Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RADIATION IONIZING DOS Search Results

    RADIATION IONIZING DOS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    5962-1222402V9A
    Texas Instruments Radiation Hardness Assured (RHA) wide Vin low-dropout voltage regulator 0-XCEPT -55 to 125 Visit Texas Instruments
    5962-1123701VXC
    Texas Instruments 16MB Radiation-Hardened SRAM 76-CFP -55 to 125 Visit Texas Instruments Buy
    SMV512K32HFG
    Texas Instruments 16MB Radiation-Hardened SRAM 76-CFP -55 to 125 Visit Texas Instruments Buy
    5962-1722001VXC
    Texas Instruments Radiation hardness assured 1.5-V to 7-V, 6-A load switch 16-CFP -55 to 125 Visit Texas Instruments Buy
    5962R1722001V9A
    Texas Instruments Radiation hardness assured 1.5-V to 7-V, 6-A load switch 0-XCEPT -55 to 125 Visit Texas Instruments

    Documents mentioning RADIATION IONIZING DOS

    Document Partial File Text Tags Type PDF
    xqr4000xl
    QPRO XQR4000XL Radiation Hardened FPGAs R DS071 (v1.1) June 25, 2000 2 XQR4000XL Series Features • Product Specification • Radiation-hardened FPGAs for space and satellite applications Guaranteed total ionizing dose
    Original PDF
    QPRO XQR4000XL QML Radiation Hardened Field
    QPRO XQR4000XL QML Radiation Hardened Field Programmable Gate Arrays KXILINX Septem ber 28, 1998 Prelim inary Product S pecification XQR4000XL Series Features • - Radiation H ardened FPGAs for space and satellite applications G uaranteed Total Ionizing Dose
    OCR Scan PDF
    qpro virtex 2.5v radiation hardened fpgas
    QPro Virtex 2.5V Radiation Hardened FPGAs R DS028 (v1.2) November 5, 2001 2 Preliminary Product Specification Features • 0.22 µm 5-layer epitaxial process • QML certified • Radiation hardened FPGAs for space and satellite applications • Guaranteed total ionizing dose to 100K Rad(si)
    Original PDF
    mil-std-883
    Comprehensive radiation effects test and support MIL-STD Radiation Effects Test Services n Total Ionizing Dose (TID) RLAT (50 to 300 rads/sec) – MIL-STD-883 TM 1019, Cond. A n TID ELDRS (10 to 100 mrads/sec) – MIL-STD-883 TM 1019, Cond. D, ESA/SCC22900
    Original PDF
    hsn-3000
    MAXWELL LABS IN C / S-CUBED 37E D 507=1721 HMnaauL 0000042 1 SCUB - 65-13 S-CUBED Division RADIATION HARDENED HYBRID NUCLEAR EVENT DETECTOR Model HSN-3000 FEATURES • Detects ionizing radiation pulses • 100% tested/certified detection threshold level • Adjustable circumvention period
    OCR Scan PDF
    MAXWELL LABS IN C / S-CUBED 37E D 507=1751
    MAXWELL LABS IN C / S-CUBED 37E D 507=1751 Q0Q0G4Q S H S C U B T -6 5 'íZ S-CUBED Division RADIATION HARDENED HYBRID NUCLEAR EVENT DETECTOR Model HSN-1000 FEATURES • Detects ionizing radiation pulses • Tested/certified detection threshold level • Adjustable circumvention period
    OCR Scan PDF
    N Total Ionizing Dose Radiation Data (krads,
    N Total Ionizing Dose Radiation Data (krads, typical) 10 30 50 Analog CMOS Op Amps Bipolar Op Amps Comlinear Comparators Data Acquisition References Regulators Low Dropout Voltage Regulators Motor Drivers Phased Lock Loops (PLL) ASIC CMOS Gate Array (.65µm)
    Original PDF
    Preliminary v1.1 RadTolerant RAD-PAK® Field
    Preliminary v1.1 RadTolerant RAD-PAK® Field Programmable Gate Arrays Features Radiation Characteristics • RAD-PAK® Package Technology from Space Electronics, Inc. • Improved Total Ionizing Dose (TID) Survivability – Can Improve TID 2-10x Over Standard Package
