    directional relay type rxpe 4
    Catalogue RK 51-10 E JK S E A e d itio n 2 Jan ua ry 1976 Directional relay type RXPE 4 .y. f I: I I: ! . ■: >(./.ts L t ~~ f Í" D irectional relay RXPE 4 operates accurately, dow n to 0.1 5% o f the rated voltage is provided with nine d iffe re n t curre nt
    OCR Scan PDF
    asea brown
    ~ ~, j~ ASEA BROWN BOVERI Selec1tion Guide AB8 Relays Motor protection ILow Reverse power reley (RXPE 40) BO3-3020E Under-frequency reley RXFE 4 B03-2910E Yes No jYes Differential relay RADHA BO3-6011E ,Yes Differential relay RADHA BO3.6011E Temperature monitoring system
    Original PDF
    reverse power relay
    ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current
    OCR Scan PDF
    rxpe 40
    ABB ASEA BROWN BOVERI Type RXPE 40 0° directional overcurrent relay — B03-3013 if * ' Page 1 January 1989 Changed since January 1987 Data subiect to change without notice ABB Relays Abstract Application • Voltage-polarized • Angle of maximum sensitivity:
    OCR Scan PDF
    rxpe
    il lili J ^ k lP IP Directional earth-fault relay and protection RXPE 47 1MRK 509 030-BEN Page 1 Issued June 1999 Changed since July 1998 Replaces part of 1MRK 509 030-BEN Data subject to change without notice Features Application Directional earth-fault relay
    OCR Scan PDF
    rxpe
    Il Hi II **I»IP ASEA B R O W N BOVERI ABB Relays Abstract Application RXPE 47 +65° directional-overcurrent relay B03-3012E Page 1 June 30, 1982 Data subject to change without notice • Voltage-polarized • Operating value constant within a wide polarizing voltage range
    OCR Scan PDF
    overcurrent relay
    A llli Type RXPE 41/40 W W W -9 0 ° or 0° directional overcurrent relay ASEA B R O W N BO V ER I w w w " w w w m w B03-3010 p ìe ! 1 J une 3 0. 1982 D a ta s ubject to c h a n g e without notice « ABB Relays o Abstract Voltage-polarized Angle of maximum sensitivity:
    OCR Scan PDF
    ragpc
    Gil» Mil» ASEA BROWN BOVERI ABB Relays Abstract Application Design Type RAGPC B03-4013E Loss-of-excitation relay for . , synchronous generators Changed since January 1985 Data subject to change without notice » ■ • Alarm for underexcitation and trip for lossof-excitation
    OCR Scan PDF
    m. »11 MMV
    m. »11 MMV ______________________________________________________________________________ Selection guide B03-0240E Generator protection ABB Relays Data subject to change without notice Turbo generators < 5 MVA air-cooled 5 - 8 0 MVA air-cooled 8 0 -1 5 0 MVA
    OCR Scan PDF
    INFORMATION RF 640 02IE 1# HL, Nov. 1988 Edition
    INFORMATION RF 640 02IE 1# HL, Nov. 1988 Edition 1 Out-of-step relay for synchronous machines Out-of-step operation means that the machine with intact field is running out of synchronism with the network. During the out-of-step condition, the machine current varies heavily as the rotor (machine
    OCR Scan PDF
    A » 1 1 » ■ I V 1NFORM Al'loH FiF U 0 021E TIL,
    A » 1 1 » ■ I V 1NFORM Al'loH FiF U 0 021E TIL, tiOVH Edition 1 n u t - o f - s t o p r e l ay t o r tiv n ^ h ionous machine--; Q u t - o f - s t e p o ^ r a t i o n m e a u that. t-he m a c h in e w i t h i n t a c t f i e l d i s tunuir.q out o f s y n c h r o n i s m wj lh t h e
    OCR Scan PDF
    raepa
    ik 111» n i i p RAEPA 1MRK 506 018-BEN Page 1 February 1997 Changed since January 1989 D ata subject to c hange without notice Directional earth-fault protection ABB Network Partner Features >Used for time delayed back-up and pilot applica­ tions on solidly earthed systems
    OCR Scan PDF
    A SEA Catalogue RK 65-20 E Edition 1 Directional
