    RXMVB 2

    Abstract: rxmvb abb 1MRK 251 270 ohm resistor 015-UEN RK 251 204 RXMVB4 595-AD 016-BEN bistable impulse relay
    Text: Bistable relays RXMVB 2 , RXMVB 4 1MRK 508 016-BEN Page 1 Issued: July 2007 Revision: C Data subject to change without notice RXMVB 2 Features (SE970872) RXMVB 4 · Ac or dc voltage , RXMVB 2 available · Position indication Application The RXMVB relay is used in lockout , the dc relay can be used. For RXMVB 2 the diode is connected to 111(+) - 121(-) and 221(+) - 211(- , be ordered. A red flag can be added to RXMVB 2 as an option. Bistable relays RXMVB 2 , RXMVB


    Original
    PDF 016-BEN SE970872) SE970878) 086-A 0086-B 0086-C 268-C 001-BEN 015-UEN SE-721 RXMVB 2 rxmvb abb 1MRK 251 270 ohm resistor 015-UEN RK 251 204 RXMVB4 595-AD 016-BEN bistable impulse relay

    RXMVB2

    Abstract: RXMVB4 RXMVB RXMVB 2 asea contactors asea relay RI Relay RXMVB2 asea ri 5A relay MR 31 relay RK251
    Text: ASEA Catalogue RK 25-10 E Edition4 March 197e Filefl.Partí Throw-over relays type RXMVB 2 and , voltage). ¡91 SOS) ASEA Design and mode of operation The RXMVB 2 and RXMVB 4 throw-over relays are of , rated voltage, d.c. 2.5 W 4 W a.c, 13VA 13 VA Operating times RXMVB 2 RXMVB4 On d.c.,for make contacts , d.c. railage; RXMVB 2 Rated vallate, v 54 43 is 110 125 2£0 2SO Letter cod e AD AH AK AN AP AS AT , AS AT Selection table tor a.c, voltage, 50-60 Hz; RXMVB 2 and RXMVB 4 Rated wlisgft V 24 55 110-1 Â


    OCR Scan
    PDF S-721 RXMVB2 RXMVB4 RXMVB RXMVB 2 asea contactors asea relay RI Relay RXMVB2 asea ri 5A relay MR 31 relay RK251

    RK 251 204

    Abstract: BROWN BOVERI Relay manual rxmvb RXMVB 2 BROWN BOVERI relay differential abb s 212 900-XE latching relay B03-1503E V121
    Text: | ¡1II Type RXMVB 2 bo3-isioe ^^ItJSP Heavy-duty latching relay, S^«,« ASEA BROWN BOVERI g , heavy-duty contacts: no or nc • Cutoff contact for each coil • Position indication (820261) The RXMVB 2 , contact refer to type RXMVB 4. Design The RXMVB 2 is a 8 contact heavy-duty permanent-magnet latching , latching relay data table B03-1503E. To order Specify: , Type RXMVB 2 . Quantity . Ordering no. (consists , under Case dimensions and mounting i structions ABB Relays Type RXMVB 2 B03-1510E Heavy-duty latching


    OCR Scan
    PDF 900-XC 900-XD 900-XE B03-1503E B03-9382E B03-0331E B03-1511E S-721 RK 251 204 BROWN BOVERI Relay manual rxmvb RXMVB 2 BROWN BOVERI relay differential abb s 212 900-XE latching relay V121

    rxmvb

    Abstract: RXMVB 2 RK 251 204 rk251 1MDB14003-EN 2U12C rxmvb2 4U12C ABB RXMVE1 RXMVB4
    Text: subject to change without notice ABB Network Control & Protection RXMVB 4 (820282) RXMVB 2 (820261) RXMVE , circuits against transients a diode unit across the coils of the dc relay can be used. For RXMVB 2 the , can be ordered. Technical data Type ac or dc operated RXMVB 2 dc 50-60 Hz RXMVB 4 dc 50-60 Hz RXMVE1 , *s Type RXMVB 2 RXMVB 4 RXMVE 1 Breaking capacity dc L/R < 40 ms Un = 24 V A 48 V A 110 V A 125 V A , separate delivery Relay type Push button position Ordering No. RXMVB 2 Right and left 5283 0086-A Right -B


