SPACOM Search Results
Documents mentioning SPACOM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| spacom | 1 M D B 1 4 0 0 5 -E N Dimensions Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection Contents: COMBIFLEX COMBIFLEX/RL MODURES Series 900 SPACOM Page 1 7 7 9 12 COMBIFLEX Definition of the U and C modules: |
OCR Scan | ||||
| Version: 2.2-00 October 1999 Table of contents | Version: 2.2-00 October 1999 Table of contents Technical reference manual REB 551 1MRK 580 231-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 240-XEN Version 2.2-00 Service notes 2–5 1MRK 580 311-XEN Version 2.2-00 |
Original | ||||
| spau 330 | SPAU 330 C Overvoltage, undervoltage and residual voltage relay User´s manual and Technical description U > U < U 2 fn= 50Hz Un=100V / 110V (U ) 60Hz Un=100V / 110V (U0 ) Uo 5 IRF U 12 U 23 U 31 IRF IRF SPAU 330 C 18…80 V – n (U o >) n (U o >>) t /t >[ %] |
Original | ||||
| spam 150 | SPAM 150 C Motor protection relay User´s manual and Technical description 3I >> 3 2 (I ) I n = 1A 5A (I o ) I n = 1A 5A f n = 50Hz I 5 L1 I L2 I L3 I I o IRF 60Hz SPAM 150 C 80…265V – ~ 18…80V – NO NC I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %] |
Original | ||||
| spaj 160 | SPAJ 160 C Capacitor protection relay User´s manual and Technical description 3I > ∆I 3I < 2 I n = 1A I n = 1A f n = 50Hz 5A ( I ) 5A (∆I ) I 5 60Hz L1 I L2 I L3 ∆I c IRF SPAJ 160 C 80…265V – ~ 18…80V – RESET STEP I b >/I n U aux k SPCJ 4D40 |
Original | ||||
| reb 551 | A l l l i REB 551 * 1.2 Breaker protection terminal ■ , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner (SE950214) Features • Breaker related protection and associated func tions in a numerical unit |
OCR Scan | ||||
| substation control system | Type SCS 100 A8£A BROWN 80VÊRI Substation control system for distribution networks 1MDB11003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (SE 90625) Features Application •Control and supervision of medium voltage |
OCR Scan | ||||
| 1 User’s Guide contents 2 Introduction 3 | 1 User’s Guide contents 2 Introduction 3 Installation 4 General functions 5 Protection functions 6 Control functions 7 Monitoring functions 8 Index 9 Diagrams ABB Network Partner AB User’s Guide REC 561 Bay level control terminal 1MRK 511 009-UEN Version 1.0-00 |
Original | ||||
| rel 551 | ~ction pervision munication vith REL 551 * 1.2 1MRK Line differE~ntial protection OOS-BEN Page 1 terminal November 1997 Changed since October Data subject to change 1997 without nariGe ABB Network Partner (SE 95 02 13) Features .Phase segregateclline differential protection |
Original | ||||
| rel 511 | Version 2.2-00 October 1999 Table of contents Technical reference manual REL 511 1MRK 580 226-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 235-XEN Version 2.2-00 Service notes 2–5 1MRK 580 304-XEN Version 2.2-00 |
Original | ||||
| spaj | SPAJ 110 C Earth-fault relay User´s manual and Technical description B I 2 I n = 1A 5A ( I ) f n = 50Hz Io 5 60Hz IRF SPAJ 110 C STEP 80…265V – ~ 18…80V – U aux Io> In 0.35 STEP 0.1 0.8 SPCJ 1C8 0.5 REGISTERS 0 0 t > [ s] SG1 k 0.05 1 2 3 4 5 I o /I n |
Original | ||||
| rel 511 | REL 511 * 1.2 1 MR~ 506 002-BEN Line distance protection terminal ~ Page 1 November 1 7 Changed si October 1997 Dala subject Ichange wilhoul nolice ABB Network Partner (SE 95 02 08) - Features .Simultaneous measurement of the different phase-phase and ph ase-earth loop impedances |
Original | ||||
| Version 2.2-00 October 1999 Table of contents | Version 2.2-00 October 1999 Table of contents Technical reference manual REL 521 1MRK 580 227-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 236-XEN Version 2.2-00 Service notes 2–5 1MRK 580 312-XEN Version 2.2-00 |
Original | ||||
