Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRIP COIL Search Results

    TRIP COIL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DRV201YFMR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 Visit Texas Instruments Buy
    DRV201AYMBR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 Visit Texas Instruments Buy
    DRV201YFMT
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 Visit Texas Instruments
    DRV201AYMBRB
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 Visit Texas Instruments Buy
    DRV201YMBR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 Visit Texas Instruments Buy

    TRIP COIL Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    FK1250

    Abstract: FK1600 GE Switch Disconnector FG630 SMR1G iec 947-4-1 400v FE250 smr2 famsm2 FK800 tripping unit Magnetic setting Im pick-up band
    Contextual Info: GE Consumer & Industrial Power Protection Record Plus Trip Units GE imagination at work Record Plus Thermal magnetic & Magnetic only trip units B.2 FD frame: LTM, LTMD, GTM, Mag BreakTM B.6 FE frame: LTM, LTMD, GTM, Mag BreakTM Electronic trip units B.11 FE160 and FE250 breakers SMR1 types


    Original
    fe160fe250fg400fg630+9fk800fk1250fk1600ge switch disconnectorsmr1giec 947-4-1 400vsmr2 famsm2fk800 tripping unitmagnetic setting im pick-up band PDF

    TEMPERATURE CONTROLLER

    Abstract: AD202 4-20ma equivalent transistor 2N1711 op177 558C TMP01 TMP01ES TMP01FJ TMP01FJ2 TMP01FP
    Contextual Info: a FEATURES –558C to +1258C –678F to +2578F Operation 61.08C Accuracy Over Temperature (typ) Temperature-Proportional Voltage Output User-Programmable Temperature Trip Points User-Programmable Hysteresis 20 mA Open Collector Trip Point Outputs TTL/CMOS Compatible


    Original
    1258c2578ftmp01c00333+9temperature controllerad202 4-20maequivalent transistor 2n1711op177558ctmp01estmp01fjtmp01fj2tmp01fp PDF

    IRF1307

    Abstract: equivalent transistor 2N1711 COTO 0019 triac MOC3011 TIP 43c transistor
    Contextual Info: BACK a FEATURES –55؇C to +125؇C –67؇F to +257؇F Operation ؎1.0؇C Accuracy Over Temperature (typ) Temperature-Proportional Voltage Output User Programmable Temperature Trip Points User Programmable Hysteresis 20 mA Open Collector Trip Point Outputs


    Original
    tmp01c1802birf1307equivalent transistor 2n1711+3coto 0019triac moc3011tip 43c transistor PDF

    shunt trip

    Abstract: Elevator motors Ferraz ShawmuT AMPTRAP Ferraz Shawmut fusible 3PDT relay ES2T20R1KRN2A2 8727 Ferraz fuse 125 A 2000 V UL512
    Contextual Info: ENGINEERED SWITCHES FUSIBLE SHUNT TRIP DISCONNECT SWITCHES Ferraz Shawmut’s Engineered Switches offer modular industrial control panels featuring a fusible shunt trip to allow for remote disconnection. An array of available options allows for maximum functionality to be built


    Original
    f-69100br-fstw-001shunt tripelevator motors+8ferraz shawmut amptrapferraz shawmutfusible3pdt relayes2t20r1krn2a28727ferraz fuse 125 a 2000 vul512 PDF

    sper1c1

    Abstract: sper 1c1 1MDB14003-EN sper 1c2 data about circuit breakers and relays 002AA SPER about the dc relay 002-AA A33A
    Contextual Info: Type SPER 1M DB08008-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice Trip circuit supervision relay ABB Network Control & Protection Features •Continuous supervision of circuit breaker trip circuits or other vital control circuits


    OCR Scan
    1mdb08008-en002-aa003-aa1mdb14003-en+8sper1c1sper 1c1sper 1c2data about circuit breakers and relays002aasperabout the dc relaya33a PDF

    Contextual Info: ANALOG DEVICES FEATURES —55°C to +150°C —60°F to +300°F Operation ±0.5°C Accuracy Over Temperature (typ) Temperature-Proportional Voltage Output User Programmable Temperature Trip Points User Programmable Hysteresis 20 mA Open Collector Trip Point Outputs