    OCR Scan
    PDF 1MDB08004-EN 086-A 1MDB14003-EN rxmvb RXMVB 2 RK 251 204 rk251 2U12C rxmvb2 4U12C ABB RXMVE1 RXMVB4

    relay busbar

    Abstract: RADSS relay rd3 wiring diagram earth fault relay with 4 ct detect RS -24V RELAY ct307 RXME 18 RK 637-104E 505 008-ben 637-300E
    Text: an auxiliary latching relay RXMVB 2 . This is manually reset. The SR element may be set to coincide , RXMVB 2 auxiliary latching relay 101 RTXP 18 RQBA 04 RQDA 04 B1. B7 Test switch Line diode , Closed 325 RXMVB 2 CT open-circuit blocking 113 RXMT 1 ABX, DBX Fig. 7 The main H.V , lamp 2 -RXKL 1 time lag relays 2 -RXMM 1 aux. relay 1- RXMVB 2 aux. blocking relay 1-RXME 1 aux. relay , : 4U RXMVB 2 latching relay RXMM 1 auxiliary relay Bus interconnection (two-zone to one-zone


    Original
    PDF 008-BEN 637-300E 637-104E 637-101E 637-102E 637-105E 637-301E 637-302E 05003-EN 011-BEN relay busbar RADSS relay rd3 wiring diagram earth fault relay with 4 ct detect RS -24V RELAY ct307 RXME 18 RK 637-104E 505 008-ben 637-300E

    asea relay RI

    Abstract: RXEG 2 ASEA RI RXMVB 2 ASEA rk 651 automatic switch over circuit diagram RXMVB rk 651 ASEA RTXP relay asea relay
    Text: Includes the following; • Test switch type RTXP 13 • Voltage relays type RXEG 2 • Throw-over relay type RXMVB 2 Cat. No. RK 651 232-AA Weight 3.8 kg A i„ _ B PI 22I il' 211 ULÍ it> fîf 2 i , ^ ■ÍI 1D7 119 5« 101 RTXP ia Taar iv/lich Voltage relay 107, 113 RJÍEC 3 307 rXmVb 2 Thiüví-tw&r relay ') ££3 anil 224 are connactBd at 2A 9ftd 110-1Ë5 ÏV4C, Fig. V Diagram 5B51128-AA 2 RK , No. 5651 12S-AA p. 2 Reference publications Th tow-over relay RXMVB 2 Voltage relay RXEG 2 COMBIFLEX


    OCR Scan
    PDF 232-AA G5-29 232-AA 12S-AA SK14-1 S-721 13S1-M asea relay RI RXEG 2 ASEA RI RXMVB 2 ASEA rk 651 automatic switch over circuit diagram RXMVB rk 651 ASEA RTXP relay asea relay

    BROWN BOVERI Relay manual

    Abstract: RXMVB latching relay B03-1503E rk 251 401-ad BROWN BOVERI relay differential RK 403 RXMVB 2 ASEA brown boveri protection relay brown Boveri diode
    Text: existing and future contact needs. This compact relay is recommended where the 8 contact RXMVB 2 does not , RXMVB 4 Heavy-duty latching relay, 14 contacts B03-1511E Page 2 To order Specify: • Type RXMVB 4 , relay data table Dimension List of symbols Type RXMVB 2 B03-1503E B03-9382E B03-0331E B03-1510E 1â , All» ASEA BROWN BOVERI ABB Relays Type RXMVB 4 Heavy-duty latching relay, 14 contacts B03 , hand-reset • 2 stable latched positions • 14 heavy-duty contacts: no or nc • Cut-off contact for each


    OCR Scan
    PDF B03-151111 900-XG 900-XH 900-XF B03-1503E B03-9382E B03-0331E B03-1510E S-721 BROWN BOVERI Relay manual RXMVB latching relay rk 251 401-ad BROWN BOVERI relay differential RK 403 RXMVB 2 ASEA brown boveri protection relay brown Boveri diode

