LPG GAS SENSOR
Abstract: CO Gas sensor gas sensor gas module sensor CO Sensor "Co Sensor" alcohol sensor module Hair Curler LPG GAS SENSOR application basic stamp BS2 ic
Text: CH4 (Methane) Gas Sensor Module (#27930) CO (Carbon Monoxide) Gas Sensor Module (#27931) LPG (Propane , ( CO ). Propane Gas (LPG) can leak from propane grills and furnaces and Methane (CH4) can be found in , Modules (#27930, #27931, #27932, #27904) v2.2 8/2/2010 Page 4 of 6 CO Sensor Specifics The CO gas , , and C2H5OH gas sensors where the heater is on or off. To sense CO gas using the CO gas sensor the , false positives. In order to power the CO gas sensor from 5V and still obtain 1.4 V for the sense phase
|
Original
|
PDF
|
|
CO Gas sensor
Abstract: gas sensor CO flame arrestor GAS SENSOR 100-mesh "Gas Sensor" co gas AF23 thick film gas sensor CO "gas Sensors"
Text: g GAS SENSORS : TYPE AF23 CO GAS SENSOR PROVISIONAL DATA DESCRIPTION: CO gas sensor made , -mesh stainless gauze(SUS316) Dimensions in mm Typical gas sensitivity: Sensitivity characteristics: Specification Sensor resistance Rgas Conditions 15k to 60k 100 ppm CO /air Resistance ratio Gas sensitivity 0.10 to 0.35 at 100ppm CO Rgas/Rair to clean air Power 510mW (nom) consumption Mechanical , shown in the sensitivity characteristics Data sheet D-AF-1 g GAS SENSORS : TYPE AF23 CO GAS
|
Original
|
PDF
|
100ppm
CO Gas sensor
gas sensor CO
flame arrestor
GAS SENSOR
100-mesh
"Gas Sensor"
co gas
AF23
thick film gas sensor CO
"gas Sensors"
|
2008 - Not Available
Abstract: No abstract text available
Text: levels in the air. Features ⢠RealTest⢠technology allows installer to test detector with CO gas , SEMS terminals ⢠A six year end-of-life timer With RealTest⢠technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test , end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a
|
Original
|
PDF
|
CO1224T
CO1224T
800-SENSOR2
A05-0437-000
|
Not Available
Abstract: No abstract text available
Text: been reached or exceeded. ï· ï· ï· ï· CO (Carbon Monoxide) Gas Sensor (#605-00007) CH4 , #27930 â #27932 â #27904 â CO Gas Sensor Module CH4 Gas Sensor Module LPG Gas Sensor Module , . Automotive exhaust and charcoal cooking grill exhausts emit carbon monoxide ( CO ). Propane Gas (LPG) can leak , /2013 Page 3 of 4 CO Sensor Specifics The CO gas sensor must cycle through alternating voltages on , off. To sense CO gas using the CO gas sensor the heater must be driven at 5 V (full power) for the
|
Original
|
PDF
|
|
CO Gas sensor
Abstract: gas sensor CO thick film co gas sensor keystone carbon DAEWOO fax DAEWOO AF23 SUS316 gas sensors
Text: GAS SENSORS : TYPE AF23 CO GAS SENSOR PROVISIONAL DATA DESCRIPTION: CO gas sensor made with , -mesh stainless gauze(SUS316) Dimensions in mm Typical gas sensitivity: Sensitivity characteristics: Specification Sensor resistance Rgas Conditions 15k to 60k 100 ppm CO /air Resistance ratio Gas sensitivity 0.10 to 0.35 at 100ppm CO Rgas/Rair to clean air Power 510mW (nom) consumption Mechanical , : thmkorea@bora.dacom.co.kr GAS SENSORS : TYPE AF23 CO GAS SENSOR NOTES: PROVISIONAL DATA Test conditions
|
Original
|
PDF
|
|
HS-134
Abstract: carbon monoxide sensor HS 134 alcohol sensor data sheet carbon dioxide sensor transistor working principle NOx sensor 3 pin alcohol sensor data sheet propane gas alcohol sensor