    OCR Scan
    tmp-01 PDF

    24C1024

    Abstract: 24C1024 EEPROM Watchdog Timer WD str 2062 4040 counter 8051 data loggers HC4040 Rogowski Coil design rogowski coil integrator teridian application notes metering
    Contextual Info: 71M6403 Electronic Trip Unit SEPTEMBER 2006 GENERAL DESCRIPTION FEATURES The Teridian 71M6403 is an electronic trip unit ETU system-on-chip device for air circuit breakers (ACB), molded case circuit breakers (MCCB) and other types of intelligent switchgear. Utilizing Teridian’s


    Original
    71m640322-bit32-bit24c1024+924c1024 eepromwatchdog timer wdstr 20624040 counter8051 data loggershc4040rogowski coil designrogowski coil integratorteridian application notes metering PDF

    triac driver opto moc3021

    Abstract: coto relay 8ch pnp DARLINGTON TRANSISTOR ARRAY "transistor count" adm485 schematic diagram for heater power controller ir sensor interface with 8051 opto-isolator h11l1 array C2063 temperature sensor interface with 8051 8ch DARLINGTON TRANSISTOR ARRAY
    Contextual Info: a FEATURES –55؇C to +125؇C –67؇F to +257؇F Operation ؎1.0؇C Accuracy Over Temperature (typ) Temperature-Proportional Voltage Output User Programmable Temperature Trip Points User Programmable Hysteresis 20 mA Open Collector Trip Point Outputs TTL/CMOS Compatible


    Original
    tmp01triac driver opto moc3021coto relay8ch pnp darlington transistor array+7transistor count" adm485schematic diagram for heater power controllerir sensor interface with 8051opto-isolator h11l1 arrayc2063temperature sensor interface with 80518ch darlington transistor array PDF

    8-pin optoisolator

    Abstract: IRGBC Precision triac control thermostat equivalent transistor 2N1711 IL300XC TMP01F TMP01 TMP01EP TIP 43c transistor TMP01FJ
    Contextual Info: a FEATURES –55؇C to +125؇C –67؇F to +257؇F Operation ؎1.0؇C Accuracy Over Temperature (typ) Temperature-Proportional Voltage Output User Programmable Temperature Trip Points User Programmable Hysteresis 20 mA Open Collector Trip Point Outputs TTL/CMOS Compatible


    Original
    tmp018-pin optoisolatorirgbcprecision triac control thermostat+6equivalent transistor 2n1711il300xctmp01ftmp01eptip 43c transistortmp01fj PDF

    LM358M

    Abstract: DO1608C-103 LM358 LM358 op-amp 511k opamp LM358 SP6648
    Contextual Info: SP6648 with LM358 OpAmp 2AA to 1W LumiLED VBATT 1.6 to 3.2V 2.2V LBI TRIP 10uH Coilcraft DO1608C-103 R1 = R2* LBI Trip V/0.62V - 1 C1 10uF Ceramic R1 511k 1 2 C4 0.1uF R2 200k 3 4 SHDN 5 RLIM 1.87K L1 10uH VBATT LBI VOUT SP6648 LX LBON RLIM SHDN PGND GND


    Original
    sp6648lm358do1608c-103350ma+4lm358mlm358 op-amp511kopamp lm358 PDF

    Contextual Info: Trip circuit supervision relay Type RXTCS Station Automation & Protection ABB Substation Automation Products Features l l l l l l l l Continuous supervision of complete trip circuit independent of the circuit breaker position. Detects faults in the supervised circuits, such as


    Original
    003-ben001-ben1mdb10202 PDF

    LTC1154

    Contextual Info: LTC1153 Auto-Reset Electronic Circuit Breaker DESCRIPTIO U FEATURES • ■ ■ ■ ■ ■ ■ ■ ■ ■ Programmable Trip Delay: 15µs to >100ms Programmable Trip Current: 1mA to >20A Programmbale Auto-Reset Time: 1ms to >10 sec. 4.5V to 18V Supply Range


    Original
    ltc1153100msltc1154 PDF

    cd 1619 CP

    Abstract: 12v lamp driver Marking IRLD024 relay 24v 30a keystone carbon thermistor rl2006 24V 30A Relay data about circuit breakers and relays IMS026 LTC1154 LTC1153
    Contextual Info: LTC1153 Auto-Reset Electronic Circuit Breaker U DESCRIPTIO FEATURES • ■ ■ ■ ■ ■ ■ ■ ■ ■ Programmable Trip Delay: 15µs to >100ms Programmable Trip Current: 1mA to >20A Programmbale Auto-Reset Time: 1ms to >10 sec. 4.5V to 18V Supply Range