    BROWN BOVERI relay differential

    Abstract: RK637 RK 637-104E RXMVB4 RADSS rxms1 abb RTXP18 B03-6010E differential relay rxmvb2
    Text: ) 301 RXKE1 time delay relay (100 ms) 325 RXMVB 2 blocking relay RTXP18 Test switch A typical high speed , -RXMM 1 aux relay 1- RXMVB 2 aux blocking relay 1-RXME 1 aux relay 543 Space for trip relays F1 'Loose , 101,301 RXMVB 2 latching relay 9 Bus Coupler CT disconnection 30C 101 113 125 325 US 101,113 RXMVB 4 , contacts 107,307: RXMVB 2 latching relay with 6 NO and 2 NC contacts 101,301: RXMS 1 with 6 NO contacts 107 , 's to DA, DB RXMVB 2 5651 131-CA Bus interconnection RXMVB 4, RXSF 1, RXKF 1 5651 131-SA ( 2 -zone to 1


    OCR Scan
    PDF B03-6010E S-721 BROWN BOVERI relay differential RK637 RK 637-104E RXMVB4 RADSS rxms1 abb RTXP18 differential relay rxmvb2

    abb 1MRK 251

    Abstract: Rxmd 1MRK 514 001-BEN RXMVB rxmd 2 RXMVB 2 RK 251 204 rxmb1 bistable impulse relay 984-nn
    Text: The relays are pin compatible with earlier types, for example, RXMVE 1 or RXMVB 2 . The RXMB 1 and RXMB 2 relays are therefor suitable as substitutes and as spare part replacement for RXMVE 1 and RXMVB , particular the DC interrupting rating for the contacts differ from the heavy duty contacts of RXMVB 2 , models are configurable per RXMVB 2 previous contact symbols, see table below: RXMVB 2 RXMD 2 , -nn Note that the RXMD 2 relays are not identically configured like the RXMVB 2 . There are more contacts


    Original
    PDF 017-BEN xx00000532) xx00000621) 003-BEN 001-BEN S-721 abb 1MRK 251 Rxmd 1MRK 514 001-BEN RXMVB rxmd 2 RXMVB 2 RK 251 204 rxmb1 bistable impulse relay 984-nn

    RXMVB

    Abstract: RAICA latching relay RXMVB 2 rxmvb2 RADSS rxtcb1 RHGX raica asea RK 216 RTXP18 ASEA
    Text: rela; performance. Latching relay RXMVB 2 or 4 can be included oi the same pair of apparatus bars as an option. ASEA Type RAÏCA Breaker-failure relay B03-6110E Page 2 Technical data •s Rated current Current , mounting or a type RHGX 12 or 20 case for panel mounting. • Optional latching relay RXMVB 2 , 4 Mounting , RXIB 24 B03-2030E Time-delay relay RXKE 1 B03-1613E Latching relay RXMVB 2 B03-1510E Latching relay , , the 2 timer scheme is recommended so that more frequent, less critical ground faults can be cleared


    OCR Scan
    PDF B03-6110e B03-9510E B03-1213E B03-1215E B03-2030E B03-1613E B03-1510E B03-1511E B03-9132E RXMVB RAICA latching relay RXMVB 2 rxmvb2 RADSS rxtcb1 RHGX raica asea RK 216 RTXP18 ASEA

    rxmb1

    Abstract: RELAY RZ2 SUMMATION current transformer ABB rxtp 18 rxmd 2 current transformer ABB transformers of power station relay rd3 BUSBAR calculation datasheet relay 6 volt
    Text: -EA 4U 301 L1:X1 113: RXMVB 2 latching relay RXMM aux. relay Bus coupler CT disconnection , ) 18C 107 307 4U 101, 301: RXMS 1 with 6 NO contacts 107, 307: RXMVB 2 latching relay with 8 , with RXMM 1 and RXMVB 2 State auxiliary dc voltage in both cases 1MRK 002 650-AA 5651 131-EA Bus coupler CT disconnection relay unit with RXMD 2 , RXMB 1 and RXKL 1 alternative with RXMVB 4 , interconnection unit with RXMD 2 , RXMB1 and RXKL 1 alternative with RXMVB 4, RXSF 1 and RXKL 1 State delayed