Text: signal VRL(measured by using Fig.2 circuit and CO gas concentration. 5 4 3 co 2 H2 , moved form clean air to carbon monoxide ( CO ) gas environment. Those data was measured after heating , Sencera Co . Ltd. Data Sheet Tel:886-2-27046595 Fax:886-2-27041279 justinel@ms14.hinet.net 4F-1 , interference from gases of NOx , Alkane, etc. 2.3 The enveloped HS-134 gas sensitive components have 6 pin, 4 , Min. In 100ppm CO 1 . 5 Min. r e Fig. 4 Dww P ivm.tw ro Dn.c F.zeo In air
|
Original
|
PDF
|
HS-134
carbon monoxide sensor
HS 134
alcohol sensor data sheet
carbon dioxide sensor
transistor working principle
NOx sensor
3 pin alcohol sensor data sheet
propane gas
alcohol sensor
|
carbon monoxide sensor
Abstract: HS-134 alcohol sensor data sheet carbon dioxide sensor HS 134 isobutane gas sensor propane gas NOx sensor Sencera Co., Ltd GAS SENSOR for oxygen
Text: between output signal VRL(measured by using Fig.2 circuit and CO gas concentration. 5 4 3 co 2 H2 1 Alcohol 0 0 100 200 300 400 500 600 700 800 900 ppm Fig.3 l a , the sensor is moved form clean air to carbon monoxide ( CO ) gas environment. Those data was measured , Sencera Co . Ltd. Data Sheet Tel:886-2-27046595 Fax:886-2-27041279 justinel@ms14.hinet.net 4F-1 , from gases of NOx , Alkane, etc. 2.3 The enveloped HS-134 gas sensitive components have 6 pin, 4 of
|
Original
|
PDF
|
HS-134
carbon monoxide sensor
alcohol sensor data sheet
carbon dioxide sensor
HS 134
isobutane gas sensor
propane gas
NOx sensor
Sencera Co., Ltd
GAS SENSOR for oxygen
|
2010 - VZ09
Abstract: norgren Valves Norgren 12F73 herion solenoid 2052 LPSP 3039 norgren NORGREN -HERION festo gas solenoid valve
Text: . current Io Max. power Po Gas group Max. external inductivity Lo Max. external capacity Co Gas group Max. external inductivity Lo Max. external capacity Co Gas group Max. external inductivity Lo Max. external capacity Co Certificates / Approvals (DCS = 0%, DCD = 0%) 27.7 V 101 mA 697 mW II C 5.2 mH 0.08 µF II
|
Original
|
PDF
|
MCR-EX-SL-SD-24-48-LP-SP
IF-2009)
MCR-EX-SL-SD-24-48-LP-SP
VZ09
norgren Valves
Norgren
12F73
herion solenoid 2052
LPSP
3039 norgren
NORGREN -HERION
festo
gas solenoid valve
|
RY7910D
Abstract: WY7211 WY7217 CY7200A1002 Yamatake CO Sensor "Co Sensor" DC24V DC1600 co gas
Text: monoxide transmitter detects levels of the poisonous gas ( CO ) and sends a real-time value to a control , concentration. Because the electric potential at which electrolysis takes place depends on the gas , only CO , Mounting Plate (1.6t) Fig.2 Mounting Plate Dimensions CO Gas Sensor Dimensions(mm) Fixing Screws , affected parts immediately for at least 15 minutes. CO Gas Sensor Fixing Screws Sensor Cover , for the detection of concentration of CO in indoor spaces. Typical applications include detection of
|
Original
|
PDF
|
AB-5782
CY7200A
CY7200A
AB-5782
RY7910D
WY7211
WY7217
CY7200A1002
Yamatake
CO Sensor
"Co Sensor"
DC24V
DC1600
co gas
|
2008 - Not Available
Abstract: No abstract text available
Text: alarm level by choosing one of these available CO gas levels: 25, 30, 35, 45, 50, 70, 100 and 200ppm , Data Sheet CM100 Carbon Monoxide Meter with Adjustable CO Levels The Amprobe CM100 is a compact size CO meter for measuring and displaying the presence of carbon monoxide. The CM100 displays the CO level on its digital display. You can set the meterâs alarm to alert when a CO level goes beyond a predetermined safety level. The CM100 User manual has a chart of published safety levels for CO
|
Original
|
PDF
|
CM100
CM100
CM100â
25ppm
200ppm
to140Â
877-AMPROBE
|
2008 - Not Available
Abstract: No abstract text available
