Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    VOLTAGE METERING Search Results

    VOLTAGE METERING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM106H/883
    Rochester Electronics LLC LM106 - Voltage Comparator PDF Buy
    LM710H
    Rochester Electronics LLC LM710 - Comparator, Voltage PDF Buy
    LM106H/B
    Rochester Electronics LLC LM106 - Voltage Comparator PDF Buy
    ICL8212MTY/B
    Rochester Electronics LLC Programmmable High Accuracy Voltage Detecor PDF Buy
    ICL8211MTY/883B
    Rochester Electronics LLC Programmmable High Accuracy Voltage Detecor PDF Buy

    VOLTAGE METERING Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    VOLTAGE LEVEL RELAY SM 125 230

    Abstract: spdt ac relay of 5 pins SM 125 230 SM 230 SM 115 VOLTAGE LEVEL RELAY SM 115 230 SM 115 024 SM 125-724 HF relay power supply 24 volt
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Voltage - AC Current Control Types SM 115, SM 125 • AC/DC voltage/current control relay • Current measuring range: 0.5 - 500 AAC through current metering transformer • Voltage measuring range: 0.4 - 500 VAC/DC, divided


    Original
    voltage level relay sm 125 230spdt ac relay of 5 pinssm 125 230sm 230+6sm 115voltage level relay sm 115 230sm 115 024sm 125-724hf relaypower supply 24 volt PDF

    VOLTAGE LEVEL RELAY SM 125 230

    Abstract: SM 125 230 SM 115 024 VOLTAGE LEVEL RELAY SM 125 724 relay SM-125 VOLTAGE LEVEL RELAY SM 125 024 VOLTAGE LEVEL RELAY SM 115 230 SM115024 SM 115 SM115115
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Voltage - AC Current Control Types SM 115, SM 125 • AC/DC voltage/current control relay • Current measuring range: 0.5 - 500 AAC through current metering transformer • Voltage measuring range: 0.4 - 500 VAC/DC, divided


    Original
    voltage level relay sm 125 230sm 125 230sm 115 024voltage level relay sm 125 724+6relay sm-125voltage level relay sm 125 024voltage level relay sm 115 230sm115024sm 115sm115115 PDF

    IL428

    Contextual Info: Type VMN Voltage Monitoring Resistor Networks Transient Tolerant New Voltage Dividers for Industrial Power Quality and Power Consumption Metering Applications Ratio Tolerance of 0.1% or 0.02%, Ratio TC of 10 ppm/°C or 5 ppm/°C The Type VMN Transient Tolerant Voltage Monitoring Networks are designed


    Original
    il-428il428 PDF

    Contextual Info: STEVAL-ISA036V1 5 W wide range SMPS demonstration board for metering and motor control based on the ESBT STC04IE170HP Data Brief Features • Rectified minimum input voltage Vinmin=200 V ■ Rectified maximum input voltage Vinmax=1200 V ■ Isolated output voltage Vout1=15 V / 66 mA


    Original
    steval-isa036v1stc04ie170hp PDF

    AN2454

    Abstract: STC04IE170HP AN2254 STEVAL-ISA036V1 AN2528 L4148 L6565 450v 3.3uf LL4148 st ST LL4148
    Contextual Info: STEVAL-ISA036V1 5 W wide range SMPS demonstration board for metering and motor control based on the ESBT STC04IE170HP Data Brief Features • Rectified minimum input voltage Vinmin=200 V ■ Rectified maximum input voltage Vinmax=1200 V ■ Isolated output voltage Vout1=15 V / 66 mA


    Original
    steval-isa036v1stc04ie170hpan2454an2254+6an2528l4148l6565450v 3.3ufll4148 stst ll4148 PDF

    flyback smps

    Abstract: STEVAL-ISA057V1 L6565 STC03DE220HV st smps Quasi Resonant Converter flyback STC03DE22HV
    Contextual Info: STEVAL-ISA057V1 15 W wide range SMPS for metering based on the ESBT STC03DE220HV and L6565 PWM controller Data Brief Features • Minimum input voltage: 125 VDC ■ Maximum input voltage: 1250 VDC ■ Output voltage: 5 V to 3.0 A ■ Maximum output power: 15 W