    Original
    PDF 006-BEN SE970178) 004-BEN 001-BEN 015-BEN 016-BEN SE-721 rxmb1 RELAY RZ2 SUMMATION current transformer ABB rxtp 18 rxmd 2 current transformer ABB transformers of power station relay rd3 BUSBAR calculation datasheet relay 6 volt

    abb rqda 040

    Abstract: 298-HA RADSS 7451 298-HA RADSS 7451 Brown Boveri SERIES 212 asea ri 5A relay RADSS rqda-040 differential relay ge RXMVB 2
    Text: 2 and 3: The relay contact +501.325:224-223 belongs to an RXMVB 2 blocking relay, which will be , not operate when the RXMVB 2 is in the blocked position. Finally, on sheet number 1 is also indicated , contacts 117-118 of the blocking relay 325 ( RXMVB 2 ) and also via the contacts 17B-17A of the relay test , and energizes the change-over blocking relay 325 ( RXMVB 2 ). This relay operation initiates an alarm , mentioned the RXMVB 2 relay also opens the trip circuit and puts a short on the diff. circuit. The RXMVB 2


    OCR Scan
    PDF 298-HA 37016-AÃ 637016-AB abb rqda 040 RADSS 7451 298-HA RADSS 7451 Brown Boveri SERIES 212 asea ri 5A relay RADSS rqda-040 differential relay ge RXMVB 2

    relay rd3

    Abstract: RELAY RZ2 ABB transformer rxmb1 ABB rxtp 18 abb rxmb1 BUSBAR calculation datasheet REB103 RELAY RZ2 5 ABB RXTUG 22H
    Text: 313 RXKL 1 delayed alarm relay 6C 101 RXMVB 2 latching relay Bus coupler CT , 101, 301: RXMS 1 with 6 NO contacts 107, 307: RXMVB 2 latching relay with 8 make contacts Bus , " Switching line CT relay unit with RXMB 1, RXMD 1 and RXMD 2 alternative with RXMM 1 and RXMVB 2 State , with RXMD 2 , RXMB1 and RXKL 1 alternative with RXMVB 4, RXSF 1 and RXKL 1 State delayed alarm relay , unit with 2 RXMS 1 and 2 RXMVB 2 State auxiliary dc voltage State trip circuits (0/6/12) * see below


    Original
    PDF 007-BEN SE970146) 003-BEN 001-BEN 007-UEN 015-BEN 016-BEN 004-BEN SE-721 relay rd3 RELAY RZ2 ABB transformer rxmb1 ABB rxtp 18 abb rxmb1 BUSBAR calculation datasheet REB103 RELAY RZ2 5 ABB RXTUG 22H

    latching relay

    Abstract: ABB Reverse Power Relay abb relay ABB RXMVE1 b03-1503e B03-1512 rxmvb RXMVB 2 current transformer ABB BROWN BOVERI type s relay
    Text: heavy-duty contacts are required (e.g for current transformer secondary circuits), refc to the type RXMVB 2 (8 contacts) or RXMVB (14 contacts). Design The RXMVE 1 latching relay has a magnetic core made of , table B03-1503E Type RXMVB 2 B03-1510E Type RXMVB 4 B03-1511E Mounting and connection B03 , polarity sensing • 2 stable latched positions *v • 3, 4 or 6 medium- (trip-) duty contacts: no, nc or , -1512E Latching relay, 3, 4 or Pase 2 6 contacts To order S Standard versions—specify: . Type RXMVE 1 . Quantity


