EF20 TRANSFORM Search Results
Documents mentioning EF20 TRANSFORM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| High Frequency Wire Wound Transformers EF20 | High Frequency Wire Wound Transformers EF20 Platforms - THT Type AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available Electrical Specifications @ 25°C - Operating Temperature -40°C to 130°C¹ |
Original | ||||
| transformer ef20 | Inductive Components Product Family Name Material Data Sheet PTH Transformer EF20 B78311xxx Date 08.05.2007 Version 03 Construction Element Material group Materials CAS if applicable mass [weight-%] min typical Active Part max Sum [%] Traces 53.00 Ceramic |
Original | ||||
| ef20 | CCFL Driving Inverter Transformer INT015T TYPE(EF20) Mechanical Dimension:Unit:mm Characteristic(reference) PART NO. INT015T-1 INPUTVOLTAGE (Vdc) SUITABLE FREQUECY MAX.LAMP WATTE (KHZ) (W) 15.0 30-80 9.0 MAX.OPEN VOLTAGE EFFICIENCY (Vrms) (%) 1500 70-80 INT016T TYPE(EPC17) |
Original | ||||
| High Frequency Wire Wound Transformers EF20 | High Frequency Wire Wound Transformers EF20 Platforms - THT Type AC/DC and DC/DC Switching Transformers Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available Electrical Specifications @ 25°C - Operating Temperature -40°C to 130°C¹ |
Original | ||||
| aef20-3648 | RoHS AEF20-3648 Flyback Transformer EF20 Ferrite Core Design 10 Pin Through Hole Flyback Topology Electrical Specifications @ 25°C INDUCTANCE LEAKAGE INDUCTANCE POLARITY @10KHz / 0.23V HP-4284A 100KHz / 0.23V HP-4284A 10KHz / 1.0V 3-1: 1.0 mH ±10% @ 0ADC |
Original | ||||
| hi-pot | High Frequency Wire Wound Transformers EF20 Platforms - THT Type AC/DC and DC/DC Switching Transformers Electronics Reinforced Insulation 3000Vrms Hi-pot Topology: Flyback Custom Design Available Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C 1 |
Original | ||||
| ef20 | FLYBACK TRANSFORMER SIZE EF20 • 2 or 3 OUTPUTS : 5/5v or 12/12v or 3.3+5/12v • Primary / Secondary Insulation ≥ 4000V • Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 8mm Ambient temperature < 50°C |
Original | ||||
| inverter transformer | CCFL Driving Inverter Transformer INT015T Type (EF20) Mechanical Dimension: Unit: mm 15.0 0.3 15.8 Max. 22.0 Max. 3.0 3 1 Schematic : 6 2 22.0 Max. 15.0 0.3 PRI 7 4 3 SEC 8 1.5 0.3 8 0.6 13.5 0.3 5 1 7 6 15.0 0.3 Characteristic (reference) PART NO. INT015T-1 |
Original | ||||
| ISDN Transformers B78311-P1451-A5 UK0 Interface | ISDN Transformers B78311-P1451-A5 UK0 Interface B78311-P1450-A5 Application 16 max ■ Use in NT and local central office ■ Matched to the following ICs, e.g. 3,4±0,4 B78311-P1451: PEB/PSB 8091 and 8191; B78311-P1451: AM 2091 B78311-P1450: PEB/PSB 8090; AM 20902 |
Original | ||||
| b78311 | ISDN Transformers B78311-P1451-A5 UK0 Interface B78311-P1450-A5 Application 16 max ■ Use in NT and local central office ■ Matched to the following ICs, e.g. 3,4±0,4 B78311-P1451: PEB/PSB 8091 and 8191; B78311-P1451: AM 2091 B78311-P1450: PEB/PSB 8090; AM 20902 |
Original | ||||
| kaschke | Industrial electronics Consumer electronics Safety insulation transformers for SmartPower controller family Communication and entertainment electronics Lighting technology Automotive electronics KASCHKE KG GMBH & CO. PO box 2542 · 37015 Göttingen · Germany |
Original | ||||
| flyback transformer construction | ® TOPSwitch Flyback Transformer Construction Guide ® Application Note AN-18 Introduction Ferrite Core Manufacturer’s Catalogs This application note is a design and construction guide for margin wound or triple insulated wire wound flyback transformers suitable for use with TOPSwitch. Margin wound |
Original | ||||
