Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SPACOM Search Results

    Documents mentioning SPACOM

    Document Partial File Text Tags Type PDF
    spacom
    1 M D B 1 4 0 0 5 -E N Dimensions Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection Contents: COMBIFLEX COMBIFLEX/RL MODURES Series 900 SPACOM Page 1 7 7 9 12 COMBIFLEX Definition of the U and C modules:
    OCR Scan PDF
    Version: 2.2-00 October 1999 Table of contents
    Version: 2.2-00 October 1999 Table of contents Technical reference manual REB 551 1MRK 580 231-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 240-XEN Version 2.2-00 Service notes 2–5 1MRK 580 311-XEN Version 2.2-00
    Original PDF
    spau 330
    SPAU 330 C Overvoltage, undervoltage and residual voltage relay User´s manual and Technical description U > U < U 2 fn= 50Hz Un=100V / 110V (U ) 60Hz Un=100V / 110V (U0 ) Uo 5 IRF U 12 U 23 U 31 IRF IRF SPAU 330 C 18…80 V – n (U o >) n (U o >>) t /t >[ %]
    Original PDF
    spam 150
    SPAM 150 C Motor protection relay User´s manual and Technical description 3I >> 3 2 (I ) I n = 1A 5A (I o ) I n = 1A 5A f n = 50Hz I 5 L1 I L2 I L3 I I o IRF 60Hz SPAM 150 C 80…265V – ~ 18…80V – NO NC I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %]
    Original PDF
    spaj 160
    SPAJ 160 C Capacitor protection relay User´s manual and Technical description 3I > ∆I 3I < 2 I n = 1A I n = 1A f n = 50Hz 5A ( I ) 5A (∆I ) I 5 60Hz L1 I L2 I L3 ∆I c IRF SPAJ 160 C 80…265V – ~ 18…80V – RESET STEP I b >/I n U aux k SPCJ 4D40
    Original PDF
    reb 551
    A l l l i REB 551 * 1.2 Breaker protection terminal ■ , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner (SE950214) Features • Breaker related protection and associated func­ tions in a numerical unit
    OCR Scan PDF
    substation control system
    Type SCS 100 A8£A BROWN 80VÊRI Substation control system for distribution networks 1MDB11003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (SE 90625) Features Application •Control and supervision of medium voltage
    OCR Scan PDF
    1 User’s Guide contents 2 Introduction 3
    1 User’s Guide contents 2 Introduction 3 Installation 4 General functions 5 Protection functions 6 Control functions 7 Monitoring functions 8 Index 9 Diagrams ABB Network Partner AB User’s Guide REC 561 Bay level control terminal 1MRK 511 009-UEN Version 1.0-00
    Original PDF
    rel 551
    ~ction pervision munication vith REL 551 * 1.2 1MRK Line differE~ntial protection OOS-BEN Page 1 terminal November 1997 Changed since October Data subject to change 1997 without nariGe ABB Network Partner (SE 95 02 13) Features .Phase segregateclline differential protection
    Original PDF
    rel 511
    Version 2.2-00 October 1999 Table of contents Technical reference manual REL 511 1MRK 580 226-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 235-XEN Version 2.2-00 Service notes 2–5 1MRK 580 304-XEN Version 2.2-00
    Original PDF
    spaj
    SPAJ 110 C Earth-fault relay User´s manual and Technical description B I 2 I n = 1A 5A ( I ) f n = 50Hz Io 5 60Hz IRF SPAJ 110 C STEP 80…265V – ~ 18…80V – U aux Io> In 0.35 STEP 0.1 0.8 SPCJ 1C8 0.5 REGISTERS 0 0 t > [ s] SG1 k 0.05 1 2 3 4 5 I o /I n
    Original PDF
    rel 511
    REL 511 * 1.2 1 MR~ 506 002-BEN Line distance protection terminal ~ Page 1 November 1 7 Changed si October 1997 Dala subject Ichange wilhoul nolice ABB Network Partner (SE 95 02 08) - Features .Simultaneous measurement of the different phase-phase and ph ase-earth loop impedances
    Original PDF
    Version 2.2-00 October 1999 Table of contents
    Version 2.2-00 October 1999 Table of contents Technical reference manual REL 521 1MRK 580 227-XEN Page 1 – 1 Section Name of document Page Document number 2 Revisions 2–3 1MRK 580 236-XEN Version 2.2-00 Service notes 2–5 1MRK 580 312-XEN Version 2.2-00
    Original PDF
