Starting Current 7.5KW Motor 440v
Abstract: 7.5KW 3 phase motor 440v contactor and overload start stop 1 KW induction motor 440v 3phase OVERLOAD RELAY bs5424 15 KW induction motor 440v 3phase 0.5 hp 3-PHASE induction motor 440V 50HZ dol starter
Contextual Info: Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
|
Original
|
415vacbs5424iec158vde0660+11220/240v15v/440vstarting current 7.5kw motor 440v7.5kw 3 phase motor 440vcontactor and overload start stop1 kw induction motor 440v 3phaseoverload relay15 kw induction motor 440v 3phase0.5 hp 3-phase induction motor440v 50hzdol starter
|
PDF
|
VDE0660
Abstract: 380V 415v 15kw motor vde-0660 3 phase, 415v and 11 kw induction motor 15 KW induction motor 440v 3phase Starting Current 7.5KW Motor 440v IEC292 380V 415v motor 3 phase, 415v and 37 kw motor single phase dol motor starter
Contextual Info: Issued March 1997 232-3355 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
|
Original
|
415vacbs4941iec292vde0660+12220/240v380/440vbs5424iec158-1380v 415v 15kw motorvde-06603 phase, 415v and 11 kw induction motor15 kw induction motor 440v 3phasestarting current 7.5kw motor 440v380v 415v motor3 phase, 415v and 37 kw motorsingle phase dol motor starter
|
PDF
|
15 KW induction motor 440v 3phase
Abstract: Starting Current 7.5KW Motor 440v 3 phase, 415v and 37 kw motor 7.5KW 3 phase motor 440v contactor coils 415v contactor 220V 3 phase 3 phase, 415v and 15 kw motor DOL starting of 3-Phase induction motor 380V 415v motor 100 hp contactor and overload start stop
Contextual Info: Issued March 1997 232-4493 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
|
Original
|
415vacbs5424iec158vde0660+12220/240v15v/440v15 kw induction motor 440v 3phasestarting current 7.5kw motor 440v3 phase, 415v and 37 kw motor7.5kw 3 phase motor 440vcontactor coils 415vcontactor 220v 3 phase3 phase, 415v and 15 kw motordol starting of 3-phase induction motor380v 415v motor 100 hpcontactor and overload start stop
|
PDF
|
A9A26929
Abstract: DC126A Schneider Electric ic60 240-415VAC DC-12 AC123 240-415V
Contextual Info: Product data sheet Characteristics A9A26929 auxiliary contact iOF/SD+OF - 240.415VAC 24.130VDC - 2OC - for iC60 iID Range of product IC60 IID ISW-NA Device short name IOF/SD+OF Signal contacts composition 2 C/O [Ie] rated operational current AC-12: 3 A AC 50/60 Hz 415 V
|
Original
|
a9a26929415vac130vdcac-12+6dc-12dc126aschneider electric ic60240-415vacac123240-415v
|
PDF
|
7.5KW 3 phase motor 440v
Abstract: Starting Current 7.5KW Motor 440v 15 KW induction motor 440v 3phase 380V 415v motor bs88 fuse 3 phase, 415v and 37 kw motor 0.5 hp 3-PHASE induction motor IEC158 VDE0660 11 KW 3-phase motor weight
Contextual Info: Issued March 1994 017-064 Data Pack B Data Sheet Direct on line DOL starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
|
Original
|
415vacbs5424iec158vde0660+10220/240v15v/440v7.5kw 3 phase motor 440vstarting current 7.5kw motor 440v15 kw induction motor 440v 3phase380v 415v motorbs88 fuse3 phase, 415v and 37 kw motor0.5 hp 3-phase induction motor11 kw 3-phase motor weight
|
PDF
|
|
Contextual Info: SB20 Level controller or power interface module with alarm sounder Primary output can directly control motors up to 2HP cosF 0.4-0.5 single phase 2 SPCO relay outputs Alarm indicator LED and Beeper 1, 2 or 3 sensor inputs 240 or 415Vac supply DIN rail mounting
|
Original
|
415vaciso9001 |
PDF
|
|
Contextual Info: SM20 Level controller or high power interface module Primary output can directly control motors up to 2HP cosF 0.4-0.5 single phase 2 SPCO relay outputs 12Vac sensor voltage 1, 2 or 3 sensor inputs 240 or 415Vac supply DIN rail mounting Technical Specification
|
Original
|
12vac415vac220/240vaciso9001 |
PDF
|
26924
Abstract: 26929 26927 415Vac 18mm 125VDC 415v 48VDC C120
Contextual Info: Electrical auxiliaries For DPN, C60 and C120 SD fault indicating switch Part No. 26927 94 92 91 Width in 18mm SP ways 0.5 Contact rating Auxiliary contact changes when device trips, with front face indication. 26927 V 240Vac 415Vac 24Vdc 48Vdc 125Vdc (A)
|
Original
|
240vac415vac24vdc48vdc+7125vdc26924269292692718mm415vc120
|
PDF
|
DSD30
Abstract: BS1361
