scan | ||||
| ASEA Voltage filter type RXTBEB 4 for symmetrical | ASEA Voltage filter type RXTBEB 4 for symmetrical components Catalogue RK 73-16 E Edition 1 September 197? File Rf P a rti Cio M B 1 ' F L e xr* (90aeâ) A S E A Introduction RXTBEB 4 is a three-phase voltagecomponent filter built up of resistors and reactors. The characteristic feature of |
OCR Scan | ||||
| asea | Info-No. ASEA INFORMATION Relay Division RFR Edition 1 RFR 1114 E From/Date Reg. Nov. 1970 Page 5620 1 Pci.890 400 Measuring relays for current and voltage This is a preliminary publication, based on information to be included in Pamphlet RK 4 0 -2 0 1 E. |
OCR Scan | ||||
| shunt reactor | Ulfa-No. INFORMATION From'Date RF 620-003 E Reg. RFA, im - 1 0 - 1 2 Edition 1 ASEA RELAYS Page 1 Shunt reactor protection General Fixed reactors are used in HV and EHV systems to lim it the overvoltages due to capacitive VAr generation in cables and -long overhead lines. |
OCR Scan | ||||
| RAYA Voltage regulating relay for tap changer | RAYA Voltage regulating relay for tap changer control 1MRK 504 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE 84 05 42) Features • Accurate regulation of tap-changers • Inverse or definite time delay • Undervoltage and overcurrent blocking |
Original | ||||
| ASEA B RO W N BOVERI Type RAYA B03.5210 Voltage | ASEA B RO W N BOVERI Type RAYA B03.5210 Voltage regulating relay for Page 1 January 1985 Changed since May 1983 Data subject to change without noti t r a f lS f O r iT IG r S ABB Relays Abstract Application • Accurate regulation of tap changers • Parallel control of two or more power |
OCR Scan | ||||
| ragpc | Gil» Mil» ASEA BROWN BOVERI ABB Relays Abstract Application Design Type RAGPC B03-4013E Loss-of-excitation relay for . , synchronous generators Changed since January 1985 Data subject to change without notice » ■ • Alarm for underexcitation and trip for lossof-excitation |
OCR Scan | ||||
| A SEA Catalogue RK 65-15 E Edition 1 Juno 1975 | A SEA Catalogue RK 65-15 E Edition 1 Juno 1975 Fite R, Part 1 ClOIMIBl I I JL i J l i v r w FlLlElX Two-phase delayed overcurrent t protective relays * used prim arily as a short-circuit p r o taction in networks which are not directly earthed Contents General |
OCR Scan | ||||
| Catalogue RK 82-10 E ASEA Edition 2 March 1975 | Catalogue RK 82-10 E ASEA Edition 2 March 1975 File R, Part 1 Voltage regulating relay type RAYA [cIoImIbTT Inverse or independent time-lag characteristics can be chosen with a change-over switch Undervoltage blocking is adjustable between 70 and 90 % of the rated |
OCR Scan | ||||
| rvab | JL' |fc I t 1 B RK 487-300 E Pago 1 5627 INFORMATION A S ea b r o w n B o v tR i F fo n V D a te .n n „ , A B B Relays RFR, March 1373 Edition 1 Reg, ■Thermal overload relay type RVAB To avoid overloading of a machine, transformer or cattle, a thermal over-current relay can te used to initiate |
OCR Scan | ||||