Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SUBSTATION Search Results

    SUBSTATION Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: KAM Primary Current Injection Test System • • • • • • • • A High current output up to 7000 A P P L I C A T I O N KAM test system is designed for primary injection testing of protection relays and circuit breakers, for commissioning and revamping of substations and electrical network.


    Original
    PDF

    8D16

    Contextual Info: BURNDY Substation TYPE NAS/NAH TERMINAL FOR COPPER CABLE High copper alloy reversible cap terminal for joining a wide range of cable to equipment pads. Tongue is side formed to provide adequate clearance and terminal is designed for one-wrench installation.


    Original
    nas29-nnas29-2nnah29-2nnas29-34n+7nas34-nnas34-2nnah34-2nnas34-34nnah34-34nnas40-2n8d16 PDF

    REB500

    Abstract: REC580 500PSM03 500SCM01 mvb bus schematics MVB Protocol converters SYS500 220V 5A Automatic Voltage Regulator GIS 110 kV 500BIM01
    Contextual Info: Bay control terminal REC 580*3.0 1MRK 511 059-BEN Page 1 Issued September 1999 Changed since October 1998 Data subject to change without notice REC580_1.tif Features The bay control terminal REC 580 is a numerical control device for the automation of complex high-voltage substations. It is a product in


    Original
    059-benrec580059-uen067-uen+10se-721reb500500psm03500scm01mvb bus schematicsmvb protocol converterssys500220v 5a automatic voltage regulatorgis 110 kv500bim01 PDF

    IEC61850

    Abstract: 60870-5-104 Eberle Relays RP570 REB500 60870-5-101 500CIM06 COM581 1MRB380084 eberle relay
    Contextual Info: Issued: June 2009 Substation Automation Products COM581 Communication gateway Introduction The communication gateway COM581 is used to link a substation automation system to a control system at a higher level and protection equipment to the substation automation system. The unit's modular design enables it to be configured to


    Original
    com581cap5811mrb520267-uen1mrb520184-uen+12ch-5400se-7211mrb520206-beniec6185060870-5-104eberle relaysrp570reb50060870-5-101500cim061mrb380084eberle relay PDF

    abb spaj RELAY

    Abstract: ABB rs-232 pin configuration SPAU SCS100 A03-8710E computer mouse circuit diagram scada POWER DISTRIBUTION DIAGRAM ABB SCIL SUBSTATION CONTROL SYSTEM
    Contextual Info: Type SCS 100 A8£A BROWN 80VÊRI Substation control system for distribution networks 1MDB11003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection SE 90625 Features Application •Control and supervision of medium voltage


    OCR Scan
    1mdb11003-enrs-2328710e1mdb11004-en+9abb spaj relayabb rs-232 pin configurationspauscs100a03-8710ecomputer mouse circuit diagramscada power distribution diagramabb scilsubstation control system PDF

    DKTFM1K405477

    Abstract: upfc DKTFM1K401057 DKTFM1K401178 DKTFM1K401568 DKTFM3K302277 DKTFM1K408607 DKTFM2K002857 DKTFM2K006127 DKTFM2K008167
    Contextual Info: TRAFIM Products Standard APPLICATIONS DC voltage filtering for: DC link Resonant filtering Active correction FACTS, UPFC, DVR. Speed converters (drives and traction) Windmills Substation PACKAGING Rectangular stainless steel case sandblasted. Grounding is


    Original
    400nh10kvrmsh-100h-210+10dktfm1k405477upfcdktfm1k401057dktfm1k401178dktfm1k401568dktfm3k302277dktfm1k408607dktfm2k002857dktfm2k006127dktfm2k008167 PDF

    Contextual Info: Delivering the renewable power of Wind Energy Unquestionable Reliability Designing and installing collection systems, including the 35kV cable portion, and the substations and transmission line work that accompany it, is one of the most critical aspects of a wind farm project. Typically cable is viewed as a commodity, with numerous reputable


    Original
    1-859-5tss-94-649 PDF

    Contextual Info: BURNDY Substation TYPE WASC-A-N CENTERFORMED WELDMENT TERMINAL Aluminum alloy weldment terminal. Type WASC-A-N has one contact surface on the center line of the tube. Holes are NEMA spaced for terminating aluminum or copper mating pads. PENETROX joint compound


    Original
    wasc14a2nwasc15a2nwasc15a34nwasc16a2n+6wasc16a34nwasc17a34nwasc18a2nwasc18a34nwasc18a44nwasc19a2n PDF

    upfc

    Abstract: Hotspot IEC61071 10kVrms 61373
    Contextual Info: TRAFIM, DC Filtering Capacitors APPLICATIONS DC voltage filtering for: DC link Resonant filtering Active correction FACTS, UPFC, DVR. Speed converters (drives and traction) Windmills Substation PACKAGING Rectangular stainless steel case sandblasted. Grounding is via a


