Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NH00GG Search Results

    SF Impression Pixel

    NH00GG Price and Stock

    Mersen Electrical Power

    Mersen Electrical Power NH00GG50V160

    Fuse: fuse; NH00; ceramic,industrial; 160A; 500VAC; 250VDC; gG
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME NH00GG50V160 64 1
    • 1 $5.40
    • 10 $5.40
    • 100 $4.85
    • 1000 $4.85
    • 10000 $4.85
    Buy Now

    Mersen Electrical Power NH00GG50V125

    Fuse: fuse; NH00; ceramic,industrial; 125A; 500VAC; 250VDC; gG
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME NH00GG50V125 56 1
    • 1 $7.25
    • 10 $7.25
    • 100 $6.32
    • 1000 $6.32
    • 10000 $6.32
    Buy Now

    Mersen Electrical Power NH00GG69V125

    Fuse: fuse; NH00; ceramic,industrial; 125A; 690VAC; 250VDC; gG
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME NH00GG69V125 26 1
    • 1 $9.99
    • 10 $9.99
    • 100 $8.75
    • 1000 $8.75
    • 10000 $8.75
    Buy Now

    Mersen Electrical Power NH00GG69V50

    Fuse: fuse; NH00; ceramic,industrial; 50A; 690VAC; 250VDC; gG
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME NH00GG69V50 3 1
    • 1 $9.99
    • 10 $9.99
    • 100 $8.75
    • 1000 $8.75
    • 10000 $8.75
    Buy Now

    Mersen Electrical Power NH00GG69V63

    Fuse: fuse; NH00; ceramic,industrial; 63A; 690VAC; 250VDC; gG
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME NH00GG69V63 2 1
    • 1 $9.67
    • 10 $9.67
    • 100 $9.67
    • 1000 $9.67
    • 10000 $9.67
    Buy Now

    Documents mentioning NH00GG

    Document Partial File Text Tags Type PDF
    38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr
    38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 NH-fuses Utilization Categories The utilization category is marked by two letters. The first letter indicates the breaking-capacity range, and the
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 690V Size 000 to 3 - Isolated Lug NH-fuses, 690VAC gG with isolated metal gripping lugs (SGL), double indicator, contact blades, complying with DIN VDE 0636 Part 201 and IEC 60269-2-1
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 400V Size 000 to 3 - Isolated Lug NH-fuses, 400VAC gG with isolated metal gripping lugs (SGL),double indicator, contact blades, complying withDIN VDE 0636 Part 201
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 500V Size 000 to 4a NH-fuses, 500VAC gG Cd/Pb-free Size 000 000 000 000 000 000 000 000 000 000 000 000 000 000 00 00 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Rated current
    Original PDF
    Special Purpose Fuses Special Purpose Fuses
    Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses Isolating fuse list Imax (kA) one pulse Designation Reference Number Voltage rating (V) Current rating (A) Breaking capacity 1 1 2.5 2.5 3 4.5 4.5 5 5 6.5 6.5 8-10 8-10 8-10
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    Fuses – Fusegear Semiconductor Protection Fuses •
    Fuses – Fusegear Semiconductor Protection Fuses • Protistor Mapping 70 - 71 • American Round Fuses - Form 101 range 72 - 81 • Other American Round Fuses 82 • Ferrule-style Protistor fuses 83 - 87 • Protistor DIN standard fuses sizes 000-00 88 - 89
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 00 from 10 to 160 A • BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR • COMPLYING WITH IEC 269.1 and 2.1 NF EN 60269.1 & 2 NF C 63210 AND DIN 43620 STANDARDS
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 690V Size 000 to 4a NH-fuses, 690VAC gG Cd/Pb-free Size 000 000 000 000 000 000 000 000 000 000 000 000 000 00 00 00 00 00 00 00 00 1 1 1 1 1 1 1 1 1 1 1 1 1
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    nh fuse
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    General Purpose IEC Fuses General Purpose IEC
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V gG 500V Size 000 to 3 - Isolated Lug NH-fuses, 500VAC gG with isolated metal gripping lugs (SGL), double indicator, contact blades, complying with DIN VDE 0636 Part 201
    Original PDF
    MEMா Enclosed Switchgear and Motor Control • Fuse-switch-disconnectors & switch disconnectors • Enclosed busbar chambers • HRC distribution fuseboards & fuses Designed with the needs of the installer and building owner in mind • Load break switches
    Original PDF
    vde 0636
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    iec 60269-2
    General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG 400V, 500V, 690V aM 500V, 690V NH Fuse System DIN 57 636/VDE 0636 Parts 1, 10, 21, 22, 201 IEC 60269-2 DIN 43 620 Parts 1 to 4 (Standard dimensions) The use category is identified by two letters, the first indicating the
    Original PDF
    Special Purpose Fuses Special Purpose Fuses
    Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses PROTECTION AGAINST LOW VOLTAGE ARRESTER FAILURE When an arrester fails (it can no longer contain overvoltage and thus short circuits), a fuse is needed to prevent its explosion. If the fuse is equipped with a trip-indicator, the user will be aware that the arrester
    Original PDF