Text: choosing one of these available CO gas levels: 25, 30, 35, 45, 50, 70, 100 and 200ppm No hassle , Data Sheet CM100 Carbon Monoxide Meter with Adjustable CO Levels The Amprobe CM100 is a compact size CO meter for measuring and displaying the presence of carbon monoxide. The CM100 displays the CO level on its digital display. You can set the meterâs alarm to alert when a CO level goes beyond a predetermined safety level. The CM100 User manual has a chart of published safety levels for CO
|
Original
|
PDF
|
CM100
CM100
CM100â
25ppm
200ppm
to140Â
877-AMPROBE
|
TGS203
Abstract: Figaro TGS203 FIGARO ke 25 LV1011 FIC-5401 carbon monoxide ir sensor TGS 832 TCS2113 TGS 832 sensor acetone gas sensor
Text: heaLer voltage conditions tbe sensor for measLi ring CO gas . 1000 Air -aâCH4 *â¡-C4H1 0 CO , to LhaL of CO . W hi Le Rs decreases in CO gas , nitrogen dioxide (NO'l L'aLise^ sensor resistance to , - ^â ii-.lll'.lh' In various gjsts 1 0000 X I Gas : CO 100|=çfn| ÃS s: VVN. NN 0% RH 40% RH 90% RH RH , rse re Iii L Lo nsh Lp o f VEL between CO and alcohol. In CO gas , Lherôà sLarL.s lnurea.slng with , : 0.1 CO + &jppm oF WQ2 H2l C2H5ÃH 10 100 1000 Gas Concentralion (ppmi 1 0000 Figuiy I
|
OCR Scan
|
PDF
|
TGS203
TGS203
Figaro TGS203
FIGARO ke 25
LV1011
FIC-5401
carbon monoxide ir sensor
TGS 832
TCS2113
TGS 832 sensor
acetone gas sensor
|
"Co Sensor"
Abstract: co sensor MSGS-3001 Microsens SA pH schematic 3 phase heater control MSGS-3001-B electric heater temperature SENSOR Microsens SA carbon monoxide sensor Microsens
Text: description MSGS-3001 Integrated semiconductor carbon monoxide ( CO ) gas sensors are manufactured using , Concentration [ppm] Figure 6: CO Sensitivity Ratio RS( gas )/RS(100 ppm CO ; 50%RH) · Avoid to overheat the , Microsens Semiconductor Gas Sensor MSGS-3001 Carbon Monoxide Gas Sensor mechanisms to properly , of MSGS-3001 miniaturized gas sensors presents the advantages of low cost, reproducibility, small , range: 5 to over 1000 ppm CO · Low humidity dependence in recommended operation mode · Stable
|
Original
|
PDF
|
MSGS-3001
CH-2007
"Co Sensor"
co sensor
Microsens SA pH
schematic 3 phase heater control
MSGS-3001-B
electric heater temperature SENSOR
Microsens SA
carbon monoxide sensor
Microsens
|
TGS203
Abstract: Figaro TGS203 Figaro TGS 203 FIC-5401 carbon monoxide sensor acetone gas sensor water level alarm circuit conclusion tgs-203 NOx sensor M Q2 smoke sensor
Text: conditions the sensor for measuring CO gas . Revised 9/99 1000 Air CH4 i-C4H10 CO C2H5OH H2 , in CO gas , nitrogen dioxide (NO2) causes sensor resistance to increase. However, the effect of as , the practical upper sensing limit of the sensor. 100 Gas : CO 100ppm 10 Rs/Ro The amount of , relationship of VRL between CO and alcohol. In CO gas , the RL V starts increasing with the change in heater , 1000 10000 Gas Concentration (ppm) Note: Sensor resistance (Ro) in 100ppm of CO , which is
|
Original
|
PDF
|
TGS203
TGS203
Figaro TGS203
Figaro TGS 203
FIC-5401
carbon monoxide sensor
acetone gas sensor
water level alarm circuit conclusion
tgs-203
NOx sensor
M Q2 smoke sensor
|
|
2012 - EN61508
Abstract: No abstract text available
Text: . current Io Max. power Po Gas group Max. external inductivity Lo Max. external capacity Co Gas group Max. external inductivity Lo Max. external capacity Co Safety-related maximum voltage Um Operation Max. voltage , Bidirectional transmission of digital HART communication signals (both outputs) PHOENIX CONTACT GmbH & Co . KG , mA . 20 mA Approx. 3.9 V PHOENIX CONTACT GmbH & Co . KG http://www.phoenixcontact.com Page 2 , (50 Hz, 1 min., test voltage) CE-compliant, additionally EN 61326 PHOENIX CONTACT GmbH & Co . KG
|
Original
|
PDF
|
IF-2011)
