    Al lili Mil» asea b r o w n bo veri ABB Relays
    Al lili Mil» asea b r o w n bo veri ABB Relays --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
    OCR Scan PDF
    asea
    I l I I I I M il» ASEA BROWN BOVERI ABB R e la y s Selection guide B03-0270E Line and cable protection Data subject to change without notice ) Addition for Une protection with phase selection ' I Fault locator RANZA B03-7110E I | I_________ 1 ASEA Selection guide
    OCR Scan PDF
    ASEA INFORMATION Unbalance Protection Type RYBIA
    ASEA INFORMATION Unbalance Protection Type RYBIA RK 60-337 E Reg. 7456 for Series capacitors ■ DESCRIPTION 07 RELAY PROTECTION ASEA capacitor units consist of a number of parallel connected GENERAL elements each of them in series with a built-in fuse. If a short
    OCR Scan PDF
    i ASEA Catalogue RK 93 E Edition 1 May 1966 File
    i ASEA Catalogue RK 93 E Edition 1 May 1966 File R Part 2 Frames and connectors for relays Contents: Front terminals Extension bolts and terminal screws Flush mounting frames Blanking plates Adapting frames Relay testing block RTNP P -2 3 4 9 9 10 ASEA Front terminals
    OCR Scan PDF
    brown boveri
    A I pip ASEA BROWN BOVERI add d , ABB Relays Abstract Reference -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------— Type
    OCR Scan PDF
    C a t a lo g u e RK 13-5 E Indlcators type RSP
    C a t a lo g u e RK 13-5 E Indlcators type RSP and RRSP T-ypn RRSP Jn p lu g -J n tfB B i-g n March 1970 E d lilo n t f7236<k ASEA ASEA Contents Qaneral Design and mode of operation Versions and mounting Maintenance Technical data and Cat. Nos. Ordering particulars
    OCR Scan PDF
    racic
    A S p Sp _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ASEA BROWN BOVERI « ,« , ________________________________________________________________________________________________________________ _ Type RACIC B03-7210 Feeder protection January 1985 Changed since May 1983
    OCR Scan PDF
    rarib
    II m II M V II ASEA BROWN BOVERI ABBRe,ays i_____________________________________________________________________________________________________________________________________________________________ Type RARIB B03-4015E Negative phase-sequence, w „■
    OCR Scan PDF
    rhgx
    Mil Ili» III ASEA B R O W N BO VERI A BB Relays Maximum permiss­ ible ambient temperature for relays Permissible power I n c e o e of n f relaying r o la w in n losses equipment in cases type RHGX and cubicles type VSG and VSH ASEA relays are designed for a maximum am­
    OCR Scan PDF
    asea
    Ak 1111 ASEA BROWN BOVERI a b b Relays ------------------------------------------------------------------------------ _ Neutral point voltage selection assembly * ' _ _ ■ ---------------- B03-8510E Data subject to change without notice • New Application
    OCR Scan PDF
    preset potentiometer
    Ah Bi It ASEA B R O W N BO VERI ABB Relays ________________________________________________________________________________ _________ ___ Type RXTMB 1 _… _________________________________________________ B03-9172 .. pagei June 30. 1982 Preset potentiometer unit
    OCR Scan PDF
    asea
    ASEA C a t a lo g u e O cto b er 1966 Indicators typ e RSC and RRSC The in d ic a to rs are chiefly used in relay p ro te ctio n s to Show Whether the protec­ tio n o r some p a n of it has operated. M a ry ASEA relays are fitted with in d ica tin g flags
    OCR Scan PDF
    asea
    ik II11 — ________________________________________________________________________________ ASEA BROWN BOVERI ABBRe,ays Type RXBA 4 £03-8310E Fuse failure relay# Abstract Application Changed since May 1983 Data subject to change without notic • Detects single-, two- or three-phase fuse
    OCR Scan PDF
    rxig 21
    ABB ASEA B R O W N BO V E RI A66 Relavs Abstract Application -------------------------------------------------------------------- — ---------------------------------------- — IT Type RXIG 21 B03-2032Ey I Instantaneous ac over- and undercurrent relays
    OCR Scan PDF
    brown boveri
    Ali ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGEA 100 % generator stator ground-fault relay • Complete ground-fault protection for gen­ erator stators that are high impedance grounded • Monitors integrity of the neutral grounding and associated wiring
    OCR Scan PDF
    ASEA Catalogue RK 65-16 E Edition 1 Single-phase
    ASEA Catalogue RK 65-16 E Edition 1 Single-phase overcurrent protective relays Used primarily as earth-fault pro­ tection. Static or electro-mechanical current relays. Different versions with respect to tripping and Indication, Contents Page General 2 Design
    OCR Scan PDF
    breaker failure relay
    I Type REB 010 Breaker failure relay 1M DB05007-EN Pag© 1 September 1992 Changed since March 1992 Data subject to change without notice ASEA BROWN BOVERI, ABB Network Control & Protection T Features Application •Local redundant protection when the circuit
    OCR Scan PDF
    radhd
    Type RADHD ASEA BROWN ÖÖYER1 1MDB04008—EN Page 1 August 1990 Changed since August 1990 Data subject to change without notice Restricted earth fault protection ABB Network Control & Protection Features Application •Prim ary side fault sensitivity down to 2-5%
    OCR Scan PDF
    rida
    RK 40-401 C om parison betw een ASEA tim e -la g o v e r- c u rr e n t re la y type RIDA w ith independent tim e -la g c h a ra c te ris tic and c o rresp o n d in g re la y s of o th er m akes CONFIDENTIAL Reg, 5621,7431 RELAY INFORMATION This c ir c u la r Is intended as a guide to ASEA s a le s re p re se n ta tiv e s
    OCR Scan PDF
    Type RAEUB ASEA BROWN 80VERI Earth fault
    Type RAEUB ASEA BROWN 80VERI Earth fault protection for power rectifiers •r**1FH ?»W" 1M bB0901^ -£ N Page 1 August 1990 Data subject to change without notice ABB Network Control & Protection (802343) Features Application • Provides earth fault protection on systems
    OCR Scan PDF
    radss
    V ASEA Inform ation RADSS Bus Differential Protection RFF-April J.2I5, RF 657-105 with sensitive Earth-Fault relays — INTRODUCTION In a resistance earthed network the available E/F current is normally less than the full-load current of the largest feeder.
    OCR Scan PDF
    4021e
    Jk mm Type REG 100 Microprocessor based ASEA BROWN BOVERI Q © ri0 r3 tO r pfOt*©CtiOH °?3'4021E S s » **« , Dat3sub*ect t0chan9e without notice ABB Relays (SE900261) Abstract Application • Protection functions included: - Phase short-circuit - Stator ground-fault
    OCR Scan PDF
    Types RN91 and REL 010 Directional earth fault
    Types RN91 and REL 010 Directional earth fault protection 1MDB06016—EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ASEA BROWN 8GVER ABB Network Control & Protection RN91 Features Application Design (2339800) •Voltage polarization down to 0.5%
    OCR Scan PDF
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three phase overcurrent and ground-fault relay independent of auxiliary power supply B03-2314E Page 1 January 1989 Changed since January 1987 Data subject to change without notic (860567; Abstract Overcurrent and ground-fault protection
    OCR Scan PDF
    racid
    it m i ASEA BROWN BOVERI ABB Relays Type RACID Micro processor based timeovercurrent and ground fault relay B03-2312 Page 1 January 1989 Changed since October 1986 Data subject to change without notice (SE900263) General Application • Two-phase or three-phase time-overcurrent