    Original
    ltc1153100mscd 1619 cp12v lamp driver+7marking irld024relay 24v 30akeystone carbon thermistor rl200624v 30a relaydata about circuit breakers and relaysims026ltc1154 PDF

    Rogowski

    Abstract: mccb rogowski coil integrator Rogowski Coil 4040 counter mccb DATASHEET MARKING 3D regulator switchgear 71M6403 mccb circuit breaker DATASHEET
    Contextual Info: Product Brief 71M6403 Electronic Trip Unit The Teridian 71M6403 is an electronic trip unit ETU system-on-chip device for air circuit breakers (ACB), molded case circuit breakers (MCCB) and other types of intelligent switchgear. Utilizing Teridian’s patented Single Converter Technology , the 71M6403


    Original
    71m640322-bit32-bitrogowski+8mccbrogowski coil integratorrogowski coil4040 countermccb datasheetmarking 3d regulatorswitchgearmccb circuit breaker datasheet PDF

    ABB CIRCUIT BREAKER

    Abstract: B03-9175E B03-8360E trc 4800 4800 application circuit abb 220V DC relay abb 40 relay trip coil 220v ac circuit breaker BROWN BOVERI max current relay
    Contextual Info: V Ék II 91 /M l» Type TRC 4800 B03-8360E Trip-circuit monitoring relay Page 1 October 1986 Changed since January 1985 Data subject to change without notic ASEA BROWN BOVERI ABB Relays Abstract *s Monitors auxiliary operate contacts Monitors the whole trip-circuit indepen­


    OCR Scan
    b03-8360eb03-9175eb03-9382es-721+8abb circuit breakertrc 48004800 application circuitabb 220v dc relayabb 40 relaytrip coil220v ac circuit breakerbrown boveri max current relay PDF

    MIL-STD-38510

    Contextual Info: I r A PL| CORPORATION L C H u m relay group Hybrid DC Voltage Sensor VSH-594 ELECTRICAL SPECIFICATIONS Input Parameters Operation: 20 to 30 VDC a. Input b. Under voltage trip point range 1 to 50 VDC adjustable c. Over voltage trip point range 5 to 55 VDC (adjustable)


    OCR Scan
    vsh-594mil-r-6106122ktomil-std-883+1mil-std-38510 PDF

    Carlingswitch

    Abstract: 250 amp breaker 300v barrier type screw terminal carlingswitch 620 multi poles switch
    Contextual Info: Time Delay Values E-Series DC AC Instantaneous 10000 50/60 Hz INSTANTANEOUS CURVE NO. 20 D.C. INSTANTANEOUS CURVE NO. 10 1000 TRIP TIME IN SECONDS 1000 TRIP TIME IN SECONDS 10000 100 10 1 .1 .01 .001 100 200 300 400 500 600 700 800 900 1000 1100 .1 .001


    Original
    carlingswitch250 amp breaker300v barrier type screw terminalcarlingswitch 620+1multi poles switch PDF

    T1C 106D

    Abstract: spdt 12v 50a relay ISO8846 UL-489 Carlingswitch circuit breaker c-series VDE reg. -Nr 0001 AA3 plug
    Contextual Info: Time Delay Values A, B, C & D-Series AC Instantaneous 10000 50/60 Hz INSTANTANEOUS CURVE NO. 20 D.C. INSTANTANEOUS CURVE NO. 10 1000 TRIP TIME IN SECONDS TRIP TIME IN SECONDS 1000 100 10 1 .1 .1 .01 100 125 200 300 400 500 600 700 800 900 1000 1100 1200


    Original
    t1c 106dspdt 12v 50a relayiso8846ul-489+3carlingswitch circuit breaker c-seriesvde reg. -nr 0001aa3 plug PDF

    T1C 106D

    Abstract: mil-std-202 method 107d Carlingswitch circuit breaker c-series transformer 220 volts 60 Hz specifications 120v AC to 12V dc transformer Carlingswitch 6710 starter VDE 0660 3 phase switch 250 amp breaker 380 volt 50 hz
    Contextual Info: Time Delay Values A, B, C & D-Series AC Instantaneous 10000 50/60 Hz INSTANTANEOUS CURVE NO. 20 D.C. INSTANTANEOUS CURVE NO. 10 1000 TRIP TIME IN SECONDS TRIP TIME IN SECONDS 1000 100 10 1 .1 .1 .01 100 125 200 300 400 500 600 700 800 900 1000 1100 1200


