Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RADIATION IONIZING D Search Results

    RADIATION IONIZING D Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DEO2V2P500M40LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 2V2 Pin Right Angle Solder 40A, Europe Standard, 200 Cycles, Front: Threaded Insert UNC 4.40, Back: Metal Brackets. PDF
    DE2V2P543G30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 2V2 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Without Accessory, Back: Harpoons for 1.6mm PCB Thickness. PDF
    DAL3W3P543M30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Threaded Insert M3, Back: Metal Brackets. PDF
    DAV3W3P500A30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 200 Cycles, Front: Female Screw Lock UNC 4.40, Back: Without Accessory on PCB. PDF
    DAO3W3P543A30LF
    Amphenol Communications Solutions D-Sub Power Board Mount Connectors, Input Output Connectors, Full Power 3W3 Pin Right Angle Solder 30A, Europe Standard, 500 Cycles, Front: Threaded Insert UNC 4.40, Back: Without Accessory on PCB. PDF

    Documents mentioning RADIATION IONIZING D

    Document Partial File Text Tags Type PDF
    QPRO XQR4000XL QML Radiation Hardened Field
    QPRO XQR4000XL QML Radiation Hardened Field Programmable Gate Arrays KXILINX Septem ber 28, 1998 Prelim inary Product S pecification XQR4000XL Series Features • - Radiation H ardened FPGAs for space and satellite applications G uaranteed Total Ionizing Dose
    OCR Scan PDF
    hsn-3000
    MAXWELL LABS IN C / S-CUBED 37E D 507=1721 HMnaauL 0000042 1 SCUB - 65-13 S-CUBED Division RADIATION HARDENED HYBRID NUCLEAR EVENT DETECTOR Model HSN-3000 FEATURES • Detects ionizing radiation pulses • 100% tested/certified detection threshold level • Adjustable circumvention period
    OCR Scan PDF
    mil-std-883
    Comprehensive radiation effects test and support MIL-STD Radiation Effects Test Services n Total Ionizing Dose (TID) RLAT (50 to 300 rads/sec) – MIL-STD-883 TM 1019, Cond. A n TID ELDRS (10 to 100 mrads/sec) – MIL-STD-883 TM 1019, Cond. D, ESA/SCC22900
    Original PDF
    MAXWELL LABS IN C / S-CUBED 37E D 507=1751
    MAXWELL LABS IN C / S-CUBED 37E D 507=1751 Q0Q0G4Q S H S C U B T -6 5 'íZ S-CUBED Division RADIATION HARDENED HYBRID NUCLEAR EVENT DETECTOR Model HSN-1000 FEATURES • Detects ionizing radiation pulses • Tested/certified detection threshold level • Adjustable circumvention period
    OCR Scan PDF
    N Total Ionizing Dose Radiation Data (krads,
    N Total Ionizing Dose Radiation Data (krads, typical) 10 30 50 Analog CMOS Op Amps Bipolar Op Amps Comlinear Comparators Data Acquisition References Regulators Low Dropout Voltage Regulators Motor Drivers Phased Lock Loops (PLL) ASIC CMOS Gate Array (.65µm)
    Original PDF
    sg137
    SGR137 / SGR137A 1.5 Amp Negative Adjustable Regulator Features Description The SGR137/SGR137A is fit, form and function compatible to the SG137/SG137A with the addition of guaranteed performance after radiation exposure to Total Ionizing Dose (TID), Enhanced Low Dose Rate
    Original PDF
    ut7q512
    UTMC Application Note _____________________________________________________________ A Radiation Tolerant 4M SRAM for Space Applications Abstract Total ionizing dose and heavy ion single event effects data are presented for a radiation tolerant 100ns 4M SRAM (UT7Q512). The SRAM is shown to be resistant to between 20 and 35krad(Si) of total dose radiation (depending on the particular lot examined) at a relatively high dose rate of 46rad(Si)/s. The SRAM is
    Original PDF
    dose
    ELDRS-Free Bipolar Analog Products national.com/space Enhanced Low Dose Rate Sensitivity It has been shown that for many types of integrated circuits, the response to total ionizing dose (TID) radiation is dependent on the dose rate. Many bipolar products have been shown to exhibit
    Original PDF
    lm136a-2.5qml
    LM136A-2.5QML www.ti.com SNOSAM3D – JULY 2007 – REVISED OCTOBER 2010 LM136A-2.5QML 2.5V Reference Diode Check for Samples: LM136A-2.5QML FEATURES 1 • 2 • Available with radiation guarantee – Total Ionizing Dose 100 krad(Si) – ELDRS Free 100 krad(Si)
    Original PDF
    hsn-500
    HSN-500 Nuclear Event Detector VB 8 9 Threshold Adjust VH VL 14 1 10 kΩ Detector (Pin Diode) BIT 6 Amplifier 2 NED Pulse Timer LED 7 GND 5 C 4 RC DESCRIPTION: • Maxwell Technologies’ HSN-500 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses
    Original PDF
    LM117HVQML www.ti.com SNVS357C – MARCH 2006 –
    LM117HVQML www.ti.com SNVS357C – MARCH 2006 – REVISED SEPTEMBER 2011 LM117HVQML 3-Terminal Adjustable Regulator Check for Samples: LM117HVQML FEATURES 1 • 2 • Available with radiation guarantee – Total Ionizing Dose 100 krad(Si) – Low Dose Rate Qualified 100 krad(Si)
    Original PDF
    Crane Aerospace & Electronics Power Solutions
    Crane Aerospace & Electronics Power Solutions SMTR Single and Dual DC-DC Converters 28 VOLT INPUT – 30 WATT FEATURES Radiation tolerant space dc-dc converter • Single event effects (SEE) LET performance to 86 MeV cm2/mg • Total ionizing dose (TID) guaranteed to 100 krad(Si)
    Original PDF
    sa50-120
    SA50-120 Single Series RADIATION HARDENED ISOLATED DC/DC CONVERTERS SA50-120 50 Watts Total Power 120 Vdc in—3.3, 5, 28Vdc out DESCRIPTION The SA series of DC-DC converters are designed for the rigors of space, characterized for Total Ionizing Dose and Single Event Effects. Operating
    Original PDF
    SA50-120 Single Series RADIATION HARDENED
    SA50-120 Single Series RADIATION HARDENED ISOLATED DC/DC CONVERTERS SA50-120 50 Watts Total Power 120 Vdc in—3.3, 5, 28Vdc out DESCRIPTION The SA series of DC-DC converters are designed for the rigors of space, characterized for Total Ionizing Dose and Single Event Effects. Operating
    Original PDF