NH2GG Search Results
NH2GG Price and Stock
Mersen Electrical Power
Mersen Electrical Power NH2GG50V500Fuse: fuse; NH2; ceramic,industrial; 500A; 500VAC; 250VDC; gG |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
NH2GG50V500 | 26 | 1 |
|
Buy Now | ||||||
Mersen Electrical Power NH2GG40V100-1Fuse: fuse; NH2; ceramic; holders; 100A; 400VAC; gG; silver plated |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
NH2GG40V100-1 | 3 |
|
Get Quote | |||||||
Mersen Electrical Power NH2GG40V125-1Fuse: fuse; NH2; ceramic; holders; 125A; 400VAC; gG; silver plated |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
NH2GG40V125-1 | 3 |
|
Get Quote | |||||||
Mersen Electrical Power NH2GG40V35Fuse: fuse; NH2; ceramic; holders; 35A; 400VAC; gG; silver plated |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
NH2GG40V35 | 3 |
|
Get Quote | |||||||
Mersen Electrical Power NH2GG40V50Fuse: fuse; NH2; ceramic; holders; 50A; 400VAC; gG; silver plated |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
NH2GG40V50 | 3 |
|
Get Quote | |||||||
Documents mentioning NH2GG
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 500V Size 000 to 3 - Isolated Lug NH-fuses, 500VAC gG with isolated metal gripping lugs (SGL), double indicator, contact blades, complying with DIN VDE 0636 Part 201 |
Original | ||||
| 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr | 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 NH-fuses Utilization Categories The utilization category is marked by two letters. The first letter indicates the breaking-capacity range, and the |
Original | ||||
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 690V Size 000 to 3 - Isolated Lug NH-fuses, 690VAC gG with isolated metal gripping lugs (SGL), double indicator, contact blades, complying with DIN VDE 0636 Part 201 and IEC 60269-2-1 |
Original | ||||
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 400V Size 000 to 3 - Isolated Lug NH-fuses, 400VAC gG with isolated metal gripping lugs (SGL),double indicator, contact blades, complying withDIN VDE 0636 Part 201 |
Original | ||||
| Special Purpose Fuses Special Purpose Fuses | Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses Isolating fuse list Imax (kA) one pulse Designation Reference Number Voltage rating (V) Current rating (A) Breaking capacity 1 1 2.5 2.5 3 4.5 4.5 5 5 6.5 6.5 8-10 8-10 8-10 |
Original | ||||
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 500V Size 000 to 4a NH-fuses, 500VAC gG with non-isolated gripping lugs, double indicator, contact blades, complying with DIN VDE 0636 Part 201 and IEC 60269-2-1 |
Original | ||||
| vde 0636 | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| Fuses – Fusegear Semiconductor Protection Fuses • | Fuses – Fusegear Semiconductor Protection Fuses • Protistor Mapping 70 - 71 • American Round Fuses - Form 101 range 72 - 81 • Other American Round Fuses 82 • Ferrule-style Protistor fuses 83 - 87 • Protistor DIN standard fuses sizes 000-00 88 - 89 |
Original | ||||
| General Purpose IEC Fuses General Purpose IEC | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 2 and 3 from 125 to 630 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR or TRIP-INDICATOR • COMPLYING WITH IEC 269.1 and 2.1, NF EN 60269.1 & 2 NF C 63210 - 63211 AND DIN 43620 |
Original | ||||
| vde 0636 | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| nh fuse | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| vde 0636 | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
MEMா Enclosed Switchgear and Motor Control • Fuse-switch-disconnectors & switch disconnectors • Enclosed busbar chambers • HRC distribution fuseboards & fuses Designed with the needs of the installer and building owner in mind • Load break switches |
Original | |||||
|
|
||||||
| vde 0636 | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| iec 60269-2 | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the |
Original | ||||
| Special Purpose Fuses Special Purpose Fuses | Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses PROTECTION AGAINST LOW VOLTAGE ARRESTER FAILURE When an arrester fails (it can no longer contain overvoltage and thus short circuits), a fuse is needed to prevent its explosion. If the fuse is equipped with a trip-indicator, the user will be aware that the arrester |
Original | ||||
| fuses nh | General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Ceramic body with French striker gG 690V Size 0 to 3 gG 500 - 690VAC H216690 Size R223000 X214656 Rated current Rated voltage IN(A) (V) 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 3 3 3 |
Original | ||||