    Original
    400nh10kvrms200nh430nh+4upfchotspotiec6107161373 PDF

    Contextual Info: BURNDY Substation TYPE B FLEXIBLE COPPER BRAID JUMPER CATALOG NUMBER BD12 BD12N* BD18 BD18N* BD24 BD24N* BE12 BE12N* BE18 BE18N* BE24 BE24N* BF12 BF12N* BF18 BF18N* BF24 BF24N* BG12 BG12N* BG18 BG18N* BG24 BG24N* B2D12 B2D12N* B2E12 B2E12N* B2F12


    Original
    bd12nbd18nbd24nbe12n+6be18nbe24nbf12nbf18nbf24nbg12n PDF

    TRAFIM Products

    Abstract: 1990 1142 trafim DKTFMXXXA3807 DKTFMXXXI1097 DKTFMXXXA9507 DKTFMXXXM0947 DKTFMXXXK0807 DKTFMXXXC1887
    Contextual Info: TRAFIM Products APPLICATIONS DC voltage filtering for: DC link Speed converter drives and traction Resonant filtering Active correction (FACTS) Windmills Substation PACKAGING Rectangular none magnetic stainless steel case. Grounding is via a nut on the top of the case.


    Original
    trafim products1990 1142trafimdktfmxxxa3807+5dktfmxxxi1097dktfmxxxa9507dktfmxxxm0947dktfmxxxk0807dktfmxxxc1887 PDF

    60255-21-1

    Abstract: CEI 60068214
    Contextual Info: Product data sheet Characteristics REL59808 substat., transfo.- A41A - Sepam series 10 Apr 3, 2013 Range of product Sepam series 10 Device short name A41A Relay application Substation Transformer Protection type Earth fault/standard earth fault 50N/51N Thermal overload protection 49RMS


    Original
    rel5980850n/51n49rms60255-21-1+1cei 60068214 PDF

    str - z 2156

    Abstract: STR 457 burndy connectors 18-23 S2GBP486A12B2 SWOH24A-5 SF3A44N866N WS90A ehps STR 456 m16 expansion bolt
    Contextual Info: BURNDY Substation — Welded/EHV TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M-3 Nomogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M-4 Gradient Calibrator . . . . . . . . . . . . . . . . . . . . . . . . . M-5


    Original
    swt-a-a-75sf3a44n8qsf3a44n866nstr - z 2156+8str 457burndy connectors 18-23s2gbp486a12b2swoh24a-5ws90aehpsstr 456m16 expansion bolt PDF

    ASEA generator manual

    Abstract: ASEA EG 20 ABB Air Circuit breaker 220 kv substation BROWN BOVERI Relay manual working of miniature circuit breaker MINIATURE CIRCUIT BREAKER Breaking capacity abb BROWN BOVERI DISTANCE RELAYS BROWN BOVERI protection relay BROWN BOVERI DIFFERENTIAL RELAYS
    Contextual Info: . Al li Hi 1% » » ASEA BROWN BOVERI ABB Relays Type RAAD B03-8210E S m a ll Sstation t 3 t i ^ n aautomatic n t n m a t ir Small Januar$ 5,0chang e ncœ S * New restoration equipment Abstract • Easy to install and program • Provides fast restoration at substation outages


    OCR Scan
    b03-8210858-300e858-500e858-100e+11s-72183asea generator manualasea eg 20abb air circuit breaker220 kv substationbrown boveri relay manualworking of miniature circuit breakerminiature circuit breaker breaking capacity abbbrown boveri distance relaysbrown boveri protection relaybrown boveri differential relays PDF

    Contextual Info: Trip circuit supervision relay Type RXTCS Station Automation & Protection ABB Substation Automation Products Features l l l l l l l l Continuous supervision of complete trip circuit independent of the circuit breaker position. Detects faults in the supervised circuits, such as


    Original
    003-ben001-ben1mdb10202 PDF

    nema 23

    Contextual Info: BURNDY Substation TYPE NAR-A TERMINAL FOR ALUMINUM AND COPPER CABLE TO FLAT Aluminum alloy terminal for joining a wide range of copper or aluminum cable to copper or aluminum pad. Properly proportioned to minimize conductor corrosion due to galvanic action. Drilling in pad conforms to NEMA


    Original
    nar25a-2nnar29a-2nnar29a-4nnar32a-2n+7nar32a-4nnar36a-2nnar36a-4nnar42a-2nnar42a-4nnar45a-2nnema 23 PDF

    E7512-0160

    Abstract: Raychem rdss raychem water immersion raychem instruction BCIC Raychem BPTM raychem epp bptm raychem raychem epp 0569 RDSS-CLIP-125
    Contextual Info: R Rayflate Duct Sealing System for Power Cables RDSS RDSS Rayflate Duct Sealing System for Power Cables Unsealed cable pipes and ducts need no longer cause dampness and flooding in substation basements, cable vaults and access manholes. In these environments rust, corrosion


