Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TLSGD2 Search Results

    Documents mentioning TLSGD2

    Document Partial File Text Tags Type PDF
    Rockwell Automation Functional Safety Data Sheet
    Rockwell Automation Functional Safety Data Sheet IMPORTANT: The data given cannot be regarded as valid unless proper account is taken of the relevant * notes. PFHD Type Interlock Switches Guard Locking Switches Hinge Interlocking Switches Prosafe Trapped Key
    Original PDF
    iec 60947-5-3
    Safety Switches Guard Locking Switches TLS-Z GD2 Specifications Standards IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN ISO 13849-1, IEC 62061, ISO 14119 Safety Classification PLe per ISO 13849-1, SIL 3 per IEC 61508 and IEC 62061, PDF-M per IEC 60947-5-3 Functional Safety Data (related
    Original PDF
    tls-gd2
    Interlock Switches Guard Locking Switches TLS-GD2 Specifications Shown with optional Key Release Kit Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for
    Original PDF
    440a
    Accessories 440A-A07265…440A-A09197 Item 14-2 Description Catalogue Number Blanking Plug, M20 Conduit 440A-A07265 Cable Grip, M16 Conduit Accommodates Cable Diameter 4mm (0.16in) to 7mm (0.27in) 440A-A09004 Security Bit 440A-A09015 Screwdriver Including Security Bit
    Original PDF
    msr6r/t
    Safeguarding Applications Guard Locking Interlocks TLS3-GD2, Bulletin 800, MSR6R/T, Bulletin 100S, Dual Channel 24V AC/DC, 110V AC, 230V AC Lock Release Momentary Push Button Start K1(Aux) Momentary Push Button K2 (Aux) L1 L2 L3 K1 (Aux) Stop Momentary Push Button
    Original PDF
    tls-gd2
    TLS-GD2 126 105 6 6.8 Optional key release 4x Ø5.5 2 x M3 14 18 31 52 9 6.5 5 6.5 8 17 19 51 FLEXIBLE/ADJUSTABLE ACTUATOR 21 73 13 20 57 86 18 57 M5 x 4 25 31.5 18 14.5 4 52.5 60.5 67.5 3.5 STANDARD ACTUATOR 6.5 12 36 36 52 40 M5 CSK Adjusting screws 43 4
    Original PDF
    guardmaster
    Robust, A tongue operated interlocking with guard locking Guardmaster's newTLS-G D2 is a robust interlocking safety switch fo r Holds guard shut until machine is signalled safe guard locking. It is designed w ith a stainless steel actuator entry guide Holding force up to of 2000N
    OCR Scan PDF
    440g-mt
    Interlock Switches Guard Locking Switches 440G-MT Specifications Standards EN954-1, ISO13849-1, IEC/EN602041, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
    Original PDF
    tls-gd2
    Interlock Switches Guard Locking Switches TLS-GD2 Specifications Shown with optional Key Release Kit Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for
    Original PDF
    Interlock Switches G u a rd L ocking Switches T L
    Interlock Switches G u a rd L ocking Switches T L S-G D 2 ❁✝❂✩❃❅■✝❄✦❏✝❑❈❆✼▲✝❄❈❏ ❇ ❉ ❍ ❏ ❂✗●✮▼❃❅❏✑❊❋❉✝■ ❇ ❃❅❇ ❉ ❆✩●✣❍ Sp ecifica tions ❣✤❤ ✐✤❥✣❦✡✐✩❧✮❦✡♠
    Original PDF
    iec 60947-5-1
    Safety Relays Timing Control Units CU1 Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 per EN 954-1 (ISO13849-1) Approvals C-Tick, CE marked for all applicable directives, cULus & TÜV Power Supply
    Original PDF
    tls1-gd2
    Safeguarding Applications Guard Locking Interlocks TLS1-GD2, Bulletin 800, CU1, Bulletin 100, Dual Channel L1 L2 L3 24V AC/DC Fuse Start Momentary Push Button K1 K2 Lock Release Momentary Push Button Stop R2 R1 R3 Momentary CU1 Remote Push Button Indication Unit
    Original PDF
    Operator Interface Enabling Switches Overview ?
    Operator Interface Enabling Switches Overview ? Enabling devices are typically used when access to the hazardous portion of the machine is needed while the machine is running. Visual observations, minor adjustments, troubleshooting, calibration, tool changes, and lubrication are examples of tasks that may utilize
    Original PDF
    en954-1
    Interlock Switches Guard Locking Switches Centurion Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
    Original PDF
    (a) CU3 Description The CU3 has been designed to
    (a) CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor
    Original PDF