    A S E A C atalog u e RK 61 -15 E Edition 1 S
    A S E A C atalog u e RK 61 -15 E Edition 1 S eptem ber 1981 File R, Part 1 Feeder protection type RACIB The RACIB feed er protection is intended prim arily fo r use in radial-supplied pow er distribution networks. The pro tection c o n ta in s : • A three-phase tim a^overcurrent relay w ith starting,
    OCR Scan PDF
    brown boveri
    Ak liil M llll ASEA BROWN BOVERI ABB Relays Abstract Application Design _ Type RARIC * . Shaft-current relay B03-4016E S uea!vi987 Changed since January 1985 Data subject to change without notice • Sensitive bearing protection for large ma­ chines, detects ac 0.25—0.8 A shaft cur­
    OCR Scan PDF
    Catalogue RK 85-18 E ASEA Edition 1 A p ril 1978
    Catalogue RK 85-18 E ASEA Edition 1 A p ril 1978 Reclosing relay type RAABA For lines with delayed overcurrent protection Two-shot reclosing • Intended to be used together with delayed ove: cu rre n t relay with a sta?:~ ing co n ta ci which gives the starting
    OCR Scan PDF
    011-ben
    il II II A D V R X EG 21 and R A EG 1MRK 509 011-BEN Voltage relay and protection assemblies February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (S E 9 4 07 13) Features • Single- and three-phase versions for over- or
    OCR Scan PDF
    Type RAEUB ASEA BROWN 80VERI Earth fault
    Type RAEUB ASEA BROWN 80VERI Earth fault protection for power rectifiers •r**1FH ?»W" 1M bB0901^ -£ N Page 1 August 1990 Data subject to change without notice ABB Network Control & Protection (802343) Features Application • Provides earth fault protection on systems
    OCR Scan PDF
    distance relay
    A S E A Catalogue RK 61-25 E Edition 1 1961-01 R e R, part 1 Distance relay, type RAZOG * Three-ptiase switched-scheme static relay suitable for pro­ tecting overhead lines and cabies In high voltage networks. • Easy to change the settings for possible future modifica­
    OCR Scan PDF
    radsb
    Catalogue RK 62-12 E Edition 2 1981-09 File R, part 1 T ransformer differential relay type RADSB The RADSB is a three-phase percentage differential relay with two, three or five through-fag[[ restraint inputs. The relay can b& used for the protection of duel-win ding or multi-windIng transformers which are provided with one or more circuitbreakers for each winding. TTie relay is available in different
    OCR Scan PDF
    A SEA Catalogue RK 65-20 E Edition 1 Directional
    A SEA Catalogue RK 65-20 E Edition 1 Directional protective relays A ugust 1976 File R, Part 1 C lO lM f B T l 1F IL 1 E IX P • Used, among other things, in shortcircu it protection and earth-fault pro­ tection for cables and overhead lines, in out-of-step protection fo r
    OCR Scan PDF
    C I oIP bSS Catalogue RK 28-11 E Edition 1,
    C I oIP bSS Catalogue RK 28-11 E Edition 1, January 1973 File R, Part 1 ABB Relays Signal systems type RSF1 with flags [c1o |m |bUS [T 1f |L| [ x f Function modules and function units • Built up of standardised function mo­ dules and function units com prising
    OCR Scan PDF
    Negative sequence overcurrent relay and
    Negative sequence overcurrent relay and protection assemblies RXIIK 4 and RAIIK 400 1MRK 509 045-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980088) Features RXIIK 4 relay • Negative sequence overcurrent relays are
    Original PDF
    b03-1003e
    J% |P IP IP SB s ASEA BRO W N B O VERl ABB Relays Auxiliary relay datatable data V4W41V* bo3- ioo3 e Kryi«» Changed since January 1987 Data subject to change without notic ABB Relays Auxiliary relay data table B03-1003E Page 2 Light-duty single contacts
    OCR Scan PDF
    Catalogue RK 85-17 E ASEA Edition 1 April 1978
    Catalogue RK 85-17 E ASEA Edition 1 April 1978 Rie R Part 1 Reclosing relay type RAAAC For line^ wsth delayed overemfent protection Single-shut reclosing Intended to be used together with delayed overcurrent relay with or without starting contact. The starting