EN61508
|
TGS 800 gas sensor
Abstract: Carbon Monoxide SENSOR CIRCUIT DIAGRAM TGS 800 figaro electrochemical sensor CO TGS5042 carbon monoxide sensor electrochemical sensor tgs reverse parking sensor control unit TGS5042-A00 AD708 equivalent
Text: : * Battery operable * High repeatability/selectivity to CO * Linear relationship between CO gas , Y-axis shows theoutput current of the sensor (Iout/µA) in each gas . Output current is linear to CO , , EN50291, and RoHS requirements * Residential and commercial CO detectors * CO monitors for industrial applications * Ventilation control for indoor parking garages * Recreational vehicle CO detectors * Marine CO detectors * Fire detection Figaro's TGS5042 is a battery operable electrochemical sensor which
|
Original
|
PDF
|
UL2034,
EN50291,
TGS5042
TGS 800 gas sensor
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
TGS 800 figaro
electrochemical sensor CO
carbon monoxide sensor electrochemical
sensor tgs
reverse parking sensor control unit
TGS5042-A00
AD708 equivalent
|
2006 - usb-co
Abstract: Carbon Monoxide carbon monoxide sensor
Text: , designed to record Carbon Monoxide ( CO ) gas levels for later analysis. It is not an alarm/safety/warning , EL-USB-CO Carbon Monoxide ( CO ) Data Logger with USB Interface This data logger measures and stores up to 32,510 Carbon Monoxide ( CO ) readings over a 0 to 1000 ppm measurement range and 10 to +40°C , ppm CO measurement range · Stores up to 32,510 Measurements · User-Programmable Warning Threshold , emitted by the EL-USB-CO to indicate a high level of CO do not provide adequate warning to those in the
|
Original
|
PDF
|
April/2006
usb-co
Carbon Monoxide
carbon monoxide sensor
|
2011 - H723
Abstract: NORGREN -HERION HERION GBXE022AIAD03 festo phoenix "high voltage resistor" burkert solenoid asco parker valves norgren Valves
Text: :// Gas group Max. external inductivity Lo Max. external capacity Co Gas group Max. external inductivity Lo Max. external capacity Co Safety-related maximum voltage
|
Original
|
PDF
|
MCR-EX-SL-SD-21-60-LP
IF-2011)
MCR-EX-SL-SD-21-60-LP
H723
NORGREN -HERION
HERION
GBXE022AIAD03
festo
phoenix "high voltage resistor"
burkert solenoid
asco
parker valves
norgren Valves
|
Not Available
Abstract: No abstract text available
Text: professional measuring instrument, designed to record Carbon Monoxide ( CO ) gas levels for later analysis. It , EL-USB-CO Carbon Monoxide ( CO ) Data Logger with USB Interface This data logger measures and stores up to 32,510 Carbon Monoxide ( CO ) readings over a 0 to 1000 ppm measurement range and 10 to +40°C , 1000 ppm CO measurement range Stores up to 32,510 Measurements User-Programmable Warning , reasons: 1. The lights and sound emitted by the EL-USB-CO to indicate a high level of CO do not provide
|
Original
|
PDF
|
April/2006
|
Not Available
Abstract: No abstract text available
Text: professional measuring instrument, designed to record Carbon Monoxide ( CO ) gas levels for later analysis. It , EL-USB-CO Carbon Monoxide ( CO ) Data Logger with USB Interface This data logger measures and stores up to 32,510 Carbon Monoxide ( CO ) readings over a 0 to 1000 ppm measurement range and 10 to +40°C , 1000 ppm CO measurement range Stores up to 32,510 Measurements User-Programmable Warning , reasons: 1. The lights and sound emitted by the EL-USB-CO to indicate a high level of CO do not provide
|
Original
|
PDF
|
April/2006
|
"Co Sensor"
Abstract: NDIR CO sensor PHZH2002 block diagram of suction pump RECORDER fuji microjet phc PEX00DL1-5000B CO Gas sensor ndir PHZH1002 NDIR gas sensor Non-Dispersive InfraRed NDIR absorption sensor
