Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NAMUR NE 21 Search Results

    NAMUR NE 21 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Siemens SN 29500

    Abstract: LIMIT SWITCH namur 43 LIMIT SWITCH namur application siemens CIB Namur switching amplifier ATEX* II 3D IEC 60947-5-6 namur NE 43 EXIDA
    Contextual Info: PI-EX-NAM/RNO-NE Ex-i NAMUR Isolation Amplifier INTERFACE Data Sheet 102883_04_en 1 PHOENIX CONTACT - 02/2008 Description The PI-EX-NAM/RNO-NE is a 3-way isolation amplifier. It is designed to operate proximity switches according to EN 60947-5-6 as well as switch contacts with open circuit


    Original
    PDF

    kfd2-stc1-ex1

    Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
    Contextual Info: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -


    Original
    PDF

    kfd2-stc4

    Abstract: BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 UPR-03 EN 50014 to 50020
    Contextual Info: KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz -3 dB • EMC acc. to NAMUR NE 21


    Original
    PR-03 UPR-03 kfd2-stc4 BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 EN 50014 to 50020 PDF

    KFA6-SR2-Ex2.W

    Abstract: IEC 60947-5-6 KFD2-SR2-Ex2.W KFa5-SR2-Ex2.W kfd2-sr-ex2 atex transformer E 106378 60947-5-6 namur standard kfa5-sr2
    Contextual Info: Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21


    Original
    PDF

    EX-94

    Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
    Contextual Info: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W


    Original
    Signalgebe50 EX-94 kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5 PDF

    kha6-sr2-ex

    Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
    Contextual Info: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21


    Original
    PDF

    DW-AD-403-04

    Abstract: DW-AD-401-04 detecteur de proximite inductif DW-AD-404-04 DW-AD-402-04 DW-AS-401-04 DW-AS-402-04 DW-AS-404-04 Contrinex namur DW-AS-405-04
    Contextual Info: data sheet Induktiver Näherungsschalter Détecteur de proximité inductif Inductive Proximity Switch DW - A - 40 - 04 Durchmesser Diamètre Diameter 4 mm Miniaturausführung Durchmesser 4 mm glatt Appareil miniature Boîtier lisse de 4 mm de diamètre Wichtigste Eigenschaften:


    Original
    PDF

    KFD2-SR2-Ex1.W

    Abstract: IEC 60947-5-6 kfd2-eb2 NE44 IEC 60947-5-6 NAMUR 60947-5-6 kfd2 Pepperl Fuchs kfd2 EN50-020 Ignition Transformer
    Contextual Info: Transformer Isolated Barriers KFD2-SR2-Ex1.W Output: Relay Input I EEx ia IIC 3400 Ω ≤ R ≤ 2 kΩ 1+ Switch S3 in position I without SC • • • • 1-channel Control circuit EEx ia IIC Reversible mode of operation 1 relay output with 1 changeover


    Original
    PDF

    namur NE 21

    Abstract: MF740 DIN19234 kfd2-sr-ex2 la 7610
    Contextual Info: A U T O M A T I O N C Transformer Isolated Barrier KFD2-SR2-Ex2.W _Output: Relay € - Dual Channel Input I EEx ia IIC Input II EEx ia IIG - Hazardous Field Circuit EEx ia MC and Class I, Div 1, Groups A-G - DC 24 V Nominal Power Supply


    OCR Scan
    14AWG) namur NE 21 MF740 DIN19234 kfd2-sr-ex2 la 7610 PDF

    Ex-94

    Abstract: kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234
    Contextual Info: C Transformer Isolated Barrier KFD2-SR2-Ex1.W _Output: Relay € - Single Channel Input EEx ia IIC - Hazardous Field Circuit EEx ia IIC and Class I, Div 1,Groups A-G - DC 24 V Nominal Power Supply ra 1+ - Selectable Mode of Operation


    OCR Scan
    14AWG) Ex-94 kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234 PDF

    KFD2-SR2-Ex2.W

    Abstract: IEC 60947-5-6 NE44 kfd2-eb2 60947-5-6 kfd2 atex transformer Pepperl Fuchs kfd2 Ignition Transformer namur standard
    Contextual Info: Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • • • • 2-channel Control circuit EEx ia IIC


    Original
    PDF

    pbt-gf20 relay

    Abstract: PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X
    Contextual Info: Selection Guide Housing Styles Pages Q5.5 Style 2-Wire DC 3-Wire DC 7-8 9 - 10 Q06 Style 3-Wire DC 11 - 12 Housing Styles Pages Q11S Style 2-Wire DC 3-Wire DC 2-Wire NAMUR 7-8 23 - 24 45 - 46 25 - 26 37 - 38 Q6.5 and Q9.5 Styles 3-Wire DC 13 - 14 Q12 Style


    Original
    B9005 1-800-544-PROX B0143 pbt-gf20 relay PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X PDF

    encodeur incremental

    Abstract: TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique
    Contextual Info: Phoenix Contact GmbH & Co. KG D-32823 Blomberg, Germany Fax +49- 0 5235-341200, Tel. +49-(0)5235-300 www.interface.phoenixcontact.com D GB TNR 9000681-03 / 04.2003 Universal Frequenz-Messumformer Universal Frequency Transducer F Convertisseur de fréquences


    Original
    D-32823 CISPR11 encodeur incremental TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique PDF

    phoenix contact 24v 8 channel Relay

    Abstract: ATEX EN50082-2
    Contextual Info: Two-Channel Switch Amplifier With Relay Output, 24 V DC Power Supply PI/Ex-ME-2NAM/COC-24 V DC 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this


