Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INVASIVE Search Results

    Documents mentioning INVASIVE

    Document Partial File Text Tags Type PDF
    non-invasive
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 non-invasive filling level control sensor levelprox
    Original PDF
    lem current
    LEM CURRENT TRANSDUCERS M o d u les H A 400-SR U , H A 400-SR I H A 500-SR U , H A 500-SR I (T ru e RM S O u tp u ts ) Definition - Principle The LEM type HA400SR and HA500SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and
    OCR Scan PDF
    LEM CURRENT TRANSDUCERS Module LTA 100-PR
    LEM CURRENT TRANSDUCERS Module LTA 100-PR (Instantaneous and True RMS Outputs) Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided
    OCR Scan PDF
    non-invasive
    Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 non-invasive filling level control sensor levelprox
    Original PDF
    lem current
    HEMEL I, InternationalÊÊÊ LEM CURRENT TRANSDUCERS Module LTA 100P/SP1 lo7- (Instantaneous Outputs). Definition - Principle T he L EM type LTAIOOP/SPI is a transducer em ploying the Hall Effect to m easure D C and com plex w aveform A C currents in a non invasive m a n n e r Galvanic isolation is provided betw een the primary (m easured) and the analogue
    OCR Scan PDF
    lg216
    Datasheet LG216 Pressure Resistant Milliliter Flow Sensor   1 Maximum flow up to 20 ml/min Resolutions in the µl-Range Flow path made of glass and PEEK™ only Maximum pressure up to 20 bar (290 psi) Introduction LG216 The LG216 Liquid Flow Sensor series enables fast, non invasive measurements of low liquid flow rates up to
    Original PDF
    liquid flow sensor
    Datasheet OEM Sensor LG16-2000HC-D Microfluidic Flow Sensor for Hydrocarbons  1 Liquid flow rates up to 80 ml/min Calibrated for Isopropanol alcohol Totally non invasive Digital I²C interface Introduction LG16 The LG16 Liquid Flow Sensor series enables fast, non invasive measurements of very low liquid flow rates below
    Original PDF
    slaa274
    SLAA274 – November 2005 A Single-Chip Pulsoximeter Design Using the MSP430 Vincent Chan, Steve Underwood… MSP430 Products This application report discusses the design of non-invasive optical plethysmography
    Original PDF
    WINSLOW ADAPTICs Data Sheet – SSOP/TSOP Delta
    WINSLOW ADAPTICs Data Sheet – SSOP/TSOP Delta Clip Introducing the Winslow Delta Clip… The new Winslow Delta Clip provides an accurate, mechanically non-invasive method of attaching to integrated circuit leads with spacings as low as 0.5mm. The Delta Clip has compressible wedge-shaped
    Original PDF
    ColdFire® Microprocessor Applications Integrated
    ColdFire® Microprocessor Applications Integrated Operating Theater MCF548x ColdFire® Microprocessor Applications Overview The complexity of components that operating theaters require continues to increase due to the development of minimally invasive techniques in surgery.
    Original PDF
    blood pressure
    New Hospital Grade Self Contained Non-Invasive Blood Pressure Module on Display at MDM West in Anaheim, February 10-12, 2009 December 2008—Schaumburg, IL USA—Omron Electronic Components LLC announces the availability of the M3600 Non-Invasive Blood Pressure (NIBP) module and software which
    Original PDF
    m3600
    M3600 NIBP Module M3600 NIBP Module (shown without cover) The Omron® M3600 module is a self-contained Non-Invasive Blood Pressure (NIBP) module that combines the hardware and software necessary to perform complete blood pressure measurements. The M3600 NIBP module takes measurements from adults,
    Original PDF
    S E C T I O N 1 0 : T H E R M A L- R I B B O N S
    S E C T I O N 1 0 : T H E R M A L- R I B B O N S ™ • Fast response surface sensing in aerospace, medical, and industrial devices • Thin, flexible RTDs and thermocouples offer easy, non-invasive installation • Rugged laminated construction for use in extreme environments
    Original PDF
    lem current
    LEM CURRENT TRANSDUCERS Module LTA 50-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 50-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided
    OCR Scan PDF
    lem current
    LEM CURRENT TRANSDUCERS Module LTA 100-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 100-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided
    OCR Scan PDF
    LEM CURRENT TRANSDUCERS M o d u les HAL *** S
    LEM CURRENT TRANSDUCERS M o d u les HAL *** S Definition - Principle T*^ LEM type HAL *** S are transducers em ploying the Hall effect to measure DC and com plex waveform AC current in a n i-invasive manner. Galvanic isolation is provided between the primary (measured) and the analogue output (control) signal.
    OCR Scan PDF
    AD8 / AD9 Series Ultrasonic air bubble and
    AD8 / AD9 Series Ultrasonic air bubble and air-in-line sensors FEATURES · Non-invasive pulse-type ultrasonic technology · Compact design features integral programmable micro-controller · High accuracy and reliability · Dry coupled, no coupling gel required
    Original PDF
    nibp
    PND Series Switching solenoid dump valve FEATURES · 2-way Normally Open exhaust valve in a small package size · Works well in miniature applications such as in Non-Invasive Blood Pressure (NIBP) devices · Provides small size and low cost · Offers low holding voltage
    Original PDF
    nibp
    XFPM(NIBP) Data sheet Pre-amplified/5V Excitation/Gauge Features… Applications . Non-invasive Blood Pressure(NIBP)monitors . Medical device Accuracy, 1.0 FS Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span
    Original PDF