    76745-1CU-20LF
    Amphenol Communications Solutions BergStik®, Board to Board connector, Unshrouded vertical stacked header, Through Hole, Double Row, 20 Positions, 2.54mm (0.100in) Pitch. PDF
    76745-113-22LF
    Amphenol Communications Solutions BergStik®, Board to Board connector, Unshrouded vertical stacked header, Through Hole, Double Row, 22 Positions, 2.54mm (0.100in) Pitch. PDF
    76745-1CH-10LF
    Amphenol Communications Solutions BergStik®, Board to Board connector, Unshrouded vertical stacked header, Through Hole, Double Row, 10 Positions, 2.54mm (0.100in) Pitch. PDF
    76745-1DXV16LF
    Amphenol Communications Solutions BergStik®, Board to Board connector, Unshrouded vertical stacked header, Through Hole, Double Row, 16 Positions, 2.54mm (0.100in) Pitch. PDF
    76745-121-14LF
    Amphenol Communications Solutions BergStik®, Board to Board connector, Unshrouded vertical stacked header, Through Hole, Double Row, 14 Positions, 2.54mm (0.100in) Pitch. PDF

    Documents mentioning RADSS 7451

    Document Partial File Text Tags Type PDF
    radss
    Busbar protection with auxiliary summation CT’s RADSS 1-phase 1MRK 505 009-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980086) Features • Percentage restrained bus differential relay for phase and earth faults
    Original PDF
    radss
    Busbar differential protection RADSS 3-phase 1MRK 505 008-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE 81 02 58) (SE 81 02 60) Features • Percentage restrained bus differential relay for phase and earth faults
    Original PDF
    radss
    ABB Type RAICC ASEA BROW N BOVERI Breaker-failure relay (BFR) (for use with RADSS busbar ABB Relays Pro,ectio"> Abstract “ 3"611 D ata subject to c h a n g e without notici • Enables a total fault clearance time of less than 150 ms • Not affected by line CT-saturation
    OCR Scan PDF
    radss
    in(o-No. INFORMATION From/Date R FF, O ctober 1975 ASEA RELAYS RF 637 131 E Reg. 7451 Page 1 Sim plified Breaker Failure Schem e with RADSS Bus D iff P ro tectio n Introduction When a line c irc u it-b re a k e r fails to open in th e case of a line fa u lt, it has becom e general p ra c tic e to trip all th e ad jac e n t
    OCR Scan PDF
    radss
    A M l i l l l l Information ASEA BR O W N BO VERI RFA August 1980 ABB Relays E nclosure drwg. 7451 298-H A RF 637 321 <=. S -I.si o ¿ o-o« ï 'Hœ"-: S »5 c3 ~í»^5 e:o 00 wt RADSS 1 Zone, 12 Lines, 3-phase C ir c u it D iagram 7451 298-HA Modified ty p ic a l se ttin g s
    OCR Scan PDF
    breaker failure relay
    41 » 1 ! M l » ASEA BROW N BOVERl INFORMATION FHS May 1989 RF 637 375E 1. Type RAICC Breaker Failure Relay (BFR) Introduction The RQDT 040 plug-in unit is a simple, but very effective and versatile, 3-phase current decting element incor­ porated in a new BFR-scheme. It can be used with ease in
    OCR Scan PDF
    sx91
    T y p e s R A ÏC A , R A IG O a n d S X Breaker-failure protection 91 05005 im d b -e n Page 1 »¡*1992 Changed since August 1990 \ Data subject to change without notice ABB Network Control & Protection RAÏCA (822618) (870992) RAICC SX91 (228957) Features