    A SEA Catalogue RK 65-20 E Edition 1 Directional protective relays A ugust 1976 File R, Part 1 C lO lM f B T l 1F IL 1 E IX P • Used, among other things, in shortcircu it protection and earth-fault pro­ tection for cables and overhead lines, in out-of-step protection fo r
    OCR Scan PDF
    A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay
    OCR Scan PDF
    brown boveri
    ,A BROWN BOVERI ABB Relays SelecticJn guide Page 1 January 1985 Changed since June 1982 Data subject to change without notice Direction,al relays For complete teChnical data see BO3-3003E Application? Ground-fault protection Phase-fault directional overcurrent
    Original PDF
    rxke 1
    Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays
    OCR Scan PDF
    ASEA RELAYS INFORMATION RF 64 0-0 11 RFA, January
    ASEA RELAYS INFORMATION RF 64 0-0 11 RFA, January 1986 Edition 3 1 O ut-of-step relay for synchronous generators and motors G ENERAL Out- of- st ep operation means that, the machine with in ta c t field is running out of synchronism with the network. During the outof-step condition, the machine current varies heavily as the
    OCR Scan PDF
    raepa
    ; k l l l l Type RAEPA m p ip + 70° directional ground- ASEA B R O W N BO VERI ^ g^ bos-mso* Changed since January 1987 Data subiect t0 change without notice |g y ABB Relays Abstract Application • Used for time delayed back-up and pilot applications on solidly grounded systems
    OCR Scan PDF
    rf3000
    RF3000 SPREAD-SPECTRUM BASEBAND MODEM Typical Applications • IEEE802.11b Wireless LAN Systems • Wireless Modems • ISM Band Systems • Wireless Point-to-Point • Direct Sequence Systems Product Description The RF3000 is a monolithic CMOS baseband processor.
    Original PDF
    ragpc
    J L li I I 1 lrlc"Nn RX 641-303 E INFORMATION iS E i BRO W N BCVERI F r o m /B a te <*09- RER, August 1973 ABB Refays E ditio n l F>age 7452 m * rk X' 00-90 Section 6 Loss-of-field relays type BAGPA and RAGPC for synchronous generators _____________ ______________________________
    OCR Scan PDF
    raepa
    i4ii8 v Type RAEPA 1MDB06020-EN + 70° directional earth fault relay0 m2* i*» Data subject to change without notice • New  £ì«-;v . i ¿CVS» i't ABB Network Control & Protection Features Application »Used for time delayed back-up and pilot applications on solidly earthed systems
    OCR Scan PDF
    4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û
    4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û a tB R F R , December 19S3 ABB Refays IjîFû'Nd. RK 511-300 E fie g . P ag« 5625 1 Edition i Directional relay type R X PE k o Single phase directional current relay using voltage reference o Different current ranges available for operate values from 3 nriA
    OCR Scan PDF
    information RK 611-300 E E d itio n 2 F e b ru a
    information RK 611-300 E E d itio n 2 F e b ru a ry 19?6 F ile Relay Division /?/CSS Ea r t h - f a u l t pro tective relays w ith RK 00-90 E O fT Section 6 C?w<£\ - /3 o pen - core CURRENT TRANSFORMERS in non-solidly earthed networks without current convertors
    OCR Scan PDF
    raepa
    ASEA Catalogue RK 65-53 E Edition 1 Directional earth-fault relay type RAEPA for solidly earthed networks • high sensitivity, even at polarising voltages down to 0.5 % of rated voltage • built-in filter for suppressing har­ monics • static directional current relay requir­
    OCR Scan PDF
    brown boveri
    ABB ASEA BROWN BOVERI B03-3003E Directional relay data table Page 1 January 1987 Changed since May 1983 Data subject to change without notic» ABB Relays Current and voltage operate values for different values of cp. u/u„% The curve is valid for all settings.
    OCR Scan PDF