OVERLOAD MOELLER Search Results
OVERLOAD MOELLER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TLV1117CKCS | Texas Instruments | Single Output LDO, 800mA, Fixed and Adj., Internal Current limit, Thermal Overload Protection 3-TO-220 0 to 125 |
|
|
|
| TLV1117IDCYR | Texas Instruments | Single Output LDO, 800mA, Fixed and Adj., Internal Current limit, Thermal Overload Protection 4-SOT-223 -40 to 125 |
|
|
|
| TLV1117-18CDRJR | Texas Instruments | Single Output LDO, 800mA, Fixed and Adj., Internal Current limit, Thermal Overload Protection 8-SON 0 to 125 |
|
|
|
| TLV1117-25CDCY | Texas Instruments | Single Output LDO, 800mA, Fixed and Adj., Internal Current limit, Thermal Overload Protection 4-SOT-223 0 to 125 |
|
|
|
| TLV1117-50CDCYG3 | Texas Instruments | Single Output LDO, 800mA, Fixed and Adj., Internal Current limit, Thermal Overload Protection 4-SOT-223 0 to 125 |
|
|
Documents mentioning OVERLOAD MOELLER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| relays | -cE3-2002 13=29 FROM MOELLER ELECTIC LTN TO 01132794449 P.02 MoeHerHPI0211-2001/2002 06/025 Z Overload Relays, Current-Transformer Operated Overload Relays, Thermistor Overload Relays Re lays Dimensions Overload relays Overload / Motor-Protective Z5-…/FF250 |
OCR Scan | ||||
| hpl0211-2001 | Moeller HPL0211-2001/2002 06/001 Overload relays, motor-protective relays Technical overview Page 06/002 System overview 05/006 Overload relays, motor-protective relays ZE, Z00 overload relays Z1, Z5 overload relays ZW7 current transformer-operated overload relays |
Original | ||||
| zb150 | Type: ZB150−150 Article No.: 278466 Sales text Overload relay 120−150 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 120…150 Auxiliary contacts N/O = Normally open |
Original | ||||
| zb150 | Type: ZB150−35 Article No.: 278461 Sales text Overload relay 25−35 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 25…35 Auxiliary contacts N/O = Normally open |
Original | ||||
| zb150 | Type: ZB150−125 Article No.: 278465 Sales text Overload relay 95−125 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 95…125 Auxiliary contacts N/O = Normally open |
Original | ||||
| pkzm01 | Type: PKZM01−0,16 Article No.: 278475 Ordering information Motor rating AC−3 690 V P kW 0.06 Rated uninterrupted current Iu A 0.16 Overload release, min. – Overload release, max. Ir A 0,1 – 0,16 Irm A 2,2 max. Notes concerning the product group Accessories |
Original | ||||
| dilm32 | Type: ZB32−2,4 Article No.: 278448 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, |
Original | ||||
| dilm32 | Type: ZB32−6 Article No.: 278450 Ordering information Overload release, min. – max. Ir A 4–6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| dilm32 | Type: ZB32−1,6 Article No.: 278447 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| dilm32 | Type: ZB32−1 Article No.: 278446 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| zb12 | Type: ZB12−12 Article No.: 278441 Ordering information Overload release, min. – max. Ir A 9 – 12 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
| m160 | Type: NZMN2−M160 Article No.: 265724 Sales text Circuit−breaker 3p 160A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 125…160 Short−circuit release 1280…2240 |
Original | ||||
| zb12 | Type: ZB12−2,4 Article No.: 278437 Ordering information Overload release, min. – max. Ir A 1,6 – 2,4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
| zb12 | Type: ZB12−1,6 Article No.: 278436 Ordering information Overload release, min. – max. Ir A 1 – 1,6 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
|
|
||||||
| zb12 | Type: ZB12−10 Article No.: 278440 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
| dilm32 | Type: ZB32−16 Article No.: 278452 Ordering information Overload release, min. – max. Ir A 10 – 16 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| dilm32 | Type: ZB32−24 Article No.: 278453 Ordering information Overload release, min. – max. Ir A 16 – 24 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| m200 | Type: NZMN2−M200 Article No.: 265725 Sales text Circuit−breaker 3p 200A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 160…200 Short−circuit release 1600…2500 |
Original | ||||
| dilm32 | Type: ZB32−4 Article No.: 278449 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| dilm32 | Type: ZB32−10 Article No.: 278451 Ordering information Overload release, min. – max. Ir A 6 – 10 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| dilm32 | Type: ZB32−32 Article No.: 278454 Ordering information Overload release, min. – max. Ir A 24 – 32 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 |
Original | ||||
| zb12 | Type: ZB12−1 Article No.: 278435 Ordering information Overload release, min. – max. Ir A 0,6 – 1 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
| zb12 | Type: ZB12−4 Article No.: 278438 Ordering information Overload release, min. – max. Ir A 2,4 – 4 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM7, DILM9, DILM12, DIULM7, DIULM9, DIULM12, SDAINLM12, SDAINLM16, SDAINLM22 |
Original | ||||
| CONTROL GEAR/DIN TERMINALS AC contactors page 239 | CONTROL GEAR/DIN TERMINALS AC contactors page 239 Time delay control blocks page 240 DIN rail terminals page 248 Thermal overload relays page 239 Auxiliary contact blocks 241 Coil suppressor modules 241 Contact blocks 239-241, 244 Contactors 239-241 Control relays |
Original | ||||
| moeller electric | 13 Jul 07 1 3 : 4G Moeller Electric Ltd 0129G 310399 Motor Starter Circuit Diagrams One of these circuit diagrams will apply to this Motor Starter; please note that hatched areas represent the installation of, and final control circuit connections to, the Overload Relay which is available separately. The dotted box around Q1 represents when the starter |
OCR Scan | ||||