    Original
    e7512-0160raychem rdssraychem water immersionraychem instruction+6bcicraychem bptmraychem eppbptm raychemraychem epp 0569rdss-clip-125 PDF

    power factor correction of substation

    Abstract: FPX86Y0505J FFVE6L0147KJ7 61373 FFVE6B0147K FFVE6K0227K upfc FFVE6L0107KJ7 FFVE6N0156KJ7 FFVE6N0246KJ7
    Contextual Info: TRAFIM, DC Filtering Capacitors APPLICATIONS DC voltage filtering for: DC link Resonant filtering Active correction FACTS, UPFC, DVR. Speed converters (drives and traction) Windmills Substation PACKAGING Rectangular stainless steel case sandblasted. Grounding is via a


    Original
    400nh10kvrmspower factor correction of substationfpx86y0505j+8ffve6l0147kj761373ffve6b0147kffve6k0227kupfcffve6l0107kj7ffve6n0156kj7ffve6n0246kj7 PDF

    1MKC950001-1

    Abstract: 8C27 SPA-ZC22 1mkc950001 abb razoa REL551 REL 551 1MKC9 REL 561 REL511
    Contextual Info: 6 r' SMS 010 - 1 MAK 511 014-BEN P"ne g 1 Substation Monitoring System PC DOS/MS WindowsTM based November 1995 Changed since March 1995 Replaces 1MRK501 0O2-BEN Dala subject lo change wilhoul nolice ABB Network Partner -settings and configuration of all parameters


    Original
    014-ben1mrk5011mkc950001-18c27+8spa-zc221mkc950001abb razoarel551rel 5511mkc9rel 561rel511 PDF

    SW04-15PHR470

    Abstract: SW04 WESTCODE SW16-24PHN380
    Contextual Info: Rectifier Diodes - Stud Types Product une of WISTCODi A n n i X Y S Com pany Westcode's rectifier devices are designed to survive even the most arduous of applications. These highly reliable components are suitable for all rectifier applications, including traction, industrial drives and substations. Voltages to 6kV and currents to 8kA.


    OCR Scan
    sw04-15phn3005phr300sw04-15hhn300+9sw04-15hhr300sw16-24phn320sw16-24phr320sw16-24hhn320sw16-24hhr320sw04-15phr470sw04westcodesw16-24phn380 PDF

    ABB MP200

    Abstract: DSCA 114 communication board ADLP80 abb DSDo 110 DSDI110A ADLP180 dsdi110 YC-560 MA220 RP570
    Contextual Info: «i mm A lp Type REC 200 Series iMDBiioii-lW Page 1 _Microprocessor based substation Âsêa b r o w n BovERi control and communication equipment SMS*changew^no««, *New ABB Network Control & Protection SE 890383 Features Application •Self-supervision


    OCR Scan
    b11011-00004-a1mdb00004-en3bse000+11570r0101abb mp200dsca 114 communication boardadlp80abb dsdo 110dsdi110aadlp180dsdi110yc-560ma220rp570 PDF

    ABB TOOLS COMBIFLEX

    Abstract: ABB Relays COMBIFLEX tools 1MRK514001-BEN REL511 current transformer ABB ABB power transformer ABB distributed control systems Distribution transformer abb transformer ABB panel and cubicles catalogue
    Contextual Info: Custom engineered protection and control systems 1MRK500 015-BEN Page 1 November 1995 Changed since March 1992 Replaces 1MDB00003-EN Data subject to change without notice ABB Network Partner Relays A broad range of protective relays for generators, substations and transmission/distribution


    OCR Scan
    1mrk500015-ben1mdb00003-en016-ben+12009-ben1mrk514001-ben002-benabb tools combiflexabb relays combiflex toolsrel511current transformer abbabb power transformerabb distributed control systemsdistribution transformer abbtransformer abbpanel and cubicles catalogue PDF

    ABB mp200

    Abstract: abb DSDo 110 microscada abb DSCA 114 communication board ADLP180 DSCA114 GI74 FW537 abb DSDi 110 QMV800
    Contextual Info: *M PIP Alili ABB Network Partner REC 200 Series 1MRK511 011-BEN Microprocessor based substation control and communication equipment Page 1 July 1997 Changed since November 1995 Data subject to change without notice 890383 Features 1Self-supervision ’ High availability


    OCR Scan
    1mrk511011-ben016-ben017-ben+10abb mp200abb dsdo 110microscada abbdsca 114 communication boardadlp180dsca114gi74fw537abb dsdi 110qmv800 PDF

    PA19355

    Abstract: ADVANCED COMMUNICATION DEVICES Silicon Power Corporation substation design
    Contextual Info: SSLTC Solid State Load Tap Changer Product Applications Reliable Environmentally Sensible Low Maintenance Silicon Power SSLTC™ successfully addresses the reliability and maintenance issues of legacy load-tap changers of substation transformers. Legacy load-tap changers utilize electro-mechanical technology that includes numerous


    Original
    pa19355advanced communication devicessilicon power corporationsubstation design PDF