    Original
    PI/Ex-ME-2NAM/COC-24 phoenix contact 24v 8 channel Relay ATEX EN50082-2 PDF

    tuv 00 atex 1527

    Abstract: EN50082-2
    Contextual Info: Two-Channel Switch Amplifier With One Passive TO 700 Hz per Channel PI/Ex-ME-2NAM/TO-700Hz 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this


    Original
    PI/Ex-ME-2NAM/TO-700Hz tuv 00 atex 1527 EN50082-2 PDF

    IEC 60947-5-6

    Abstract: LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float
    Contextual Info: Vibration limit switch Dimensions Ø85 max. 76 L ~25 max. 140 Vibracon LVL-M with plastic housing and process connection Goo 17.5 max. 65 Ø80 max. 60 Vibracon LVL-M NAMUR max. 40.7 max. 173 Vibracon LVL-M with aluminium housing and process connection with flange


    Original
    4435/316L 4435/316L, mm/115 IEC 60947-5-6 LIMIT SWITCH namur application DN100 PN16 KEMA Flow switch CA3 DN40 EN 10204 3.1 DN100-PN40 DN80-PN40 10204 3.1b material certificate namur float PDF

    rosemount temperature sensors

    Abstract: rosemount pt 100 PT-100 RTD 4 wire sensor - rosemount PT-100 RTD 3 wire sensor - rosemount rosemount pt 100 rtd rosemount calibration rosemount calibration pt 100 Rosemount RTD Rosemount ni mh
    Contextual Info: Product Data Sheet 00813-0100-4148, Rev BA May 2008 Rosemount 148 Rosemount 148 Temperature Transmitter • Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions CPS • Increases measurement accuracy and


    Original
    00813-XXXX-XXXXm¤ rosemount temperature sensors rosemount pt 100 PT-100 RTD 4 wire sensor - rosemount PT-100 RTD 3 wire sensor - rosemount rosemount pt 100 rtd rosemount calibration rosemount calibration pt 100 Rosemount RTD Rosemount ni mh PDF

    IEC 60947-5-6

    Abstract: NE44 k400r KFA5
    Contextual Info: Switch Amplifier KFA5-SR2-Ex1.W Assembly Features • • • • • • • 1-channel isolated barrier 115 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection LFD Reversible mode of operation Up to SIL2 acc. to IEC 61508 Front view


    Original
    PDF

    MCR-SL-PT100-LP-I

    Abstract: PT100 application note RTD PT100 3wire PT100 SENSOR pt100 thermometer PT100 temperature transducer 3 wire PT100 IEC 751 pt100 sensors application note pt100 pt100 sensor 2wire
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the


    Original
    PT100 MCR-SL-PT100-LP-I MCR-SL-PT100-LP-I PT100 application note RTD PT100 3wire PT100 SENSOR pt100 thermometer PT100 temperature transducer 3 wire PT100 IEC 751 pt100 sensors application note pt100 pt100 sensor 2wire PDF

    RTD PT100 3wire

    Abstract: MCR-SL-PT100-LP-I pt100 4-20mA pt100 temperature transducers rtd pt100 4-20ma connections MCR-SL-PT100 namur NE 43 pt100 temperature sensor circuit connection Pt100 3 wire Phoenix/pt100 4-20 ma
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the


    Original
    PT100 MCR-SL-PT100-LP-I RTD PT100 3wire MCR-SL-PT100-LP-I pt100 4-20mA pt100 temperature transducers rtd pt100 4-20ma connections MCR-SL-PT100 namur NE 43 pt100 temperature sensor circuit connection Pt100 3 wire Phoenix/pt100 4-20 ma PDF

    relay 12v 500 ohm

    Abstract: zhrv3 1.1kw 3phase 220v
    Contextual Info: SENSORS, PROCESS & MEASUREMENT Short Form Catalogue 2014 I 2015 www.acdc.co.za CONTENTS DIN Rail Mount Voltage Monitors Power Monitors SP-100/SP-103: Current Monitor, Single Phase SP-101/SP-104: Current Monitor, Single Phase SP-120/SP-123: Current Window Comparator, Single Phase


    Original
    SP-100/SP-103: SP-101/SP-104: SP-120/SP-123: SP-121: SP-200/SP-201: SP-220/SP-221: AP-221: AP-224: SP-230/SP-231/SP-232: AP-231/AP-232: relay 12v 500 ohm zhrv3 1.1kw 3phase 220v PDF

    apparatebau hundsbach

    Abstract: ATEX1169 crouse-hinds CEAG ceag ghg 2 en 50082-2 D-77815 ceag ghg atex CE0102 ceag GHG 41
    Contextual Info: Betriebsanleitung 2/942 - Trennschaltverstärker mit Relaisausgang Zielgruppe: erfahrene Elektrofachkräfte gem. Elex V. Operating instructions 2/942 - Switch Amplifier with Relay Output Target group: Experienced skilled electricians according to relevant national


    Original
    D-77815 apparatebau hundsbach ATEX1169 crouse-hinds CEAG ceag ghg 2 en 50082-2 ceag ghg atex CE0102 ceag GHG 41 PDF

    PT100 application note

    Abstract: pt100 sensors PT100 IEC B pt100 thermometer RTD PT100 3wire application note pt100 PT100 temperature transducer 3 wire PT100 temperature sensor class B pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I


    Original
    PT100 MCR-SL-HT-PT100-I MCR-FL-HT-PT100-I PT100 application note pt100 sensors PT100 IEC B pt100 thermometer RTD PT100 3wire application note pt100 PT100 temperature transducer 3 wire PT100 temperature sensor class B pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I PDF

    H703

    Contextual Info: Extract from the online catalog PI-EX-NAM/TO Order No.: 2835574 Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted


    Original