    OCR Scan
    PDF B03-1512 B03-9301E B03-1503E B03-1510E B03-1511E B03-9301E B03-9382E B03-0331E S-721 latching relay ABB Reverse Power Relay abb relay ABB RXMVE1 b03-1503e rxmvb RXMVB 2 current transformer ABB BROWN BOVERI type s relay

    relay busbar

    Abstract: abb rqda 040 637-300E ABB SLCE 8 RTXP 18 637-105E ABB SLCE 16 RXKE 1 1MDB05003-EN rxms
    Text: mirror relay (existing) L1:1X, :2X RXMVB 2 auxiliary latching relay 101 RTXP18 Test switch RQBA 04 Line diode unit RQDA 04 Relay unit with start + diff elements B1. B7 Transformer + resistor unit 325 RXMVB 2 , -AB 155: Blanking plate 1-RXMM 1 aux. relay 1- RXMVB 2 aux. blocking relay 1-RXME 1 aux. relay toi ISS , . 5651 131-RA 30C Bus interconnection (two-zone to one-zone) Ordering No. 5651 131-SA 101, 301 RXMVB 2 , : RXMVB 2 latching relay with 8 make contacts (5003-25) 101 107 301 307 101, 301: RXMS 1 with 6 make


    OCR Scan
    PDF 1MDB05003-EN 052-AD 052-AG 052-AC 052-AB 040-BEH 040-BEF 637-300E 637-104E 637-101E relay busbar abb rqda 040 ABB SLCE 8 RTXP 18 637-105E ABB SLCE 16 RXKE 1 rxms

    RXMS1

    Abstract: RXMVB RADSS RK 637-104E 637-300E relay rd3 wiring diagram three phase distribution panel schematic relay busbar one line diagram transformer sf6 circuit breaker
    Text: , :2S Self reset mirror relay (existing) l1:1X, :2X RXMVB 2 auxiliary latching relay 101 RTXP18 RQBA 04 , unit 325 RXMVB 2 113 RXMT 1 ABX, DBX CT open-circuit blocking CT open-circuit measuring relay RXMVB 4 , , 301 RXMVB 2 latching relay 113 RXMM 1 auxiliary relay Bus interconnection (two-zone to one-zone , -AE 18 C 101 107 301 307 4u 101, 301 RXMS 1 with 6 NO contacts 107,307 RXMVB 2 latching relay with 8 make , . ABB Network Partner RADSS Busbar protection 1 R/IRK 505 003-BEN Page 2 Application (cont'd) Fig. 1 One


    OCR Scan
    PDF 003-BEN 1MDB05003-EN 052-AF 052-AE 052-AD 052-AG 052-AC 052-AB 637-300E 637-104E RXMS1 RXMVB RADSS RK 637-104E relay rd3 wiring diagram three phase distribution panel schematic relay busbar one line diagram transformer sf6 circuit breaker

    rxms1

    Abstract: rxtcb1 rxmt1 DR RELAYS ct 4060 RK32 relay coupler with 2 n o contacts S-RElay RXKE 1 differential bus relay
    Text: i 301 = rxke 1 —I- I_ 325: rxmvb 2 br2 101 • rxtcb 1 ■Ü br1: rxmt 107: rxms 1 , 107: rxms1 325= rxmvb 2 r 1 rtxp 18 trip -^-o-— B_BUS Fig 2 . Simplified presentation of RADSS trip , differential protection Permitting one CT core in bus coupler la1 X Tma 'A 2 1B11 b2 bus coupler (k) T , coupler two auxiliary CTs must be used. ASEA. S-721 83 Vastarà r, Sweden RF 637 337 E 2 When a fault , operates within 1.5 ms, maloperation can be prevented. Consider the trip circuit shown in fig. 2 and assume


    OCR Scan
    PDF IK311 S-721 506kA /-33A rxms1 rxtcb1 rxmt1 DR RELAYS ct 4060 RK32 relay coupler with 2 n o contacts S-RElay RXKE 1 differential bus relay