| ccfl driving inverter transformer | CCFL Driving Inverter Transformer INT003T TYPE(EFD25) Mechanical Dimension:Unit:mm Characteristic(reference) PART NO. INT003T-1 INPUTVOLTAGE (Vdc) SUITABLE FREQUECY MAX.LAMP WATTE (KHZ) (W) 15.0 30-80 17.0 MAX.OPEN VOLTAGE EFFICIENCY (Vrms) (%) 1500 70-80 |
Original | ||||
| ccfl driving inverter transformer | CCFL Driving Inverter Transformer INT003T Type (EFD25) Mechanical Dimension: Unit: mm 6.0 0.3 15.0 Max. 27.5 Max. 7.3 0.3 7.3 0.3 Schematic : 10 6 3 5 26.0 Max. 9 12 2 3.8 Max. 1 14.0 0.3 4 8 3 7 PRI 5 8 9 7 11 0.5 1 10 4 SEC 12 6 3.8 0.3 Characteristic (reference) |
Original | ||||
|
|
||||||
| Electronic Transformer Product Identification T P | Electronic Transformer Product Identification T P ① ② Note: H WEE13 ■■■■ V □□□ ③ ④ ⑤ ⑥ ⑦ F ⑧ ① Transformer; ② Pin type. P: DIP ; S: SMD; ③ Classification. H: for High frequency; L: for Low frequency; P: Plane Structure; |
Original | ||||
| Direct Link 0921 Applications & Cases Inductors | Direct Link 0921 Applications & Cases Inductors July 2004 Packed with power AC/DC and DC/DC converters for high-power and high-current applications are enjoying high growth rates throughout the electronics industry. Today, these devices are designed exclusively as switchmode power supplies (SMPS) for |
Original | ||||
| di-123 | DI-123 Design Idea TinySwitch-III ® 9.65 W, Dual Output Power Supply for Residential Heating Control Application Device Power Output Input Voltage Output Voltage Topology Residential Heating Control TNY275PN 9.65 W 185 - 265 VAC 5 V / 0.25 A, 24 V / 0.35 A |
Original | ||||
| eer22 | CCFL Driving Inverter Transformer Type INT001T (EER22) Dimensions: UNIT : mm 22.0 Recommand Pad 6 1.1 3.75 25.0 1 6 7 11 INPUT VOLTAGE : 17(Vdc) SUITABLE FREQUENCY : 30~80(kHz) MAX.LAMP WATTANG :20W MAX.OPEN VOLTAGE :2150(Vrms) EFFICIENCY :75~80% 7 0.8 25.0 |
Original | ||||
| di-123 | Design Idea DI-123 ® TinySwitch-III 9.65 W, Dual Output Power Supply for Residential Heating Control Application Device Power Output Input Voltage Residential Heating Control TNY275P 9.65 W 185-265 VAC Design Highlights • The flyback converter shown in Figure 1 uses a TNY275 |
Original | ||||
| epc19 | CCFL Driving Inverter Transformer INT013T (EPC19) Dimensions: UNIT : mm Recommand Pad 6 21.0 0.6 7 1 INPUT VOLTAGE :12(Vdc) SUITABLE FREQUENCY : 30~80(kHz) MAX.LAMP WATTANG :10W MAX.OPEN VOLTAGE :1700(Vrms) EFFICIENCY :80% 6 17.0 8 1 Specifications 0.9 2.5 |
Original | ||||
| top243y | Design Example Report Title 19.3 W Wide Range Flyback Power Supply using TOP243Y Specification Input: 207 – 400 VAC Outputs: +14 V / 1.2 A; +5 V / 0.5 A Application Oven Control Author Power Integrations Applications Department Document Number DER-105 Date |
Original | ||||
| Electrical / Environmental ISDN Isolation | Electrical / Environmental ISDN Isolation Transformers • Insulation Resistance, 100 Mohms minimum • Isolation voltage levels available for domestic and international safety standard • Standard Operating Temperature Range 0°C to +85°C Specifications |
Original | ||||
| di-122 | Design Idea DI-122 ® TinySwitch-III 13 W (17.2 W Peak) Non-Isolated Power Supply for White Goods: <150 mW No-load Power Consumption Application Device Power Output White Goods TNY279P 13 W / 17.2 W Pk Input Voltage Output Voltage Topology 85-265 VAC -5 V, 2.0 A / -12 V, 0.25 A / 0.6 A Pk |
Original | ||||
| di-177 | DI-177 Design Idea TinySwitch-III ® 9 W, High Ambient Temperature Supply for Oven Control Application Device Power Output Input Voltage Output Voltage Topology Oven Control TNY279PN 9W 165 – 265 VAC 9V Flyback Design Highlights • High ambient temperature operation (TAMB = 105 °C) |
Original | ||||