    OCR Scan PDF
    razoa
    ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se­ quential measurement distance relay for overhead lines and cables • Independent X and R reach settings
    OCR Scan PDF
    Catalogue RK 65-17 E Edition 2 A p r ili 961 File
    Catalogue RK 65-17 E Edition 2 A p r ili 961 File R, Part 1 ■ Time-overcurrent protective relays • Used as short-circuit and earth-fault re lays for cables, power lines, machines and transformers • independent or inverse time-iag characteristic • One, two and three phase protection with separale m eas­
    OCR Scan PDF
    relay
    Catalogue RK 65-12 E ASEA E d itio n 1 Ju n e 1975 File F¡, Part 1 Three-phase delayed overcurrent protective relays Used m ainly as a s h o rt-c irc u it pro te c­ tio n fo r cables and overhead lines. S tatic or electrom echanical relay units. curre nt
    OCR Scan PDF
    Al lili Mil» asea b r o w n bo veri ABB Relays
    Al lili Mil» asea b r o w n bo veri ABB Relays --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
    OCR Scan PDF
    rxpe 4
    JF\MPIP ______________________ ■…• __________ aseabrownboveri Directional overcurrent and B03-3020 ABB Relays Abstract Application ground-fault relay assemblies (RXPE 42, 47 and RXPF 4) <Two-phase or three-phase directional over­ current protection for cables and overhead
    OCR Scan PDF
    1^ I® ASEA BRO W N BOVERI Type R A D S B
    1^ I® ASEA BRO W N BOVERI Type R A D S B bo3-soi2e Transformer differential SSbsR. w r e la y Data subject to change without notic m? ABB Relays (840536) Abstract Application • Complete phase and ground protection • Static measuring circuits with active filters
    OCR Scan PDF
    Catalogue RK 21-10 E Edition 2 December 1974 File
    Catalogue RK 21-10 E Edition 2 December 1974 File R, Part 1 Auxiliary relays Suitable far tripping, blocking, centre zero relays etc. in protective relay systems and In automatic industrial systems With high voltage insulation. Content* Screen protected and dusi-prool vvilht a
    OCR Scan PDF
    rakzb
    All II Ml»» RAKZB Impedance protection relay 1MRK 509 014-BEN Page 1 February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (SE 83 02 44) Features • Single and two zone versions • Circular or modified lens characteristics with
    OCR Scan PDF
    Jnta-No. INFORMATION EX 642-300 E RFR, November
    Jnta-No. INFORMATION EX 642-300 E RFR, November 1981 Edition 3 7453 froiW D fiW Fieg, Page 1 Motor Protection Type RAMPA List of contents Section Title Page 1 2 3 4 5 6 GENERAL INPUT CIRCUITRY OVERLOAD RELAY OVERCURRENT RELAY EAH.TH-MULT RELAY NEGATIVE SEQUENCE RELAY
    OCR Scan PDF
    rxpe
    il lili J ^ k lP IP Directional earth-fault relay and protection RXPE 47 1MRK 509 030-BEN Page 1 Issued June 1999 Changed since July 1998 Replaces part of 1MRK 509 030-BEN Data subject to change without notice Features Application Directional earth-fault relay
    OCR Scan PDF
    raepa
    ASEA Catalogue RK 65-53 E Edition 1 Directional earth-fault relay type RAEPA for solidly earthed networks • high sensitivity, even at polarising voltages down to 0.5 % of rated voltage • built-in filter for suppressing har­ monics • static directional current relay requir­
    OCR Scan PDF
    029-ben
    A m n i i i p RXPF 1MRK 509 029-BEN Directional earth-fault relay and protection Page 1 April 1997 Changed since November 1995 t0 Change without notice _ _. - Datasub)0Ct ABB Network Partner (850014) Features Application RXPF 4 • Directional earth fault relay for isolated or high
    OCR Scan PDF
    rakzb
    là I I I I U U E R A bE A B R O W N BUVfcHI Type RAKZB B03-3213E Three-phase impedance f© | 3 y 0313 SUb*eCt 10 chan9e wi,ho‘ ABB Relays (8 3 0 2 4 3 Abstract Application • One and two zone versions • Offset circular MHO or modified lens char­ acteristic, 60° or 75°
    OCR Scan PDF