Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CHILLED WATE Search Results

    Documents mentioning CHILLED WATE

    Document Partial File Text Tags Type PDF
    pressure transmitter
    AB-6040 Specifications/Instructions Pressure Transmitter PY7100A General PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water, brine, lubricating oil, steam, air, and other fluids, and converts measured values into 4
    Original PDF
    qxa2000
    1 QXA2000 1542P02 1542P01 542 AQX2000 Condensation Monitor QXA2000 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant. It operates on AC / DC 24 V and has a potentialfree AC / DC 1…48 V changeover
    Original PDF
    Refrigerant Distribution Unit (RDU) and Piping
    Refrigerant Distribution Unit (RDU) and Piping SKU ACDA901 Technical Data American Power Conversion Legal Disclaimer The information presented in this manual is not warranted by the American Power Conversion Corporation to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed
    Original PDF
    s Room thermostats with KNX communications 3 191
    s Room thermostats with KNX communications 3 191 RDG100KN RDG160KN – For fan coil unit applications – For universal applications – For use with compressor in DX type equipment • KNX bus communication (S-mode and LTE mode)
    Original PDF
    qxa2603
    3 SIEMENS QXA2601/QXA2603 QXA2602/QXA2604 Condensation Monitor • CB1N3302en_01 2014-04-24 302 QXA2601 QXA2602 QXA2603 QXA2604 Operating voltage AC / DC 24 V or AC 230 V Potential free changeover contact AC/ DC 1…30 V or AC 230 V Simple and fast mounting
    Original PDF
    System Catalog 2014 The information in this
    System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.
    Original PDF
    ss2-mcm100-0100
    No. SS2-MCM100-0100 Electromagnetic calorimeter Model MCM10A OVERVIEW The Yamatake model MCM10A is a custody transfer meter used to measure the calorie consumption of air conditioning systems in buildings or shopping malls or it can be used in district heating/cooling applications.
    Original PDF
    SBC-VAV SBC-VAV™ Variable Air Volume Controller
    SBC-VAV SBC-VAV™ Variable Air Volume Controller The SBC-VAV family of terminal box digital controllers is designed to function in numerous scenarios that require variable air volume (VAV), constant air volume (CAV), and CO2 measurement, while providing flexible mounting solutions to increase ease of installation. Each controller works on
    Original PDF
    SPF546 Soft-pack Cell Packaging Machine
    SPF546 Soft-pack Cell Packaging Machine Half-shell cold-forming < 3° all around R=1mmall around 6° max. 5 R=1mmall around MAIN FUNCTIONS GENERAL INFORMATION The Soft-pack Cell Packaging machine SPF546 has been designed to pack electrochemical cells in a multilayer film
    Original PDF
    v4073a
    I N S TA L L AT I O N INSTRUCTIONS V4073A Motorised Mid-Position Valve Application The V4073A valve has been designed to control the flow of water in a small bore domestic central heating system where both radiator and hot water cylinder circulation are pumped.
    Original PDF
    qbe61
    1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0…10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.
    Original PDF
    qbe61
    1 Pressure Detectors 901 QBE61.1… Active pressure detector delivering a DC 0…10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning
    Original PDF
    REFERENCE AND APPLICATION DATA Humidity Sensors
    REFERENCE AND APPLICATION DATA Humidity Sensors HIH Series PSYCHROMETRICS & MOISTURE MOISTURE measurements involve different terms and units. Moisture terms and units all fall under the area of psychrometrics, the study of water vapor concentration in air as a
    Original PDF