    flyback transformer
    FLYBACK TRANSFORMER • SIZE ETD44 • 4 OUTPUTS : 5+12 / 5+12v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 8mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    iec950
    FLYBACK TRANSFORMER • SIZE E16 • 3 OUTPUTS : 5 / 15 / 24v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    iec950
    FLYBACK TRANSFORMER SIZE E16 • 2 OUTPUTS : 2 x 24v • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    iec950
    TRANSFORMER FOR TINYSWITCH SIZE E16 • SINGLE OUTPUT : 5 or 12v • Primary / Secondary Insulation ≥ 4000V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 70°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    el19
    FLYBACK TRANSFORMER • SIZE EL19 • 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 60°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    flyback transformer
    FLYBACK TRANSFORMER SIZE E25 • 3 or 1 OUTPUTS : 5+12/12v or 24v • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    iec335
    44 E16 • 2 Outputs: 5 & 12V, Single Output: 5 or 12V Size • Primary / Secondary Insulation > 4000V • Primary / Auxiliary Insulation > 1500V • Creepage distance Primary / Secondary > 6mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    iec335
    Size E16 • Single Output: 5 or 12V 44 • Primary / Secondary Insulation > 4000V • Creepage distance Primary / Secondary > 6mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation • Exclusively uses UL94-V0 listed materials
    Original PDF
    iec950
    TRANSFORMER FOR TINYSWITCH • SIZE E16 • SINGLE OUTPUT : 5 or 12v Primary / Secondary Insulation ≥ 4000V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 85°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    ef20
    Size EF20 • 2 or 3 Outputs: 5/5v or 12/12v or 3.3+5/12V 44 • Primary / Secondary Insulation > 4000V • Primary / Auxiliary Insulation > 1500 V • Creepage distance Primary / Secondary > 8 mm / > 6 mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    erl28
    FLYBACK TRANSFORMER SIZE ERL28 • 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation
    Original PDF
    A Dimensions: [mm] B Recommended land pattern:
    A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Inductance 100 kHz/ 100 mV Turns ratio C Schematic: Value Unit Tol. µH ±10% L 1500 n 160 : 7 : 7 : 18 0.8 A typ. ±3% Saturation current |ΔL/L| < 20%
    Original PDF
    TRD Series three-phase transformer controllers
    TRD Series three-phase transformer controllers General remarks: The TRD series of transformer controllers for three phase AC fans and motors provide energy saving speed control without the creation of additional motor noise which you get with most electronic controllers. Vacuum impregnation also reduces
    Original PDF
    4000vac
    2 PRI 120-375V 66kHz 3 4 Cancel NC 1 8 SEC 8V - 300mA 7 AUX 5 ELECTRICAL SPECIFICATIONS @ 25°C unless otherwise noted: D.C. RESISTANCE (@20°C): 1-5 , 0.035 Ohms ±20%. 2-3 , 2.15 Ohms ±10%. 7-8 , 0.028 Ohms ±20%. DIELECTRIC RATING: 4000VAC, 1 minute tested by applying 5000VAC for 1 second between pins 1-8.
    Original PDF
    Toroidal Transformer Data Sheet 30-Dec-2009 Open
    Toroidal Transformer Data Sheet 30-Dec-2009 Open Style, with leads, 2x115V Primary, 120VA 115V 0V 115V 0V Brown Red Vsec Blue Black 0V Green Yellow Vsec Violet Orange 0V RS Code No. RS Part No. Primary 2x115V @ 50/60Hz Secondary 2 x Vsec, @ 60VA Each Suitable for Series/Parallel Connection
    Original PDF
    Toroidal Transformer Data Sheet 20-Aug-2009 Open
    Toroidal Transformer Data Sheet 20-Aug-2009 Open Style,LVL,with leads, 230V Primary,105VA 230V Brown Red Vsec Primary 230V @ 50/60Hz Secondary Vsec, @105VA 120°C Red 0V Blue RS Code No. 0V RS Part No. 671-9198 81605-P1S1 Full Load Vsec [V] Rated Current per Sec [A]
    Original PDF
    toroidal transformer
    Toroidal Transformer Data Sheet 30-Dec-2009 Open Style, with leads, 2x115V Primary, 80VA 115V 0V 115V 0V Brown Red Vsec Blue Black 0V Green Yellow Vsec Violet Orange 0V RS Code No. RS Part No. Primary 2x115V @ 50/60Hz Secondary 2 x Vsec, @ 40VA Each Suitable for Series/Parallel Connection
    Original PDF
    CUSTOMER TERMINAL RoHS L E A D (P b )-F R E E S n
    CUSTOMER TERMINAL RoHS L E A D (P b )-F R E E S n 96% , Ag4% Yes Yes PA R T M U S T S U RFACE A 0 .0 2 5 IN S E R T F U L LY TO IN R E C O M M E N D E D more than you expect A LTE R N A T E GRID DOT S Q .(9 ) M A R K IN G LO C ATES D E T A IL TER M . T E ST
    OCR Scan PDF
    C U S TO M E R TE R M IN A L S n96% , Ag4% R oHS
    C U S TO M E R TE R M IN A L S n96% , Ag4% R oHS L E A D ( P b )-F R E E Y es Yes IVidcam PART MUST INSERT FULLY TO SURFACE A IN RECOMMENDED GRID 0 .0 2 4 ( 9 ) | _ A_ [■60] ELECTRICAL SPECIFICATIONS DOT LOCATES TERM. #1 . 0 9 0 / . 11 5 [2 .2 9 /2 .9 2 ]
    OCR Scan PDF