    Original PDF
    sg137
    SGR137 / SGR137A 1.5 Amp Negative Adjustable Regulator Features Description The SGR137/SGR137A is fit, form and function compatible to the SG137/SG137A with the addition of guaranteed performance after radiation exposure to Total Ionizing Dose (TID), Enhanced Low Dose Rate
    Original PDF
    lm136a-2.5qml
    LM136A-2.5QML www.ti.com SNOSAM3D – JULY 2007 – REVISED OCTOBER 2010 LM136A-2.5QML 2.5V Reference Diode Check for Samples: LM136A-2.5QML FEATURES 1 • 2 • Available with radiation guarantee – Total Ionizing Dose 100 krad(Si) – ELDRS Free 100 krad(Si)
    Original PDF
    ut7q512
    UTMC Application Note _____________________________________________________________ A Radiation Tolerant 4M SRAM for Space Applications Abstract Total ionizing dose and heavy ion single event effects data are presented for a radiation tolerant 100ns 4M SRAM (UT7Q512). The SRAM is shown to be resistant to between 20 and 35krad(Si) of total dose radiation (depending on the particular lot examined) at a relatively high dose rate of 46rad(Si)/s. The SRAM is
    Original PDF
    dose
    ELDRS-Free Bipolar Analog Products national.com/space Enhanced Low Dose Rate Sensitivity It has been shown that for many types of integrated circuits, the response to total ionizing dose (TID) radiation is dependent on the dose rate. Many bipolar products have been shown to exhibit
    Original PDF
    v2.1 SX Family FPGAs RadTolerant and HiRel
    v2.1 SX Family FPGAs RadTolerant and HiRel Features High Density Devices • RadTolerant SX Family • Tested Total Ionizing Dose (TID) Survivability Level Radiation Performance to 100 Krads (Si) (ICC Standby Parametric) Devices Available from Tested Pedigreed Lots
    Original PDF
    lm136a-2.5qml
    LM136A-2.5QML www.ti.com SNOSAM3D – JULY 2007 – REVISED OCTOBER 2010 LM136A-2.5QML 2.5V Reference Diode Check for Samples: LM136A-2.5QML FEATURES 1 • 2 • Available with radiation guarantee – Total Ionizing Dose 100 krad(Si) – ELDRS Free 100 krad(Si)
    Original PDF
    LM139AQML, LM139QML www.ti.com SNOSAH8F –
    LM139AQML, LM139QML www.ti.com SNOSAH8F – FEBRUARY 2005 – REVISED FEBRUARY 2011 LOW POWER LOW OFFSET VOLTAGE QUAD COMPARATORS Check for Samples: LM139AQML, LM139QML FEATURES 1 • 2 • Available With Radiation Guarantee – Total Ionizing Dose 100 krad(Si)
    Original PDF
    LM139AQML, LM139QML www.ti.com SNOSAH8F –
    LM139AQML, LM139QML www.ti.com SNOSAH8F – FEBRUARY 2005 – REVISED FEBRUARY 2011 LOW POWER LOW OFFSET VOLTAGE QUAD COMPARATORS Check for Samples: LM139AQML, LM139QML FEATURES 1 • 2 • Available With Radiation Guarantee – Total Ionizing Dose 100 krad(Si)
    Original PDF
    LM117HVQML www.ti.com SNVS357C – MARCH 2006 –
    LM117HVQML www.ti.com SNVS357C – MARCH 2006 – REVISED SEPTEMBER 2011 LM117HVQML 3-Terminal Adjustable Regulator Check for Samples: LM117HVQML FEATURES 1 • 2 • Available with radiation guarantee – Total Ionizing Dose 100 krad(Si) – Low Dose Rate Qualified 100 krad(Si)
    Original PDF
    v2.1 SX Family FPGAs RadTolerant and HiRel
    v2.1 SX Family FPGAs RadTolerant and HiRel Features High Density Devices • RadTolerant SX Family • Tested Total Ionizing Dose (TID) Survivability Level Radiation Performance to 100 Krads (Si) (ICC Standby Parametric) Devices Available from Tested Pedigreed Lots
    Original PDF