    SPAC 320 C Motor protection terminal User´s
    SPAC 320 C Motor protection terminal User´s manual and Technical description O fn = 50 60 Hz I n= 1 I n= 1 / 5 A (I ) / 5 A (I o ) 3I >> 3 I 2 SPAC 320 C I IRF 5 L1 I L2 I L3 I I o IRF TEST INTERLOCK I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %] kc I s /I n
    Original PDF
    sms 010
    6 r' SMS 010 - 1 MAK 511 014-BEN P"ne g 1 Substation Monitoring System (PC DOS/MS WindowsTM based) November 1995 Changed since March 1995 Replaces 1MRK501 0O2-BEN Dala subject lo change wilhoul nolice ABB Network Partner -settings and configuration of all parameters
    Original PDF
    SPAC 335 C and SPAC 336 C Feeder terminals User´s
    SPAC 335 C and SPAC 336 C Feeder terminals User´s manual and Technical description B O fn = 50 60 Hz I n= 1 I n= 1 U n = 100 / 5 / 5 / 110 A( I ) A( I o ) V(U o ) 2I > I I 2 SPAC 335 C I IRF 5 L1 I L3 U o I o IRF TEST INTERLOCK I >/I n GAS PRESSURE STEP MOTOR VOLTAGE
    Original PDF
    rel 521
    REL 521 * 1.2 Line distance protection 1 MAK 506 003-BEN terminal Page 1…\..- ..~.a'..~. .~~, Changed since Oclober 1997 Data subject lo change wilhoul nolice ABB Network Partner (SEgS 02 16) ~ Features .Simultaneous measurement of the phasephase and ph ase-earth loop impedances within
    Original PDF
    rel 561
    - REL 561 * 1.2 Line differential 1MRK 506 006-BEN Pan" 1 November 1997 Changed since October 1997 Dala subjecI lo change without nolice protec:tion terminal ABB Network Partner (SE 95 02 12) Features .Phase segregated line differential protection .Current differential measurement evaluating
    Original PDF
    «i mm A lp Type REC 200 Series iMDBiioii-lW Page
    «i mm A lp Type REC 200 Series iMDBiioii-lW Page 1 _______Microprocessor based substation Âsêa b r o w n BovERi control and communication equipment SMS*changew^no««, *New ABB Network Control & Protection SE 890383 Features Application •Self-supervision
    OCR Scan PDF
    1mrk511
    *M PIP Alili ABB Network Partner REC 200 Series 1MRK511 011-BEN Microprocessor based substation control and communication equipment Page 1 July 1997 Changed since November 1995 Data subject to change without notice (890383) Features 1Self-supervision ’ High availability
    OCR Scan PDF
    sms 010
    “ *7 Type SMS 010 * Station Monitoring System —— t - — rr~ 1MDB11019-EN Page 1 September 1993 Data subject to change without notice • New ABB Network Control & Protection Features Application • Provides on-request information from pro* tective relays comprising
    OCR Scan PDF
    REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance
    REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance protection terminal ~ Page 1 November 199 Changed since Data subject lo ctober 1997 ange wilhout nolice ABB Network Partner (SE950207) Features .Simultaneous measurement of the different phase-phase loop impedances within the
    Original PDF
    8c27
    SPCR 8C27 Disturbance recorder User´s manual and Technical description IRF STEP RESET 0035A TRIGGED / READY SPCR 8C27 1MRS 750511-MUM EN Issued 96-12-02 Version A (replaces 34 SPCR 2 EN1) Checked L-W U Approved TK SPCR 8C27 Disturbance recorder Data subject to change without notice
    Original PDF
    SPAC 330 C and SPAC 331 C Feeder terminals User´s
    SPAC 330 C and SPAC 331 C Feeder terminals User´s manual and Technical description B O fn = 50 60 Hz I n= 1 I n= 1 U n = 100 / 5 / 5 / 110 A( I ) A( I o ) V(U o ) 2I > I I 2 SPAC 330 C I IRF 5 L1 I L3 U o I o IRF TEST INTERLOCK I >/I n GAS PRESSURE STEP MOTOR VOLTAGE
    Original PDF
    SPAA 120 C and SPAA 121 C Feeder protection relay
    SPAA 120 C and SPAA 121 C Feeder protection relay User´s manual and Technical description B I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) f n = 50Hz 60Hz 2I > I 2 I 5 L1 I L3 U o I o IRF SPAA 120 C 80…265V – ~ 18…80V – I >/I n U aux
    Original PDF