NOX SENSO Search Results
NOX SENSO Result Highlights (2)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| COMBOBODYSENSOR | Texas Instruments | ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications |
|
Documents mentioning NOX SENSO
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| exhaust gas sensor | PRODUT NAME : EXHAUST GAS SENSOR MODEL No. : GSP-EX01 DETECTING GAS : Exhaust gas of autovehicle (NOx and H2 ,,CO, HC etc.) FEATURES Uses Simple electrical circuit High sensitivity to exhaust gas of autovehicle APPLICATIONS For automobile ventilation control |
Original | ||||
| mq-135 | TECHNICAL DATA MQ-135 GAS SENSOR FEATURES Wide detecting scope Fast response and High sensitivity Stable and long life Simple drive circuit APPLICATION They are used in air quality control equipments for buildings/offices, are suitable for detecting of NH3,NOx, alcohol, Benzene, smoke,CO2 ,etc. |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSU This analyzer consists of an infrared gas analyzer, a zirconia O2 sensor and a gas sampling device. It is used for simultaneous and continuous measurement of the NOX, SO2, CO, CO2 and O2 components in the flue gas of various boilers, garbage incinerators, etc. |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSP This instrument consists of an (or two) infrared gas analyzer(s), a zirconia O2 sensor and a sampling device. It is used for measuring the NOx, SO2, CO and O2 components in the flue gas of various boilers, garbage incinerators, furnaces, etc. |
Original | ||||
| A a Si PHOTODIODES r-^tvî-iîMŒ! S-10. Si | A a Si PHOTODIODES r-^tvî-iîMŒ! S-10. Si Photodiode with Built-in Pre-amp (TE-cooledTyp Large area ( 1 0 x 1 0 mm), low noise, high stability The S6204 is a TE-cooled Si photodiode with operational amplifier for lowlight-level detection, e. g. spectrophotometry, NOx sensor. This integrates |
OCR Scan | ||||
| iml-0636 | IML-0636 Search Engine > IML-0636: Dimensions Sensors > Pyroelectric Infrared Sensors > Fresnel Lens All products and company names herein are trademarks or registered trademarks of their respective owners. |TOP| All Rights Reserved, Copyright (c) Murata Manufacturing Co., Ltd. 2005 |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER (5-COMPONENT ANALYZER) DATA SHEET This gas analyzer (ZKJ) is capable of measuring the concentrations of NO, SO 2, CO 2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4 are measured by non-dispersion infrared method (NDIR), while O 2 is measured by built-in |
Original | ||||
| 2006 Site Report ROHM CO., LTD. Domestic Group | 2006 Site Report ROHM CO., LTD. Domestic Group 21,Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585 Japan Fiscal Year Item Electric-power consumption 2004 2005 101,396,000 kwh Fuel consumption 7,563 kl Water consumption 2006 100,219,000 kwh 101,947,000 kwh 6,519 kl |
Original | ||||
| e700st0 | MURATA MANUFACTURING CO.,LTD CUSTOMER :_________________________ DATE 3 -Aprii-1996 SPECIFICATION FOR INFRARED SENSOR MODEL NAME : IRA- E700ST0 PRODUCT ENGINEERING SECTION 2 SENSOR MODULE DEPARTMENT NEW BUSINESS DEVELOPMENT DIVISION MURATA MANUFACTURING CO..LTD. |
OCR Scan | ||||
| so14n | iC-HE TRIPLE DIFFERENTIAL LINE DRIVER ar y n i im prel Rev A1, Page 1/6 FEATURES APPLICATIONS ♦ Complementary short-circuit-proof push-pull driver stages for RS422 and 24 V applications up to 2 MHz ♦ SO14N package pin-compatible to ET9600 ♦ Integrated line adaptation for high signal quality at 24 V |
Original | ||||
| jegi1-0132 | Specification Number : JEGI1-0132 1/8 1. Scope This product specification is applied to dual element type pyroelectric infrared sensor IRA-E710ST0 used to detect infrared rays. Please contact us when using this products for any other applications than described in the above. |
Original | ||||
| 2006 Site Report ROHM KOREA CORPORATION Overseas | 2006 Site Report ROHM KOREA CORPORATION Overseas Group 371-11 Gasan-Dong, Gumcheon-ku, Seoul 153-803 Korea Fiscal Year Item Electric-power consumption 2004 Fuel consumption 183 Thousand m Monolithic ICs, Transistors, Diodes, LEDs, Sensors, Resistors, LED Displays |
Original | ||||
| ira-e900st1 | Specification Number : JEGI1-0133 1/8 1. Scope This product specification is applied to a quad element type pyroelectric infrared sensor IRA-E900ST1 used to detect infrared ray. Please contact us when using this product for any other applications than described in the above. |
Original | ||||
| Thermistor Temperature Sensors (Very high temp. | Thermistor Temperature Sensors (Very high temp. use) Thermistor Temperature Sensors (Very high temp. use) ERTH Type: The miniaturized Temperature Sensor is especially desigined for high temperature detection of heated parts in automobiles and characterized by the wide |
Original | ||||
|
|
||||||
| mgsm3000 | Gas Sensing Microsystem Module PRELIMINARY MGSM3000 Gas Sensing Module with two MSGS3000 Gas Sensors Sensors Interface electronics Communication MSGS1 8-bit Microcontroller ROM Flash D A MSGS2 MCU RAM D A PB UART MAX 232 I/O (LCD) 8 M U X A/D clocks PA PC |
Original | ||||
| advance cemas | Advance Cemas-NDIR Multi component Measuring System for Emission Monitoring and Process Control Specification Sheet 10/23 8.20 EN July 2002 n Complete analyzer system with gas sampling, sample conditioning, analyzer and system control unit in a single cabinet |
Original | ||||
| ic-he | ar y n i lim 3-KANAL-DIFFERENZ-LEITUNGSTREIBER pre iC-HE Ausgabe A1, Seite 1/6 EIGENSCHAFTEN ANWENDUNGEN ♦ Komplementäre, kurzschlussfeste Push-Pull-Treiberstufen für RS422- und 24-V-Applikationen bis 2 MHz ♦ SO14N-Gehäuse kompatibel zu ET9600 ♦ Integrierte Kabelanpassung für hohe Signalqualität bei 24 V |
Original | ||||
| MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET | MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET ZRF This NDIR gas analyzer features a high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high sensitivity and reliability. Being housed in a 19 inch rack case suitable |
Original | ||||
| pollution | Consumer Appliance, Widget, Gadget Personal Ecology Widget Author: This consumer product in some variation, may be used in different areas of human life, such as personal cars, homes, and in the work environment with high levels of pollution emissions, as in mines, chemical |
Original | ||||
| r-29med | TELEDYNE ANALYTICAL INSTRUMENTS Teledyne’s R-29MED is designed for direct replacement of sensors used in Ceramatec’s MAXO2 series of analyzers. This component offers a cost-effective, replacement sensor solution from the company known for its long tradition of providing stable, |
Original | ||||