    SF Impression Pixel

    KFA5 Price and Stock

    Select Manufacturer

    Automation Components Inc A-50K-FA-50'-GD

    50,000 Ohm Thermistor, Flexible
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey A-50K-FA-50'-GD Bulk 25 1
    • 1 $675.20
    • 10 $675.20
    • 100 $675.20
    • 1000 $675.20
    • 10000 $675.20
    Buy Now

    Automation Components Inc A-50K-FA-50'-PB

    50,000 Ohm Thermistor, Flexible
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey A-50K-FA-50'-PB Bulk 25 1
    • 1 $675.20
    • 10 $675.20
    • 100 $675.20
    • 1000 $675.20
    • 10000 $675.20
    Buy Now

    Automation Components Inc A-20K-FA-50'-PB

    20,000 Ohm Thermistor, Flexible
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey A-20K-FA-50'-PB Bulk 2 1
    • 1 $675.20
    • 10 $675.20
    • 100 $675.20
    • 1000 $675.20
    • 10000 $675.20
    Buy Now

    NXP Semiconductors PXAG30KFA-512

    IC MCU 16BIT ROMLESS 44PLCC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey PXAG30KFA-512 Tube
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    NXP Semiconductors PXAG30KFA-529

    IC MCU 16BIT ROMLESS 44PLCC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey PXAG30KFA-529 Tube 156
    • 1 -
    • 10 -
    • 100 -
    • 1000 $7.87
    • 10000 $7.87
    Buy Now

    KFA5 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    IEC 60947-5-6

    Abstract: 253VAC EN 50014 to 50020 60947-5-6 signal relay KFA5 kfa5-sr2 pulse transformer circuit
    Contextual Info: WE 77/Ex-1 115V Switch Amplifier Successor KFA5-SR2-Ex1.W Connection • • • • • • 1-channel Control circuit EEx ia IIC 115 V AC supply voltage Reversible mode of operation Lead breakage LB monitoring 1 relay output with 1 changeover contact WE 77/Ex-1 115V


    Original
    77/Ex-1 IEC 60947-5-6 253VAC EN 50014 to 50020 60947-5-6 signal relay KFA5 kfa5-sr2 pulse transformer circuit PDF

    IEC 60947-5-6

    Abstract: NE44 k400r KFA5
    Contextual Info: Switch Amplifier KFA5-SR2-Ex1.W Assembly Features • • • • • • • 1-channel isolated barrier 115 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection LFD Reversible mode of operation Up to SIL2 acc. to IEC 61508 Front view


    Original
    PDF

    BUK444-500A

    Abstract: BUK444-500B transistor BUK444-500B BUK444
    Contextual Info: N AMER PHI LI PS / DI SC R ET E ESE kfa53T31 0DSG37G D 1 BUK444-500A BUK444-500B PowerMOS transistor T - 3 GENERAL DESCRIPTION QUICK REFERENCE DATA N-channel enhancement mode field-effect power transistor in a plastic full-pack envelope. The device is intended for use in


    OCR Scan
    kfa53T31 0DSG37G BUK444-500A BUK444-500B BUK444 -500A -500B BUK444-500B transistor BUK444-500B PDF

    KFA5

    Abstract: class 1 div 2 relay sil relay making a phone case LB1415 k-system
    Contextual Info: KFA5-SR2-Ex1.W Technical Data POWER SUPPLY Terminals 14, 15 Nominal voltage 115 VAC ± 10% 1-Channel with Relay Output Power Consumption 1W INPUT intrinsically safe Terminals 1+, 2+, 3- Nominal Data ≈ 8 VDC/≈ 8 mA Input pulse length/interval ≥ 20 ms/≥ 20 ms


    Original
    PDF

    KFA6-SR2-Ex2.W

    Abstract: IEC 60947-5-6 KFD2-SR2-Ex2.W KFa5-SR2-Ex2.W kfd2-sr-ex2 atex transformer E 106378 60947-5-6 namur standard kfa5-sr2
    Contextual Info: Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21


    Original
    PDF

    53RT2110

    Abstract: ABB variable area flowmeter D10A3220 D10A3225 D163A011U03 10A3225 10A3220 FAM3225 KFa5-SR2-Ex2.W KFA6-SR2-EX2.W
    Contextual Info: Data Sheet D184S042U02 • Function – The armored variable area flowmeter offers new possibilities for metering small flowrates of liquids and gases. The instrument is particularly well suited for metering cloudy, opaque or aggressive fluids. ■ Application


