Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LINE CONTACTOR 415V Search Results

    LINE CONTACTOR 415V Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AV-THLIN2BNCM-005
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft PDF
    AV-THLIN2BNCM-002.5
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-002.5 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 2.5ft PDF
    AV-THLIN2BNCM-007.5
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-007.5 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 7.5ft PDF
    AV-THLIN2BNCM-015
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-015 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 15ft PDF
    AV-THLIN2BNCM-025
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-025 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 25ft PDF

    Documents mentioning LINE CONTACTOR 415V

    Document Partial File Text Tags Type PDF
    bs5424
    Issued November 1990 B11044 Direct on line (dol) starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with
    Original PDF
    140m
    TECHNICAL DATA BULLETIN 100/140M/193 MCS Short-Circuit Current Ratings Short-Circuit Protection Ratings Starting: Short-circuit protective device: Direct-on-line and reversing Bulletin 140M Motor Circuit Protector (MCP) UL 489 magnetic only Contactor: Bulletins 100-C, 100-D
    Original PDF
    iec292
    Issued November 1990 011-044 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
    Original PDF
    iec292
    Issued March 1997 232-3355 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed
    Original PDF
    dol starter
    Control - Direct-on-Line Starters IP66 Plastic Enclosure Three Phase 400v up to 7.5kW - 400v coil • Smoothly styled modern IP66 enclosed DOL starter, with generous cabling space for easy installation. Combined contactor/overload assembly can be unclipped from DIN rail to ease installation.
    Original PDF
    Bulletin 500 Line Open Type Modular Kits and
    Bulletin 500 Line Open Type Modular Kits and Components Selection Guide Bulletin 500, 500F, 509 NEMA AC Contactors and Starters Product Overview NEMA AC Contactor and Starter Modular Kits and Components NEMA sizes 0…4 for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available.
    Original PDF
    bs54
    Issued March 1994 017-064 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    415va
    Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    iec158
    Issued March 1997 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated
    Original PDF
    3 phase
    Star / Delta selections for 415v 3 phase motors Motor F.L.C. against power at 415v based on average typical motors Star / delta components for customer assembly Note: Star / delta kit includes timer, power connections and mechanical interlock Complete starters
    Original PDF
    eh145
    Across the line contactors Type A, B & EH 1 B9 – B75, A95 – A110 • AC 1000 – 2/97 • CONTACTORS: Selection: 1.4 - 1.7 EH145 – EH800 Maximum UL/CSA horsepower ratings • Maximum UL/CSA horsepower ratings
    Original PDF
    Lighting Contactors 37-1 Lighting Contactors June
    Lighting Contactors 37-1 Lighting Contactors June 2008 CA08102001E Contents Description Page Open Control CN35 Electrically Held… C30CN Mechanically Held…
    Original PDF
    re
    B17064 Issued March 1994 Directonline(DOL)starters 0.5to10hp415VacProtectedtoIP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated enclosure environmentally protected to IP66. The
    Original PDF
    Motor Control Motor Control 13 Motor Control
    Motor Control Motor Control 13 Motor Control Contactors, Starters and Brakes… Adjustable Frequency AC Drives… Synchronous…
    Original PDF
    Definite Purpose Contactors and Starters 0–40A
    Definite Purpose Contactors and Starters 0–40A Compact Contactor 4.1 Product Overview—Contactors and Starters Product Overview… Application Description…
    Original PDF
    dcb5a
    Technical Specification English Issue 2 Powerbrake Terminal functions DCB5A D.C. Injection Brake Unit A1 A2 N.B. The DCB5A is fully interchangeable with the former DCB5. The DCB5 was identified by a light grey enclosure with a black lid. The DCB5A is all light grey.
    Original PDF
    Catalogue Number Description DCB15400 15kW dc
    Catalogue Number Description DCB15400 15kW dc injection brake control and power module, 400v control Powerbrake DCBU / DCPM is a modular system for D.C. Injection Braking of 400V three-phase motors from 7.5 to 75 Kw. Each installation will consist of a universal braking control module DCBU and one of
    Original PDF
    GE Consumer & Industrial Power Protection New
    GE Consumer & Industrial Power Protection New ASTAT XT Digital soft starters for 3ph standard induction motors GE imagination at work ASTAT XT ASTAT XT D Digital soft starters for 3ph standard induction motors in Digital Soft Starters G new ASTAT XT solid state soft starter features microprocessor control
    Original PDF
    Accessories & Modification Codes 16-1 Accessories
    Accessories & Modification Codes 16-1 Accessories & Modification Codes April 2008 Contents 16 Description Page Accessories IT. NEMA… Freedom NEMA…
    Original PDF
    Application Guide Motor Starting Solutions Open
    Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete Range of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection… Type 1 or 2 coordination guaranteed between contactors and short-circuit
    Original PDF
    Technical Specification English } P3 P4 } DCPM
    Technical Specification English } P3 P4 } DCPM heatsink temperature (n.c. contact, opening when temperature is high) P5 Thyristor fail detect (link to P3 to disable e.g. with old DCPM) P1 P2 Powerbrake DCBUA / DCPM D.C. Injection Brake System Issue 2 Thermistor connections
    Original PDF
    193-e
    Bulletin 300 NEMA AC Contactors and Components Selection Guide Bulletin 300 NEMA AC Contactors Selection Guide Table of Contents Description Page NEMA AC Contactors Bulletin 300 Feed-Through Wiring For Motor Loads… 3 Bulletin 193-EE — E1 Plus Solid-State Overload Relay…
    Original PDF
    Low Consumption 100-C Contactors and 700-CF
    Low Consumption 100-C Contactors and 700-CF Control Relays with Electronic DC Control Contactors and Control Relays with Unmatched Low Holding Power Rockwell Automation has expanded its successful line of industrial contactors and control relays with a new low-consumption coil. The
    Original PDF
    IEC Contactors and Starters IEC Contactors and
    IEC Contactors and Starters IEC Contactors and Starters 1.1 XT IEC Power Control Product Overview… Relays and Timers…
    Original PDF
    Magnetic Contactors and Starters General
    Magnetic Contactors and Starters General information 01 FUJI low-voltage contactors and starters are available in a broad choice of types, from high-performance to economy, for all consumer and industrial needs. For standard applications, we offer the highperformance SC series. We offer the
    Original PDF