    Original
    steval-isa057v1stc03de220hvl6565en60950+4flyback smpsst smpsquasi resonant converter flybackstc03de22hv PDF

    VOLTAGE LEVEL RELAY SJ 185 724

    Abstract: VOLTAGE LEVEL RELAY SM 125 230 potentiometer 230 Transistor SJ 230 v relay SJ185 Diode SJ 24-VAC relay 9 volt voltage metering
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Voltage Control Types SJ 135, SJ 185 • Voltage metering relay with absolute scale • Measuring ranges: SJ 135: 12 mV - 500 VDC divided into 10 ranges SJ 185: 20 mV - 500 VAC divided into 8 ranges • Knob-adjustable set point


    Original
    135/sjvoltage level relay sj 185 724voltage level relay sm 125 230potentiometer 230+7transistor sj230 v relaysj185diode sj24-vacrelay 9 voltvoltage metering PDF

    VOLTAGE LEVEL RELAY SJ 185 724

    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Voltage Control Types SJ 135, SJ 185 • Voltage metering relay with absolute scale • Measuring ranges: SJ 135: 12 mV - 500 VDC divided into 10 ranges SJ 185: 20 mV - 500 VAC divided into 8 ranges • Knob-adjustable set point


    Original
    135/sjvoltage level relay sj 185 724 PDF

    IEC603-8

    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Under Voltage Control Type EUD • AC/DC under voltage metering closed circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V


    Original
    iec603-8 PDF

    PowerLogic PM710

    Abstract: A9MEM3255 PM800 PM820 schneider pm710 Benchmark RS232 RTU METSEPM1200
    Contextual Info: Basic energy metering Power Meter Series PM9 Functions and characteristics cont. Electrical characteristics Type of measurement Measurement accuracy Input-voltage characteristics Input-current characteristics Control Power Pulse output (PM9P) Current and voltage


    Original
    61557-aen50160pe86002plsed309005en+7powerlogic pm710a9mem3255pm800pm820schneider pm710benchmark rs232 rtumetsepm1200 PDF

    EUD marking

    Abstract: 5V SPDT relay 500V RELAY
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Under Voltage Control Type EUD • AC/DC under voltage metering closed circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V


    Original
    eud marking5v spdt relay500v relay PDF

    5V SPDT relay

    Abstract: control relay A1 A2
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Over Voltage Control Type EUI • AC/DC over voltage metering open circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V


    Original
    5v spdt relaycontrol relay a1 a2 PDF

    5V SPDT relay

    Abstract: eui c 230 20v PE Relay
    Contextual Info: Current and Voltage Controls 1-Phase AC/DC Over Voltage Control Type EUI • AC/DC over voltage metering open circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V


    Original
    5v spdt relayeui c 230 20vpe relay PDF

    rogowski coil integrator

    Abstract: ADE7763
    Contextual Info: Single-Phase Active and Apparent Energy Metering IC ADE7763 Data Sheet FEATURES perform active and apparent energy measurements, line-voltage period measurements, and rms calculation on the voltage and current channels. The selectable on-chip digital integrator


    Original
    iec62053-21iec62053-2260106-amo-150-ae+720-leadrs-20ade7763arszade7763arszrleval-ade7763zebrogowski coil integratorade7763 PDF

    equivalent L6565

    Abstract: AP-600 STW7NK90Z TO220 PMOS L6565 STD1LNK60Z-1 STQ2HNK60ZR-AP STQ2NK60ZR-AP STQ3NK50ZR-AP STS1HNK60
    Contextual Info: Power MOSFETs for metering High-voltage power MOSFETs the optimal choice for metering STMicroelectronics offers a wide selection of high voltage power MOSFETs for power-meter designers who require an efficient solution for either single or three-phase meters.