    Original
    D184S042U02 10A3220) D184S042U02 53RT2110 ABB variable area flowmeter D10A3220 D10A3225 D163A011U03 10A3225 10A3220 FAM3225 KFa5-SR2-Ex2.W KFA6-SR2-EX2.W PDF

    kfd2-sr-ex1

    Abstract: KFD2-SR2-EX1.W k-system namur NE 21 VDE 0812 PTB Switch Mode dc to ac Supply circuit DIN19234 EX-94
    Contextual Info: Transformer Isolated Barrier KF -SR2-Ex1.W Output: Relay - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position I 1+ - Reversible mode of operation 3- - 1 Signal output with 1 alternator - EMC per NAMUR NE 21 1+ Switch S3 in position I


    Original
    PDF

    MT3809G

    Abstract: DEK13
    Contextual Info: Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG December, 2014 Models MT3809G & MT3810G Brooks Models MT3809G and MT3810G Metal Tube Variable Area Flowmeters Model MT3809G General Purpose Housing Model MT3809G Model MT3809G


    Original
    X-VA-MT3809G-MT3810G-eng 541B182AAG MT3809G MT3810G MT3809G DEK13 PDF

    variohm

    Abstract: ECG1006 T5FM
    Contextual Info: PHILIPS E C G INC bbS 3 Tafl 0 0 0 3 7 5 S T 17E D E C G 1 0 0 6 n A FM MULTIPLEX STEREO DECODER LOW LEVEL INPUT semiconductors Composit signal amplifier, 38 kHz doubler/ decoder, separation controller, lamp driver. CASE OUTLINE unit: mm EQUIVALENT CIRCUIT


    OCR Scan
    T-77-05-05 ECG1006 ECQ1006 variohm ECG1006 T5FM PDF

    A-6121

    Abstract: 53R2110 A-6131 KFD2-SR2-Ex2.W 2128x ABB variable area flowmeter A6100 0424X A6200 KFD2-SR2-EX1.W
    Contextual Info: Data Sheet Purgemaster 'SNAP-IN' Small Flowmeter SS/A61/A62 Issue 5 Models A6100 & A6200  High strength stainless steel body – the body is corrosion resistant stainless steel, rigidly constructed to maintain tube alignment and resist pipe strain  'SNAP-IN' tube construction


    Original
    SS/A61/A62 A6100 A6200 SS/A61/A62 A-6121 53R2110 A-6131 KFD2-SR2-Ex2.W 2128x ABB variable area flowmeter A6100 0424X A6200 KFD2-SR2-EX1.W PDF

    kfd2-sr-ex2

    Abstract: KFA6-SR2-EX2.W kfd2 EX-94 KFD2-SR2-Ex2.W
    Contextual Info: Transformer Isolated Barrier KF Input ΙΙ - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position Ι - Reversible mode of operation 1+ 3- 4+ 6- - 1 Signal output with 1 alternator Switch S3 in position Ι - EMC per NAMUR NE 21 10 kΩ


    Original
    PDF

    KFD2-STC4-EX2

    Abstract: KFD2-STC4-Ex1 kfd2-eb2 namur driver kfd2-stc4 kfd2 kfd2-scd2 Kfd2-UFC k-system 4-TO-20
    Contextual Info: 1463-2012.qxp:QuarkCatalogTempNew 9/11/12 4:24 PM Page 1463 15 Signal Conditioners and Converters TEST & MEASUREMENT Isolated Intrinsic Safety Barriers K-System Solving a wide range of applications in one system, our K-System barriers guarantee a reliable and economical signal transmission between your field device and the


    Original
    UPR-03 KFD2-STC4-EX2 KFD2-STC4-Ex1 kfd2-eb2 namur driver kfd2-stc4 kfd2 kfd2-scd2 Kfd2-UFC k-system 4-TO-20 PDF

    EX-94

    Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
    Contextual Info: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W


    Original
    Signalgebe50 EX-94 kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5 PDF

    kha6-sr2-ex

    Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
    Contextual Info: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21


    Original
    PDF