    RXSF1

    Abstract: protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB rxsf-1 ABB RXsf1 RXEG21 ASEA motor brown boveri dc motor
    Text: RXME 1 RXME 18 RXMA 2 RXMM 1 RXMS 1 RXMT1 RXSF1 RXMVB2 RXMVB 4 RXMVE1 RXTCB1 RAKZB RXEB2 RAICB RAÏCA , Electrically reset auxiliary, latching, lockout RXMVB 2 , B03-1510E RXMVB4 -1511E RXMVE 1 -1512E RXMVE1 , RADHD -5013e sensitive (RXPE 4) -3020e (RXIG 21, 28) -2035e Hand reset latching/lockout relays RXMVB 2 -1510e RXMVB 4 -1511e Harmonic, restraint differential, 2 input RADSB -5012e 3 input RADSB -5012e , ac-dc heavy-duty, 8 contacts ac-dc medium-(trip-) duty, 2-7 contacts dc heavy-duty, 2 or 4 contacts dc


    OCR Scan
    PDF B03-0310E -7016e -7017e -2031e -2531e -2011e -2032e -2033e -2034e -2910e RXSF1 protection relay type racic RXIDF 2H RXEL22 ASEA relay - RAKZB rxsf-1 ABB RXsf1 RXEG21 ASEA motor brown boveri dc motor

    RXDSE

    Abstract: Transformer differential protection RADSE asea RADSE BROWN BOVERI relay differential RADSE differential relay transformer ASEA brown boveri protection relay RXDSE43 RXDSE 43 rxmvb
    Text: . Reference Buyer's Guide No. Auxiliary relay type RXMS 1 B03-1213E Latching relay type RXMVB 2 B03 , pickup current • Unrestrained operating time 10-20 ms at 2 times pickup current • Variable percentage , B03-5010E Page 2 Design Four standard versions of the RADSE relay are available, each with or without , 18 test switch permitting complete relay testing from the front. Versions 2 , 3 and 4 differ from the , as required for additional inputs. A latching relay type RXMVB 4 can be added as an option when a


    OCR Scan
    PDF B03-5010E B03-1213E B03-1510E B03-1511E B03-9510E B03-9301E B03-9382E RXDSE Transformer differential protection RADSE asea RADSE BROWN BOVERI relay differential RADSE differential relay transformer ASEA brown boveri protection relay RXDSE43 RXDSE 43 rxmvb

    ASEA relay - unbalance relay

    Abstract: RXMVB rxmvb2 rtxh TM21 637-339E
    Text: 's (TM1, TM21 etc), via the shown contacts LI: 1, : 2 and :3 which in practice belong to RXMVB 2 latching , 6-zone bus installation. The line selector-switches are denoted Ll:l, : 2 and :3 and the bus section , selector switch "b"-contact and a self-reset mirror relay. The AB1X, AC1X etc relays are all of the RXMVB 4 , -721 83 Vâsterà s, Sweden RF 637-339E 2 CT-open Circuit Blocking Consider A12X being closed. If for some


    OCR Scan
    PDF 637-339E ASEA relay - unbalance relay RXMVB rxmvb2 rtxh TM21

    ASEA motor

    Abstract: RXPE40 RXMH-2 RXMK1 ASEA brown boveri protection relay ABB RXMVB2 instantaneous overcurrent relay BROWN BOVERI motor protection relay RXIDF 2H asea directional relay
    Text: transfer relay RXMVB4 -1511E 86 Lockout relay RXMVB 2 -1510E RXMVB 4 -1511E RXMVE1 -1512E 87 , jà ai ii MI9» ASEA BROWN BOVERI Index of IEEE device B03-0312E ABB Relays function nUVTIbers January 1985 J lUIIVllVII IIUIIIMVI W Changed since May 1983 with associated ASEA relays Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay RXKC 2H RXKD , /IEEE C37.2-1979 B03-0312E Page 2 Device number Function Type B03 number 50 s Instantaneous overcurrent