    Original
    stw3n150steval-isa034v1o-220o-247+11flmeter0507equivalent l6565ap-600stw7nk90zto220 pmosl6565std1lnk60z-1stq2hnk60zr-apstq2nk60zr-apstq3nk50zr-apsts1hnk60 PDF

    ade7753

    Abstract: rogowski coil integrator PS2501-1 rogowski coil analog integrator ADE77531 ADE77
    Contextual Info: Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as


    Original
    ade7753ade7753arsade7753arsrlade7753arsz+8ade7753arszrleval-ade7753zeb20-leadrogowski coil integratorps2501-1rogowski coil analog integratorade77531ade77 PDF

    ade7753

    Abstract: rms calculation by microcontroller IEC1036 62053-21 ic 8959 rogowski coil integrator PS2501-1 rogowski coil analog integrator 62053-23 reactive energy ADE7753ARSZ
    Contextual Info: Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as


    Original
    ade7753ade7753arsade7753arsrlade7753arsz1+12ade7753arszrl1eval-ade7753zeb120-leadrms calculation by microcontrolleriec103662053-21ic 8959rogowski coil integratorps2501-1rogowski coil analog integrator62053-23 reactive energyade7753arsz PDF

    0x2851EC

    Abstract: iec 60687 62053-23 reactive energy ADE7753ARSZ ADE7753 PS2501-1 rogowski coil analog integrator energy meter iec 62053-21 ADE77531
    Contextual Info: Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as


    Original
    ade7753ade7753arsade7753arsrlade7753arsz+11ade7753arszrleval-ade7753zeb20-lead0x2851eciec 6068762053-23 reactive energyps2501-1rogowski coil analog integratorenergy meteriec 62053-21ade77531 PDF

    ade7753

    Contextual Info: Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 FEATURES line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as


    Original
    ade7753ade7753arsade7753arsrlade7753arsz+3ade7753arszrleval-ade7753zeb20-lead PDF

    Contextual Info: Product introduction Medium voltage voltage transformer JDZX22-10 3/6 C Type designation Type code Designation Net weight J Voltage transformer 22 kg D Single phase Z Cast epoxy resin X With residual voltage winding 22 Design sequence 10(3/6) Rated voltage


    Original
    jdzx22-10jdzx22-3cjdzx22-6cjdzx22-10c+1b4-03 PDF

    1n5204

    Abstract: 1N5204B LNK562DN E-Shield Transformer Techniques for Low EMI EE16 EE16 NC-2H DI-164 di164 NC-2H 1N4007GP
    Contextual Info: DI-164 Design Idea LinkSwitch-LP 1 W, Low Cost, Linear Replacement Power Supply Eliminates Need For Input Electrolytic Capacitor Application Device Power Output Input Voltage Output Voltage Topology Metering LNK562DN 0.98 W 85 - 265 VAC 7V Flyback Design Highlights


    Original
    di-164lnk562dn1n52041n5204b+6e-shield transformer techniques for low emiee16ee16 nc-2hdi164nc-2h1n4007gp PDF

    Contextual Info: Product introduction Medium voltage voltage transformer JDZX22-10 3/6 C2G-A(N) Type designation Type code Designation Net weight J Voltage transformer 22 kg D Single phase Z Cast epoxy resin X With residual voltage winding 22 Design sequence 10(3/6) Rated voltage


    Original
    jdzx22-10jdzx22-3c2g-ajdzx22-3c2g-njdzx22-6c2g-a+4jdzx22-6c2g-njdzx22-10c2g-ajdzx22-10c2g-n1yla000124-rev PDF

    Contextual Info: Product introduction Medium voltage voltage transformer JDZX22-10 3/6 C1G-A(N) Type designation Type code Designation Net weight J Voltage transformer 22 kg D Single phase Z Cast epoxy resin X With residual voltage winding 22 Design sequence 10(3/6) Rated voltage


    Original
    jdzx22-10jdzx22-3c1g-ajdzx22-3c1g-njdzx22-6c1g-a+4jdzx22-6c1g-njdzx22-10c1g-ajdzx22-10c1g-n1yla000122-rev PDF

    rogowski coil analog integrator

    Abstract: 0xE401 0xE228 rogowski coil integrator ADE7816
    Contextual Info: Six Current Channels, One Voltage Channel Energy Metering IC ADE7816 Data Sheet voltage and current. The device incorporates seven sigma-delta Σ-Δ ADCs with a high accuracy energy measurement core. The six current input channels allow multiple loads to be measured


    Original
    ade78165-06-2011-acp-40-10d10390-0-2/12+4rogowski coil analog integrator0xe4010xe228rogowski coil integrator PDF