INVENSYS SENS Search Results
INVENSYS SENS Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| 73725-0010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 73725-1010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 72313-4010BPLF | Amphenol Communications Solutions | USB 2.0, Input Output Connector, Single Deck Receptacle, Type A, Through Hole, Right Angle, 4 Positions with Sensor Contact |
Documents mentioning INVENSYS SENS
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| IAMBDAA An Invensys company With the PD Series, | IAMBDAA An Invensys company With the PD Series, LAMBDA is presenting a revolutionary new concept of AC/DC converters. Through its extreme compactness, an efficiency of 90% and the mechanical construction, these modules offer the maximum in design flexibility. |
OCR Scan | ||||
| mml400 | OMEGA IñHBDa/k An Invensys company INPUT Input protection internal fuse Thermal protection standard Switching frequency lOOKHz Input with PFC : (MML400PF0, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML40QPFC MML600 MML800 Power factor |
OCR Scan | ||||
| IAMBOAA An Invensys company Input voltage range | IAMBOAA An Invensys company Input voltage range 110-220VAC or wide ränge 85-265VAC dependent series DC Input Check with Technical Sales Input protection Internal Fuse OUTPUT Power (convection cooled) 15 to 150W Adjustment voltage unique on series DIN P Line regulation |
OCR Scan | ||||
| invensys | IAMBDAA An Invensys company WATTS POWER SUPPLY AC/DC SINGLE OR DUAL OUTPUT Front panel voltage selection Low noise and ripple Low leakage current DC 'on’ LED indicator EDITION 2001 Guarantee 5 years Input voltage range 85-115V / 98-132V 170-230V / 195-265VAC |
OCR Scan | ||||
| invensys | UMBDAA An Invensys company Input voltage range: 230VAC RMS single phase (150-275VAC RMS) Input frequency: 45-66HZ Input current: Sinusoidal to meet harmonic limitations of BS EN61000-3-2 (1EC 555-2) Power factor: >0.95 (50-100% load) OUTPUT Output voltage: |
OCR Scan | ||||
| mml400pfc | OMEGA LJUHBDMA An Invensys company INPUT Input protection internal fuse Thermal protection Switching frequency standard lOOKHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range Inrush current (peak) 85*'264VAC Power factor Start up time (max.) |
OCR Scan | ||||
| sidac | Data Book by TECCOR ELECTRONICS 1800 Hurd Drive Irving, Texas 75038 United States of America Phone: (972) 580-7777 Fax: (972) 550-1309 Web site: http://www.teccor.com E-mail: sidactor@teccor.com An Invensys company Teccor Electronics is the proprietor of the trademarks SIDACtor®, Battrax™, and TeleLink™. |
Original | ||||
| alpha 400 | IAMBDAA An Invensys com pany Input voltage range: ALPHA 400/600: 85-264 VAC ALPHA 1000 - 1000W 90 - 264VAC @ 45°C Frequency: 47 to 63Hz In-rush current: < 50 A Input frequency: -PFC -Forward convertor ALPHA 400/600/1000 100 KHz 200 KHz 100 KHz 200 KHz 200 KHz 200 KHz |
OCR Scan | ||||
| 150p | IÂUBDAA An Invensys company Input voltage range 85-132/170-265VAC auto select (EWS 100P and 150P) 85-265VAC wide range (EWS 300P and 600P) Frequency 47-63HZ Inrush current 28A on EWS 100P and 150P 30A on EWS 300P 40A on EWS 600P Input protection fuse DC Input |
OCR Scan | ||||
| LAMBDAA An Invensys company Input voltage | LAMBDAA An Invensys company Input voltage 100-120-220-230-240 VAC range ± 10% Voltage selection on input transformer Frequency 47 to 63Hz OUTPUT Power (natural convection) 15 at 100W Adjustment voltage range + 5% minimum Line regulation ± 0.15% Load regulation |
OCR Scan | ||||
| Data Book and Design Guide TECCOR ELECTRONICS | Data Book and Design Guide TECCOR ELECTRONICS 1800 Hurd Drive Irving, Texas 75038 United States of America Phone: +1 972-580-7777 Fax: +1 972-550-1309 Web site: http://www.teccor.com E-mail: sidactor.techsales@teccor.com An Invensys company Teccor Electronics is the proprietor of the SIDACtor®, Battrax®, and TeleLink® |
Original | ||||
| LN/LD Series Home Page 1 of 3 | Product Index | LN/LD Series Home Page 1 of 3 | Product Index AC/DC DC/DC EMI Filters Lab Racks Value Added Older Models Tech. Downloads What's New Press Releases Trade Shows Facility Locations Contact Us N/A Sales Reps N/A Distributors Lambda Home Invensys Lambda UK Lambda EMI |
Original | ||||
