acbel api 88
Abstract: acbel api 8 API-8570 RS485 12AWG TXDRS485
Contextual Info: 24V / 70A API-8570 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac and auto recovery when mains have recovered.
|
Original
|
api-857090vacrs48545dba+7api-8570date00-240v50/60hzacbel api 88acbel api 812awgtxdrs485
|
PDF
|
API-201-980120
Abstract: 48V50A 48V battery 50a rectifier circuit Earth leakage elcon RS485 bus 12AWG
Contextual Info: -48V / 50A API-201-980120 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac and auto recovery when mains have recovered.
|
Original
|
api-201-98012090vacrs485100mhz+13150khz200khz500khz30mhz-54vdc60vdc48v50a48v battery50a rectifier circuitearth leakageelconrs485 bus12awg
|
PDF
|
2 PHASE 220V AC to 220V DC regulated switching
Abstract: API-7200 3 PHASE 220V AC to 220V DC regulated switching 48v 100a 701-12-02107 TXDRS485 elcon API7 1 PHASE 220V AC to 220V AC regulated switching acbel api 8
Contextual Info: -48V/100A API-7200 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac 3 3W /156Vac(3 4W) and auto recovery when mains have
|
Original
|
-48v/100aapi-720090vac/156vac+13rs48560vdc45dba380vac2 phase 220v ac to 220v dc regulated switching3 phase 220v ac to 220v dc regulated switching48v 100a701-12-02107txdrs485elconapi71 phase 220v ac to 220v ac regulated switchingacbel api 8
|
PDF
|
API-7200
Abstract: 48v 100a 3 PHASE 220V AC to 220V DC regulated switching API7 1 PHASE 220V AC to 220V AC regulated switching 2 PHASE 220V AC to 220V DC regulated switching API7200
Contextual Info: -48V/100A API-7200 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac 3 3W /156Vac(3 4W) and auto recovery when mains have
|
Original
|
-48v/100aapi-720090vac/156vac+10rs48560vdc45dba380vac48v 100a3 phase 220v ac to 220v dc regulated switchingapi71 phase 220v ac to 220v ac regulated switching2 phase 220v ac to 220v dc regulated switchingapi7200
|
PDF
|
API-201-980120
Abstract: 48V50A elcon 12AWG TXDRS485
Contextual Info: -48V / 50A API-201-980120 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac and auto recovery when mains have recovered.
|
Original
|
api-201-98012090vacrs485100mhz+10150khz200khz500khz30mhz-54vdc60vdc48v50aelcon12awgtxdrs485
|
PDF
|
elcon
Abstract: acbel api 88 12AWG API-8570 701-12-02107
Contextual Info: 24V / 70A API-8570 Features: Protections: Input Transient Voltage Protection: MOV is installed to protect AC voltage transient and spike. AC Mains Low: Rectifiers automatically shut down when input voltage falls below 90Vac and auto recovery when mains have recovered.
|
Original
|
api-857090vacrs48530vdc+845dbaapi-8570date00-240v50/60hzelconacbel api 8812awg701-12-02107
|
PDF
|