LUX ME Search Results
Documents mentioning LUX ME
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| MEC TEST TERMS AND DIMENSIONS 1. Luminance | MEC TEST TERMS AND DIMENSIONS 1. Luminance Resistance: After 2 hours exposure under illumination 400~600 Lux, then to test with 10 Lux and 100 Lux under standard illuminant A (chroma temperature 2854K ). 2. Dark Resistance: Resistance value when the light is turned off for ten seconds. (0 Lux) |
Original | ||||
| photo resistor | MEC PHOTO RESISTOR SPECIFICATION MODEL. NO: MLG5506 Electrical Characteristics Descriptions Photo Resistance at 10 Lux (Ta-25 Symbol RL Dark Resistance After 10 sec Removal of 10 Lux Gamma Value ( ) at 10 ~ 100 Lux RD Min. 4 Typ. - Max. 6 Unit k 0.2 - - M |
Original | ||||
| lux meter | Foot Candle/Lux Meter Accurate light level measurements Plus analog output for capturing readins to a recorder Features: • Accurately displays light level in terms of Fc or Lux over three ranges: Fc (0-200, 0-2000 and 0-5000Fc) and Lux (0-2000, 0-20000, 0-50000Lux) |
Original | ||||
| White LED Products for Transportation | White LED Products for Transportation Applications 1.510 REF 586-4606-801 •Designed for LED Reading Light Applications •Bayonet Base •20 degree circular beam pattern •55 mAmps @ 24 VDC •70 lux @ 1 meter, 350 lux @ 0.5 meters .655 .980 Polycarbonate |
Original | ||||
| TWN-LUX Light Sensor. Light Intensity (LUX) | TWN-LUX Light Sensor. Light Intensity (LUX) Sensor and 3 Wire Output Transmitter. I REG 1 900 ISSO I UP L P E R The TWN-LUX incorporates a silicon photodiode light sensor, in a hermetical sealed case, especially designed for high precision linear applications. The sensor has a flat glass window with a built in colour |
Original | ||||
| lux meter | Application Notes M16C/26A Group Sample Program (Lux Meter) 1. Summary This sample program provides the functionality of a lux, or illuminance meter by using the Renesas Starter Kit for M16C/26A (R0K33026AS000BE) and an extension board. Illuminance meter The extension board used here is a product |
Original | ||||
| 13001cb | White LED Products for Bus Applications 586-4606-801 • Designed for LED reading light applications Bayonet base 20 degree circular beam pattern 55 mAmps @ 24 VDC 70 lux @ 1 meter, 350 lux @ 0.5 meter 13001CB - 12 Volt , 13003CB - 24 Volt ( Preliminary Information ) |
Original | ||||
| 13001cb | White LED Products for Bus Applications 586-4606-801 • Designed for LED Reading Light Applications Bayonet Base 20 degree circular beam pattern 55 mAmps @ 24 VDC 70 lux @ 1 meter, 350 lux @ 0.5 meter 13001CB - 12 Volt , 13003CB - 24 Volt ( Preliminary Information ) |
Original | ||||
| Datalogging Light Meter with PC Interface Measure | Datalogging Light Meter with PC Interface Measure Light Intensity from 0.01 to 20,000 Fc & Lux Capture up to 16,000 readings Features: • Large 3-1/2 Digit (1999 count) multi-function LCD • Selectable units of Foot Candles or Lux • Four measurement ranges with up to 0.01 |
Original | ||||
| 13001cb | White LED Products for Bus Applications 586-4606-801 • Designed for LED Reading Light Applications Bayonet Base 20 degree circular beam pattern 55 mAmps @ 24 VDC 70 lux @ 1 meter, 350 lux @ 0.5 meter 13001CB - 12 Volt , 13003CB - 24 Volt ( Preliminary Information ) |
Original | ||||
| Data Sheet LM-200LED LED Light Meter A | Data Sheet LM-200LED LED Light Meter A professional tester specifically designed to accurately measure light output of the LED light sources. n Lux or Foot-candle user selectable measurement units n Measuring Range to 200,000 Lux or 20,000 Foot candles n Data Hold to freeze reading on the digital display |
Original | ||||
| 13001cb | White LED Products for Bus Applications 586-4606-801 • Designed for LED Reading Light Applications Bayonet Base 20 degree circular beam pattern 55 mAmps @ 24 VDC 70 lux @ 1 meter, 350 lux @ 0.5 meter 13001CB - 12 Volt , 13003CB - 24 Volt ( Preliminary Information ) |
Original | ||||
| l103 | 12.7 +/- 1.5 A B 5.53 +/- .06 152 +/- 3 6.35 +/- 1.5 18.3 +/- .5 Lens-End Lamps Color Temp. Line No. Part No. Volts 1 L103 2.5 2 103-1 2.5 3 L105 5.0 (A) Lux measured at 50mm Telephone: 781-935-4442 Fax: 781-938-5867 Amps (A) Lux 0.350 0.350 0.180 2,000 1,100 |
Original | ||||
| White LED Products for Transportation | White LED Products for Transportation Applications 586-4606-801 • Designed for LED reading light applications Bayonet base 20 degree circular beam pattern 55 mAmps @ 24 VDC 70 lux @ 1 meter, 350 lux @ 0.5 meters 13051C - 12 Volt , 13052C – 24 Volt ( Preliminary Information ) |
Original | ||||
|
|
||||||
| Data Sheet LM-200LED LED Light Meter A | Data Sheet LM-200LED LED Light Meter A professional tester specifically designed to accurately measure light output of the LED light sources. n Lux or Foot-candle user selectable measurement units n Measuring Range to 400,000 Lux or 40,000 Foot candles n Built-in memory with 99 records storage |
Original | ||||
| isl29006 | ISL29006, ISL29007, ISL29008 ® Data Sheet March 28, 2008 Small, Low Power, Current-Output Ambient Light Photo Detect IC FN6282.0 Features • 0.5 lux to 10,000 lux range The ISL29006, ISL29007, and ISL29008 are light-to-current silicon optical sensors combining a photodiode array and a |
Original | ||||
| Surface - Mount Ambient Light Sensor | Surface - Mount Ambient Light Sensor ALS-PDIC15-21B/TR8 Features ‧Monolithic IC containing photodiode and current amplifier ‧Human-eye spectral response and excellent IR-cut (from 700 to 1050 nm) ‧Wide dynamic range: 1 lux to 30,000 lux ‧Excellent output to illuminance linearity |
Original | ||||
| gr-9277bir | GR-9277BIR 1/4" Color Day & Night Infrared Camera Features: Color Day & Night Infrared Weatherproof Camera DIY Kit is Including Camera , Lens , IR LED , Power Adaptor & Braket. 1/4" SHARP Color CCD Resolution of 420 TV Lines Illumination 0.92 Lux at F2.0 Illumination 0 Lux ( IR ON ) |
Original | ||||
| isl29101 | ISL29101 ® Data Sheet July 1, 2008 Small, Low Power, Voltage-Output Ambient Light Photo Detect IC FN6510.0 Features • 0.5 lux to 10,000 lux range The ISL29101 is a low power ambient Light-to-Voltage optical sensor combining a photodiode array, a current |
Original | ||||