| U M B D M & An Invensys company Input voltage | U M B D M & An Invensys company Input voltage range Input frequency HSU 45/60/100 115/230VAC selectable 47-440Hz OUTPUT Power 45 to 100W Number of outputs 1 and 2 auxilliary Line regulation ±0.4% Load regulation of (50 to 100% load charge) 1% on principal output |
OCR Scan | ||||
| lzs-500 | ^gm m invensys A LAMBDAA — « » « °- _ _ _ _ INSTRUCTION MANUAL LZS/SE-500 SERIES POWER SUPPLY 3055 Del Sol Blvd San Diego, Ca. 92154 Phone (619) 575-4400 Fax (619) 575-7185 P/N: IMLZSSE500 Rev. B DATE: July 2002 usSiamin stru ctio n m anual ALL INFORMATION CONTAINED IN THIS MANUAL APPLIES TO BOTH THE LZS-500 AND SE-500 |
OCR Scan | ||||
|
|
||||||
| PAH/PAHD Iß M B D ß A A n Invensys co m p a n y | PAH/PAHD Iß M B D ß A A n Invensys co m p a n y INPUT Input voltage range: 36-76VDC Input surge voltage: 90VDC for 1 second SINGLE OUTPUT Output power: 50 to 200W Adjustable output: models 2.5 and 3.3V: ±10% model 5V: -40 +15%; other models: -40 +10% Line regulation: |
OCR Scan | ||||
| zero speed | Hall Effect Zero Speed Sensor APPLICATIONS Industrial process control Factory automation Meter Pump Roller Mixer Fan speed Transmission Gear reducer RPM Process speed Synchronization Spindle Generator set Compressor speed Dyno testing R&D testing RPM FEATURES |
Original | ||||
| clarostat | Precision Potentiometer/ Position Sensor FEATURES Conductive Plastic Element Smooth Feel 5MM Shaft Revolutions Quiet Electrical Output Robust Construction Center Tap Optional Terminal Configurations The ALL NEW Series 578 conductive plastic precision potentiometer puts CLAROSTAT |
Original | ||||
| Hall Effect Rotary Position Sensor APPLICATIONS | Hall Effect Rotary Position Sensor APPLICATIONS MARINE Throttle position Outboard motor position Inboard lever control Control position: Rudder position Trim tab and plane position Drive tilt and drive gimbal position Auto pilot feedback Drive by wire systems |
Original | ||||
| SensorCube™ FEATURES Environmentally Sealed (Both | SensorCube™ FEATURES Environmentally Sealed (Both Shaft and Terminals) Long Life Cycling Rugged-robust Design Focusing on Industrial Applications Low cost High Accuracy Excellent Repeatability High Operational Speed Available in a Variety of Angle Measuring |
Original | ||||
| 5/8 M16* METERS / SECOND 2.5 5.1 7.6 10.1 12.7 | 5/8 M16* METERS / SECOND 2.5 5.1 7.6 10.1 12.7 15.2 17.8 20.3 22.9 3042 SERIES INTRINSICALLY SAFE VRS SENSORS 25.4 40 30 20 V P/P 10 100 200 300 400 500 600 700 800 900 1000 INCHES / SECOND NRTL/C FOR HAZARDOUS LOCATIONS OPTIMUM ACTUATOR: 12 DP (Module 2.11) Ferrous Metal Gear |
Original | ||||
| 3/8 METERS / SECOND M12* 3015 SERIES GENERAL | 3/8 METERS / SECOND M12* 3015 SERIES GENERAL PURPOSE VRS SENSORS 2.5 5.1 7.6 10.1 12.7 15.2 17.8 20.3 22.9 25.4 60.0 52.5 45.0 37.5 30.0 V P/P 22.5 15.0 7.5 100 200 300 400 500 600 700 800 900 1000 INCHES / SECOND FOR GENERAL SPEED SENSING APPLICATIONS WHERE SENSOR SIZE IS OF CONCERN. PERFORMS BEST AT |
Original | ||||
| rtv 730 | 1 to 300 psig Pressure Sensors in a Button Package APPLICATIONS Medical Equipment Computer Peripherals Pneumatic Controls HVAC FEATURES Button Package High Pressure Small Size Low Noise RTV 730 Die Attach EQUIVALENT CIRCUITS Vs The SX7 Series sensors offer a high pressure sensor |
Original | ||||
| sensym ict | Battery-Powered Digital Pressure Gauges APPLICATIONS Process Control Test and Measurement FEATURES ±0.25% Test Gauge Accuracy 316 Stainless Steel Sensor Long Battery Life Rugged Design 0-15 psig to 0-1000 psig, and -30 in Hg to 100 psi The SenSym ICT Digital Pressure Gauge Series |
Original | ||||
| METERS / SECOND 2.5 5.1 7.6 10.1 12.7 15.2 17.8 | METERS / SECOND 2.5 5.1 7.6 10.1 12.7 15.2 17.8 20.3 22.9 25.4 16 14 12 10 V P/P 8 6 4 2 100 200 300 400 500 600 700 800 900 1000 1/4 M8* 3050 SERIES MINIATURE VRS SENSORS INCHES / SECOND FOR SPEED SENSING APPLICATIONS WHERE SENSOR MOUNTING AREA IS VERY LIMITED. |
Original | ||||
| ma215ht | 3/8 1/2 M12* MA215HT MA315HT SEALED FRONT-END HI-TEMP VRS SENSORS METERS / SECOND 2.5 5.1 7.6 10.1 12.7 15.2 17.8 20.3 22.9 25.4 60.0 52.5 45.0 37.5 V P/P 30.0 22.5 15.0 7.5 100 200 300 400 500 600 700 800 900 1000 INCHES / SECOND FOR HIGH TEMPERATURE SPEED SENSING APPLICATIONS IN WHICH THE SENSOR TIP IS EXPOSED TO |
Original | ||||