    OCR Scan
    PDF B03-0312E B03-1611E -1612E -1613e -1614e -1610e -8112e -8320e -8321e -3211e ASEA motor RXPE40 RXMH-2 RXMK1 ASEA brown boveri protection relay ABB RXMVB2 instantaneous overcurrent relay BROWN BOVERI motor protection relay RXIDF 2H asea directional relay

    asea contactors

    Abstract: rrmj rrmvb2 ASEA EG 20 rrmv IC 4 pins relay relay busbar 92-1E 2190 relay 14 pins relay base wiring
    Text: RXMVB 2 and RXMVB 4 and are described in Cat. RK 25-10 E. • Manual operation; position indication , ASEA Catalogue RK 12-1 E Edition 2 December 1965 File R, Part 2 Throw-over relays RRMVB 2 and RRMVB 4 • With 8 and 16 contacts respectively, arranged in two groups • 2 contacts are used to cut oft , . operation • RRMVB 2 and RRMVB 4 are plug-in relays occupying 2 or 4 relay seats respectively • Can be , RRMVB 2 not more than 2 per side can be converted and on RRMVB 4 not more than 4 per side. 2 Cat RK 12-1


    OCR Scan
    PDF

    three relay stabilizer circuit diagram

    Abstract: RK 411 RXKL 1 RXIG 22 RHGX rxig 21 rxig 28 generators winding circuit diagrams RXIG 2 RK411
    Text: -CB/ -CBA RK 651 010-CB 3I > RXKL 1 RXMVB 2 7431 0104-BA/ -BAA RK 651 013-BA I 2 , Overcurrent relay and protection RXIG 2 and RAIG 1MRK 509 010-BEN Page 1 Issued December , - and medium-duty trip output · Twelve current ranges provide a total setting range of 2 ,5 mA to 45 A , stage on capacitor banks. A version with release input can be used as stub protection in 11/ 2 CB , RXIG 2 and RAIG 1MRK 509 010-BEN Page 2 Application (cont'd) Earth fault protection


    Original
    PDF 010-BEN SE970176) SE970889) 004-AB 315-B 315-C 015-BEN 016-BEN 018-BEN three relay stabilizer circuit diagram RK 411 RXKL 1 RXIG 22 RHGX rxig 21 rxig 28 generators winding circuit diagrams RXIG 2 RK411

    RK 891 031-aa

    Abstract: interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec RXME 1 abb rk 216 rk 211 072
    Text: RXMVB 2 RXKL 1 5651 273-CA 5651 260-AA 2 5651 261-D 1 2 5651 261-AA RK 651 231 , Auxiliary, signalling and tripping relays RXMA1, RXMA 2 , RXMM 1 RXMS 1, RXSF 1, RXME 1, RXME 18, RXMH 2 & RXMT 1 RXMM 1 (SE 90 06 16) RXSF 1 (SE 82 02 62) (SE 82 02 62) (SE 94 07 44 , 1 (SE 94 07 42) RXMA 1 Features 1MRK 508 015-BEN RXME 1 RXMH 2 · Suitable for , RXMA 1, RXMA 2 and RXMM 1 are used as position repeat relays, as interposing relays in control


    Original
    PDF 015-BEN 031-AA, 284-AAA 001-BEN 019-BEN 017-BEN 002-BEN 007-BEN 003-BEN RK 891 031-aa interposing relay RK 211 074 RK 211 064 RXMS1 ABB make RED 670 rk 223 069 ec RXME 1 abb rk 216 rk 211 072

    RXMVB

    Abstract: 637-301E fg relay
    Text: will be cleared instantaneously by the correct A-bus differential protection. 2 ) If the fault Fl occurs , CPs, Thereafter, the 101: RXMVB ^ relay disconnects the CT's from the differential relays. A5EA S-721 S3 VUlntl SwMtn RK 637-301 E 2 The same switching sequence will also be initiated by the A- and B-bus , relays 325tRXMM 1 and 101 plus lt3: RXMVB 4 may all be regarded to operate in approximately 25 ms. If , relays at approximately: Time .25 + 25 + 3 + 25 + 25 Relay RXMM 1 RXKB 1 RXMVB if RXMVB 4 Le. at the same