Contextual Info: Issued November 1983 B5112 Pullcap fuses Stocknumbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This means that it is ideal for applications where high
|
Original
|
b5112dsd30415vac250vdc+1bs1361
|
PDF
|
VDE0660
Abstract: Starting Current 7.5KW Motor 440v vde-0660 380V 415v motor 3 phase, 415v and 11 kw induction motor bs5424 IEC158-1 IEC158 OVERLOAD RELAY 1 KW induction motor 440v 3phase
Contextual Info: Issued November 1990 011-044 Data Pack B Direct on line dol starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
|
Original
|
415vacbs4941iec292vde0660+11220/240v380/440vbs5424iec158-1starting current 7.5kw motor 440vvde-0660380v 415v motor3 phase, 415v and 11 kw induction motoriec158overload relay1 kw induction motor 440v 3phase
|
PDF
|
BS1361
Abstract: BS88 fuselink D3030 F192 FUSELINK TO BS88 PART 1
Contextual Info: Issued November 1983 005-112 Data Pack B Pullcap fuses Data Sheet RS stock numbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This
|
Original
|
415vac250vdcbs1361bs88+4fuselinkd3030f192fuselink to bs88 part 1
|
PDF
|
380V 415v motor 100 hp
Abstract: 380V 415v motor 380V 415v motor FLA Allen-Bradley 1333 1333 AC Drives HP 1121 A 415Vac KVA 25 415 3 bulletin 1333
Contextual Info: ^ ¡g jü ^ ALLEN-BRADLEY A ROCKW ELL INTERNATIONAL COMPANY Supplemental Instructions Bulletin 1333 Series B Adjustable Frequency AC Motor Drive 380V, 415VAC, 25-50 HP Supplemental Instructions Bulletin 1333 25 through 50 HP, 380/415V Introduction This supplement is intended to be used with the Bulletin 1333 Series B
|
OCR Scan
|
415vac380/415v380v 415v motor 100 hp380v 415v motor+6380v 415v motor flaallen-bradley 13331333 ac driveshp 1121 akva 25 415 3bulletin 1333
|
PDF
|
A9A26927
Abstract: 240-415VAC DC-12 DC126A Schneider Electric ic60
Contextual Info: Product data sheet Characteristics A9A26927 auxiliary contact iSD - 240.415VAC 24.130VDC - Fault contact - for Ic60 Range of product IC60 IID ISW-NA Device short name ISD Signal contacts composition 1 C/O [Ie] rated operational current AC-12: 3 A AC 50/60 Hz 415 V
|
Original
|
a9a26927415vac130vdcac-12+4dc-12240-415vacdc126aschneider electric ic60
|
PDF
|
BS1361
Abstract: BS88 FUSELINK TO BS88 PART 1 D3030 F192 f192 transformer 415Vac
Contextual Info: Issued March 1997 232-2649 Data Pack B Pullcap fuses Data Sheet RS stock numbers 413-787 to 413-850 The pullcap range of fuselinks is ASTA CERTIFIED to BS88 Part 1 1975 for a breaking capacity or rupturing capacity of 80kA at 415Vac and 40kA at 250Vdc. This
|
Original
|
415vac250vdcbs1361bs88+4fuselink to bs88 part 1d3030f192f192 transformer
|
PDF
|
|
|
cc3001
Abstract: GEN300-11 IS420 3.3KW motor IS510 GEN-300-11 DIODE ZENER BZW 03 protocol rs485 GEN20-165 GEN-600-5
Contextual Info: TECHNICAL MANUAL FOR 2U GENESYSTM 3.3kW Programmable DC Power Supplies Document: 83-503-001 Rev E TDK-Lambda Americas Inc. 405 Essex Road, Neptune, NJ 07753 Tel: 732 922-9300 Fax: (732) 922-9334 Web: www.us.tdk-lambda.com/hp GENESYSTM Manual Supplement FOR UNITS EQUIPPED WITH “IEMD” OPTION,
|
Original
|
190-240vac600vac400vdc380-415vac+10cc3001gen300-11is4203.3kw motoris510gen-300-11diode zener bzw 03protocol rs485gen20-165gen-600-5
|
PDF
|
earth leakage circuit
Abstract: 15.927 Breaker FI 15.932 15.930
Contextual Info: FI EARTH LEAKAGE CIRCUIT BREAKERS FI compact Earth Leakage Circuit Breakers detect and interrupt earth ground faults. They are VDE approved for the European system of protecting people, animals, equipment and property from dangerous line-to-ground and shock
|
Original
|
300maearth leakage circuit15.927breaker fi+215.93215.930
|
PDF
|
415Va
Abstract: D1016 contactor coils 24v P1625 D558 PBA-40A IEC/EN60947-4-1 CSA22 DC-13 EN60947-4-1
Contextual Info: P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 PBC RoHS Ready Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approval files of
|
Original
|
e38802415vacpba-11bpba-20b+10415vad1016contactor coils 24vp1625d558pba-40aiec/en60947-4-1csa22dc-13en60947-4-1
|
PDF
|
Airpax LMLK
Abstract: Airpax IEL Airpax circuit breaker cross reference Airpax LEL LMLK Airpax relay Airpax marine circuit breaker circuit breaker airpax 209 amps bullet breaker panel Airpax cel