Text: CO /O2 GAS ANALYZER FOR STACK GAS DATA SHEET ZSW This instrument is equipped with a non-dispersive infrared CO sensor and a galvanic oxygen sensor and used for measuring CO and O2 in the gas , calculation · Conversion of measured CO gas concentration into a value at standard O2 concentration , gas (14th code) Not provided CO /N2 (3.4L, cylinders 1) 1 4 Gas extractor, Flange dimension , solenoid gas cooler valve 2-direction solenoid valve Solenoid pump Infrared CO sensor Galvanic
|
Original
|
PDF
|
|
list of sensors used in automobiles
Abstract: MGS1100 carbon monoxide ir sensor "Co Sensor" Microsens CO Gas sensor ir CO Gas sensor smoke sensor schematic CO Sensor carbon monoxide sensor
Text: Monoxide Gas Sensor The Motorola MGS1100 carbon monoxide ( CO ) sensor features a gas sensitive, thin film , ¢ Industrial Stationary and Portable CO Detectors and Probes ⢠Gas /Fuel Appliance CO Monitoring Common Sources of CO in the Home ⢠Gas Appliances (Stoves, Dryers, Waterheaters) ⢠Fuel Fired Furnaces â , presence of gas S = Rs(air)/Rs( gas ) (4) Sensitivity measurements are taken at CO concentrations of 0,15 , effective method for the detection of CO gas while minimizing the influence of humidity uses a sequence of
|
OCR Scan
|
PDF
|
MGS1100/D
MGS1100
b3b7255
list of sensors used in automobiles
carbon monoxide ir sensor
"Co Sensor"
Microsens
CO Gas sensor ir
CO Gas sensor
smoke sensor schematic
CO Sensor
carbon monoxide sensor
|
list of sensors used in automobiles
Abstract: co sensor Air Sensor MGS1100 CO Gas sensor
Text: Monoxide Gas Sensor The Motorola MGS1100 carbon monoxide ( CO ) sensor features a gas sensitive, thin film , ) Recreational Vehicle CO Detectors Industrial Stationary and Portable CO Detectors and Probes Gas /Fuel Appliance , of CO in the Home · · · · · Gas Appliances (Stoves, Dryers, Waterheaters) Fuel Fired Furnaces , the film to enhance its sensitivity to CO . This structure is supported by a micromachined silicon , sensing layer ( ± Vg). Features · · · · · · · Sensitivity Range: 15 to over 1000 ppm CO Low Humidity
|
OCR Scan
|
PDF
|
MGS1100/D
MGS1100
1100/D
list of sensors used in automobiles
co sensor
Air Sensor
CO Gas sensor
|
list of sensors used in automobiles
Abstract: co sensor "Co Sensor" GS1100 MGS1100
Text: Data Sheet MGS1100 Carbon Monoxide Gas Sensor The Motorola MGS1100 carbon monoxide ( CO ) sensor , Stationary and Portable CO Detectors and Probes Gas /Fuel Appliance CO Monitoring 1 2 3 4 PIN N U M B E R Heater Ground Sensor Pin Heater Power Sensor Pin m Common Sources of CO in the Home · · · · · Gas , < /> "v > & 2.0 1.5 60 ppm CO 400 ppm CO 0 20 40 r 80 100 1.0 0.5 0 Rs( gas )/Rs (60 ppm CO ) VERSUS CO CONCENTRATION Rs( gas )/Rs (60 ppm CO , 50% RH) VERSUS RELATIVE HUMIDITY Figure 2
|
OCR Scan
|
PDF
|
MGS1100/D
MGS1100
MGS1100
2PHX43329-0
list of sensors used in automobiles
co sensor
"Co Sensor"
GS1100
|
Not Available
Abstract: No abstract text available
Text: MOTOROLA SEMICONDUCTOR TECHNICAL DATA MGS1100 MGS1100 Carbon Monoxide Gas Sensor The Motorola MGS1100 carbon m onoxide ( CO ) sensor features a gas sensitive, thin film m e tal-oxid e layer , ⢠Industrial Stationary and Portable C O Detectors and Probes ⢠Gas /Fuel Appliance CO , OPERATION An effective m ethod for the detection of CO gas while m ini m izing the influence of hum , film to enhance its sensitivity to CO . This structure is supported by a microm achined silicon
|
OCR Scan
|
PDF
|
MGS1100
MGS1100
90CNOM.
|