    Original
    ul489t1c 106dmil-std-202 method 107dcarlingswitch circuit breaker c-series+7transformer 220 volts 60 hz specifications120v ac to 12v dc transformercarlingswitch6710 startervde 0660 3 phase switch250 amp breaker380 volt 50 hz PDF

    Carlingswitch circuit breaker c-series

    Abstract: rocker switch inrush current duration 120v AC to 12V dc transformer Carlingswitch Carlingswitch circuit breaker 65vdc MIL-C-55629 A125a transformer 220 volts 60 Hz specifications VDE 0660 107D
    Contextual Info: Time Delay Values A, B, C & D-Series AC Instantaneous 10000 50/60 Hz INSTANTANEOUS CURVE NO. 20 D.C. INSTANTANEOUS CURVE NO. 10 1000 TRIP TIME IN SECONDS TRIP TIME IN SECONDS 1000 100 10 1 .1 .1 .01 100 125 200 300 400 500 600 700 800 900 1000 1100 1200


    Original
    carlingswitch circuit breaker c-seriesrocker switch inrush current duration120v ac to 12v dc transformercarlingswitch+6carlingswitch circuit breaker 65vdcmil-c-55629a125atransformer 220 volts 60 hz specificationsvde 0660107d PDF

    12v-1A Relay

    Contextual Info: /T in m j K L m ß TECHNOLOGY LTC1153 Auto-Reset Electronic Circuit Breaker FCRTURCS D € S C R IP T IO n • Programmable Trip Delay: 15|os to >100ms ■ Programmable Trip Current: 1mA to >20A ■ Programmbale Auto-Reset Time: 1ms to >10 sec. ■ 4.5V to 18V Supply Range


    OCR Scan
    ltc1153100ms12v-1a relay PDF

    26946

    Abstract: 26924 26960 26948 shunt trip 125vdc shunt trip coil 26947 26923 415VAC OF - 26924
    Contextual Info: Electrical auxiliaries for 2 and 4 pole RMGs Arrangement of auxiliaries O F + + + + O F O F Auxiliary switch OF Undervoltage trip module MN Shunt trip module MX Auxiliary switch OF.S RCD + + MX or MN + + O F S R M G MX or MN O F S R M G MX or MN + O F S +


    Original
    26946269242696026948+6shunt trip125vdc shunt trip coil2694726923415vacof - 26924 PDF

    24 VDC 400A AUTOMATIC FUSE

    Abstract: shunt trip relay 240v 60a Littelfuse LPS2 lps4 LPS1T48R1KN1U 120v power amp circuits LPS3
    Contextual Info: LPS Series POWR-SWITCH STANDARD FEATURES NEW • 600V 3-pole fuse power switch ■ 200,000 RMS interrupting rating ■ Shunt trip 120V ■ Control power terminal block ■ Ground lug per NEC ■ Class J fuse block ■ NEMA 1 enclosures OPTIONAL FEATURES The Littelfuse POWR-Switch provides a simple and economical solution for applications that require selective coordination and shunt trip capabilities. Common applications include


    Original
    250kcmil24 vdc 400a automatic fuseshunt triprelay 240v 60a+5littelfuse lps2lps4lps1t48r1kn1u120v power amp circuitslps3 PDF

    100-C43

    Abstract: 193-EA1FB 193-EA4EB 193-EA1GB 193-EA1CB 193-EA4FB 193-EA1EB 193-EA5KE 193-EA1DB 193-EA4DB
    Contextual Info: Electronic Motor Protection Relays Bulletin 193-E 193-EB also includes: • Trip Class 10, 15 or 20 selectable • Ground Fault Protection • Jam/Stall Protection Product Selection . 5-3 Accessories


    Original
    193-e193-eb193-ea193-es+15150mw100-c60193-epm1193-epm2193-epm3100-c43193-ea1fb193-ea4eb193-ea1gb193-ea1cb193-ea4fb193-ea1eb193-ea5ke193-ea1db193-ea4db PDF