OXIME Search Results
Documents mentioning OXIME
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| afe4400 | AFE4400 www.ti.com SBAS601D – DECEMBER 2012 – REVISED MAY 2013 Integrated Analog Front-End for Heart Rate Monitors and Low-Cost Pulse Oximeters Check for Samples: AFE4400 FEATURES APPLICATIONS • 23 • Fully-Integrated Analog Front-End for |
Original | ||||
| pulse oximeter | Design Considerations for the Analog Front End of a Pulse Oximeter Matthew Hann Senior Applications Engineer Texas Instruments, Tucson hann_matthew@ti.com 1 of 81 Pulse oximetry is a technique used to measure the oxygen saturation in blood and other vital signs such as ECG and pulse rate. Aside from its obvious clinical uses, |
Original | ||||
| pulse oximetry | Medical Applications Guide Diagnostic, Patient Monitoring and Therapy Digital Stethoscopes Patient Monitoring ECG and EEG Pulse Oximetry Ventilation CPAP Dialysis Machine Infusion Pump AED www.ti.com/medical 2Q 2009 2 Medical Applications Guide ➔ Table of Contents |
Original | ||||
| oximeter | PHOTONIC DETECTORS INC. Four Drive Emitter, Oximeter Component (880/660/940 nm) Type PDI-E839 Criticare, Data Scope, NovaMetrix,Ohmeda& Scimed capable PACKAGE DIMENSIONS INCH (mm) .265 [6.73] CL .161 [4.08] CL .133 [3.37] CL .105 [2.65] .075 [1.90] .055 [1.40] |
Original | ||||
| Product Folder Sample & Buy Support & Community | Product Folder Sample & Buy Support & Community Tools & Software Technical Documents AFE4403 SBAS650B – MAY 2014 – REVISED JULY 2014 AFE4403 Ultra-Small, Integrated Analog Front-End for Heart Rate Monitors and Low-Cost Pulse Oximeters 1 Features 2 Applications |
Original | ||||
| pulse oximeter | Pulse oximeter (PO or SpO2) analog front end module for the C5505 PO or SpO2 medical development kit The TMDXMDKPO8328 pulse oximeter (PO or SpO2) analog front end (AFE) module is part of the PO medical development kit (MDK), which consists of the PO AFE module, a processor board (C5505 DSP |
Original | ||||
| oximeter | PHOTONIC Pulsed Oximeter, Silicon Photodiode, DETECTORS INC. Photoconductive Type PDB-C166 PACKAGE DIMENSIONS INCH (mm) METALIZED CERAMIC 2 SIDES PHOTODIODE CHIP .268 [6.81] C ANODE SOLDER PAD .289 [7.34] CATHODE SOLDER PAD A TOP VIEW CLEAR ENCAPSULATE BOTTOM VIEW |
Original | ||||
| oximeter | PHOTONIC DETECTORS INC. Dual Drive Emitter, Oximeter Component Plastic Lead Frame package (660/920 nm) Type PDI-E831 Nellcor, Datex and BCI capable PACKAGE DIMENSIONS INCH (mm) .177 [4.50] .050 [1.26] .067 [1.70] CLEAR PLASTIC .062 [1.57] .087 [2.21] .095 [2.41] |
Original | ||||
| epm-4001 | Detector Assembly EPM-4001 Silicon Photodiode Lead Frame Construction Pulse Oximetry Component The EPM-4001 Detector Assembly uses a silicon planar diffused photodiode specially designed for medical applications. It features high efficiency and fast response. The EPM4001 Detector Assembly is spectrally matched |
Original | ||||
| mi | Maxim > App Notes > 1- Wire® Devices Amplifier and Comparator Circuits Microcontrollers Keywords: pulse oximetry, pulse ox, pulse monitor, oxygenation, patient monitor Jun 21, 2010 APPLICATION NOTE 4671 Improve sensor performance and reduce SNR in pulse oximeter designs |
Original | ||||
| sprab37 | Application Report SPRAB37 – June 2009 Pulse Oximeter Implementation on the TMS320VC5505 DSP Medical Development Kit (MDK) Vishal Markandey… |
Original | ||||
| photonic detectors | PHOTONIC DETECTORS INC. Three Drive Emitter, Oximeter Component (660/905 nm) Type PDI-E834 Nonin capable PACKAGE DIMENSIONS INCH (mm) .205 [5.21] .055 [1.40] .025 [0.64] RED L.E.D. WIRE BOND I.R. L.E.D. .225 [5.71] METALIZED CERAMIC SUBSTRATE CLEAR ENCAPSULATE |
Original | ||||
| afe4490 | AFE4490 www.ti.com SBAS602A – DECEMBER 2012 – REVISED JANUARY 2013 Integrated Analog Front-End for Pulse Oximeters Check for Samples: AFE4490 FEATURES APPLICATIONS • DESCRIPTION The AFE4490 is a fully-integrated analog front-end |
Original | ||||
| afe4490 | AFE4490 www.ti.com SBAS602B – DECEMBER 2012 – REVISED FEBRUARY 2013 Integrated Analog Front-End for Pulse Oximeters Check for Samples: AFE4490 FEATURES 1 • Package: Compact QFN-40 (6 mm × 6 mm) Specified Temperature Range: –40°C to +85°C APPLICATIONS |
Original | ||||
|
|
||||||
| spirometer | Maxim > App Notes > Battery Management Microcontrollers Keywords: spirometer, pulse oximetry, FVC, FEV1, PEF, asthma testing, emphysema testing, cystic fibrosis testing, electrical components, block diagram May 10, 2010 APPLICATION NOTE 4688 Introduction to spirometers and important design considerations for |
Original | ||||
| oximeter | PHOTONIC DETECTORS INC. Dual Drive Emitter, Oximeter Component Plastic Lead Frame package (660/895 nm) Type PDI-E830 Nellcor, Datex and BCI capable PACKAGE DIMENSIONS INCH (mm) .177 [4.50] .050 [1.26] .067 [1.70] CLEAR PLASTIC .062 [1.57] .087 [2.21] .095 [2.41] |
Original | ||||
| Technical Data Sheet LOCTITE® Superflex® | Technical Data Sheet LOCTITE® Superflex® Non-Corrosive RTV Silicone November-2004 PRODUCT DESCRIPTION LOCTITE® Superflex® Non-Corrosive RTV Silicone provides the following product characteristics: Technology Silicone Chemical Type Oxime silicone Appearance (uncured) Clear paste |
Original | ||||
| glucometer | Lighting Management for Portable Application 1 Market for portable lighting Blood Pressure Meter Mp3 Player Glucometer Gaming Device Lighting Pulse CO-Oximeter Satellite Radio Cellphone Digital Camera Barcode Scanner GPS Handheld Scope 2 What’s new for portable |
Original | ||||
| an4327 | Freescale Semiconductor Application Note Document Number: AN4327 Rev. 1, 09/2011 Pulse Oximeter Fundamentals and Design by: Santiago Lopez RTAC Americas Guadalajara Mexico 1 Introduction This application note demonstrates implementation of a basic pulse oximeter using Freescale products. The pulse |
Original | ||||
| electrocardiogram | Low-power signal chain solutions based on C5505 DSP for portable medical application development Electrocardiogram (ECG), Pulse Oximeter (PO) and Digital Stethoscope (DS) Medical Development Kits The portable medical applications market is growing rapidly and companies with limited |
Original | ||||