Contextual Info: Single Pole Circuit Breakers Multi-Pole Circuit Breakers BX Style Circuit Breakers High-Current Magnetic Circuit Breakers Panel Seal Circuit Breakers 153 154 155 156 157 Rocker Handles 158 Configurations 159 Mid-Trip and Snap-In Options 161 Remote Operated Circuit Breakers
|
Original
|
airpax lmlkairpax ielairpax circuit breaker cross referenceairpax lel+6lmlkairpax relayairpax marine circuit breakercircuit breaker airpax 209 ampsbullet breaker panelairpax cel
|
PDF
|
MD 1010 manual
Abstract: AEM31 CM23 460VAC measuring power in single phase supply using 3 volts INSTRUMENT TRANSFORMERS - 600 VOLT CLASS 70Wx
Contextual Info: AEM31 PANEL INSTRUCTIONS 1 SAFETY 3.1 CONNECTION OF THE VOLTAGE INPUT This instrument was manufactured and tested in compliance with class 2 IEC 1010 and VDE 411 standards, in accordance with group B VDE 0110 standards for operating voltages up to 250 VACrms phase to neutral. It is suitable for
|
Original
|
aem31md 1010 manualcm23460vac+3measuring power in single phase supply using 3 voltsinstrument transformers - 600 volt class70wx
|
PDF
|
telemecanique contactor catalogue
Abstract: telemecanique star delta starter bs88 zs levels HRC fuse gg GEC BS88-2 15KW motor telemecanique star delta starter table NIT16 gec mte axto overload BS88 fuse curve hbc
Contextual Info: Issued March 1997 232-3608 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.
|
Original
|
iec269rs20hrs32hrs63h+11rs100htelemecanique contactor cataloguetelemecanique star delta starterbs88 zs levelshrc fuse gg gecbs88-215kw motortelemecanique star delta starter tablenit16 gecmte axto overloadbs88 fuse curve hbc
|
PDF
|
HT12E HT12D
Abstract: Panasonic RELAY Cross Reference NEC OMRON N80C196KC16 MOS248 TDA2086A GOULD 500 COLOUR LCD DIGITAL STORAGE OSCILLOSCOPE 1NA114AP ICM72171 SL443A nec matrix Vacuum tube display
Contextual Info: Issued July 1996 021-928 Data Packs A-K RS data sheet/semiconductor manufacturers data sheet index Data Sheet Introduction RS data sheets form a unique source of detailed information regarding technical specifications, absolute maximum ratings and applications for engineers and designers working with RS products.
|
Original
|
ht12e ht12dpanasonic relay cross reference nec omronn80c196kc16mos248+6tda2086agould 500 colour lcd digital storage oscilloscope1na114apicm72171sl443anec matrix vacuum tube display
|
PDF
|
telemecanique contactor catalogue
Abstract: telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
Contextual Info: Issued March 1992 012-659 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.
|
Original
|
iec269rs20hrs32hrs63h+11rs100htelemecanique contactor cataloguetelemecanique star delta starterhrc fuse gg gecbs88 zs levelsmte axto overloadnit16 gecgec switchgeartia32mte max0tis63m80 curve
|
PDF
|
PowerLogic PM710
Abstract: LC2K0901 SE5855 LC1K0910 PM820MG SE585 Merlin Gerin PM710 MP20B schneider pm710 telemecanique contactor catalogue
Contextual Info: SE5855 Select "Edition 4" 3/5/06 Edition 4 12:40 pm Page 1 Product catalogue 06 Residential Commercial Industrial SE5855 Select "Edition 4" 3/5/06 12:40 pm Page 2 Our mission is to provide you with convenience and quality through our S-elect range. S-elect consists of over 1000 of our
|
Original
|
se5855powerlogic pm710lc2k0901lc1k0910+6pm820mgse585merlin gerin pm710mp20bschneider pm710telemecanique contactor catalogue
|
PDF
|
Mitsubishi th-n20kp
Abstract: AD16-22DS Kyoritsu 3301 kyoritsu model 1008 terasaki xh100ns KSD 166 16a 250v ksd 302 250v, 10a carlo gavazzi VDE 0660 ksd 250v 10a EEL 22w transformer
Contextual Info: CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar Support Power Supply MCB Bar Contactor / Thermal Overload Relay / Auxiliary Contact Terminal Block Din Rail Terminal Block C/W Cover Terminal Block Float Switch Foot Switch Warning Light / Tower Light Hour Run Meter / Time Switch / Weather Proof Isolating Switch
|
Original
|
100hp125hp112kw150hp+16135kw180hp150kw200hp164kw220hpmitsubishi th-n20kpad16-22dskyoritsu 3301kyoritsu model 1008terasaki xh100nsksd 166 16a 250vksd 302 250v, 10acarlo gavazzi vde 0660ksd 250v 10aeel 22w transformer
|
PDF
|