| SPAC 320 C Motor protection terminal User´s | SPAC 320 C Motor protection terminal User´s manual and Technical description O fn = 50 60 Hz I n= 1 I n= 1 / 5 A (I ) / 5 A (I o ) 3I >> 3 I 2 SPAC 320 C I IRF 5 L1 I L2 I L3 I I o IRF TEST INTERLOCK I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %] kc I s /I n |
Original | ||||
|
|
||||||
| sms 010 | 6 r' SMS 010 - 1 MAK 511 014-BEN P"ne g 1 Substation Monitoring System (PC DOS/MS WindowsTM based) November 1995 Changed since March 1995 Replaces 1MRK501 0O2-BEN Dala subject lo change wilhoul nolice ABB Network Partner -settings and configuration of all parameters |
Original | ||||
| SPAC 335 C and SPAC 336 C Feeder terminals User´s | SPAC 335 C and SPAC 336 C Feeder terminals User´s manual and Technical description B O fn = 50 60 Hz I n= 1 I n= 1 U n = 100 / 5 / 5 / 110 A( I ) A( I o ) V(U o ) 2I > I I 2 SPAC 335 C I IRF 5 L1 I L3 U o I o IRF TEST INTERLOCK I >/I n GAS PRESSURE STEP MOTOR VOLTAGE |
Original | ||||
| rel 521 | REL 521 * 1.2 Line distance protection 1 MAK 506 003-BEN terminal Page 1…\..- ..~.a'..~. .~~, Changed since Oclober 1997 Data subject lo change wilhoul nolice ABB Network Partner (SEgS 02 16) ~ Features .Simultaneous measurement of the phasephase and ph ase-earth loop impedances within |
Original | ||||
| rel 561 | - REL 561 * 1.2 Line differential 1MRK 506 006-BEN Pan" 1 November 1997 Changed since October 1997 Dala subjecI lo change without nolice protec:tion terminal ABB Network Partner (SE 95 02 12) Features .Phase segregated line differential protection .Current differential measurement evaluating |
Original | ||||
| «i mm A lp Type REC 200 Series iMDBiioii-lW Page | «i mm A lp Type REC 200 Series iMDBiioii-lW Page 1 _______Microprocessor based substation Âsêa b r o w n BovERi control and communication equipment SMS*changew^no««, *New ABB Network Control & Protection SE 890383 Features Application •Self-supervision |
OCR Scan | ||||
| 1mrk511 | *M PIP Alili ABB Network Partner REC 200 Series 1MRK511 011-BEN Microprocessor based substation control and communication equipment Page 1 July 1997 Changed since November 1995 Data subject to change without notice (890383) Features 1Self-supervision ’ High availability |
OCR Scan | ||||
| sms 010 | “ *7 Type SMS 010 * Station Monitoring System —— t - — rr~ 1MDB11019-EN Page 1 September 1993 Data subject to change without notice • New ABB Network Control & Protection Features Application • Provides on-request information from pro* tective relays comprising |
OCR Scan | ||||
| REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance | REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance protection terminal ~ Page 1 November 199 Changed since Data subject lo ctober 1997 ange wilhout nolice ABB Network Partner (SE950207) Features .Simultaneous measurement of the different phase-phase loop impedances within the |
Original | ||||
| 8c27 | SPCR 8C27 Disturbance recorder User´s manual and Technical description IRF STEP RESET 0035A TRIGGED / READY SPCR 8C27 1MRS 750511-MUM EN Issued 96-12-02 Version A (replaces 34 SPCR 2 EN1) Checked L-W U Approved TK SPCR 8C27 Disturbance recorder Data subject to change without notice |
Original | ||||
| SPAC 330 C and SPAC 331 C Feeder terminals User´s | SPAC 330 C and SPAC 331 C Feeder terminals User´s manual and Technical description B O fn = 50 60 Hz I n= 1 I n= 1 U n = 100 / 5 / 5 / 110 A( I ) A( I o ) V(U o ) 2I > I I 2 SPAC 330 C I IRF 5 L1 I L3 U o I o IRF TEST INTERLOCK I >/I n GAS PRESSURE STEP MOTOR VOLTAGE |
Original | ||||
| SPAA 120 C and SPAA 121 C Feeder protection relay | SPAA 120 C and SPAA 121 C Feeder protection relay User´s manual and Technical description B I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) f n = 50Hz 60Hz 2I > I 2 I 5 L1 I L3 U o I o IRF SPAA 120 C 80…265V – ~ 18…80V – I >/I n U aux |
Original | ||||