| non-invasive | Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 non-invasive filling level control sensor levelprox |
Original | ||||
| lem current | LEM CURRENT TRANSDUCERS M o d u les H A 400-SR U , H A 400-SR I H A 500-SR U , H A 500-SR I (T ru e RM S O u tp u ts ) Definition - Principle The LEM type HA400SR and HA500SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and |
OCR Scan | ||||
| LEM CURRENT TRANSDUCERS Module LTA 100-PR | LEM CURRENT TRANSDUCERS Module LTA 100-PR (Instantaneous and True RMS Outputs) Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| non-invasive | Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 non-invasive filling level control sensor levelprox |
Original | ||||
| lem current | HEMEL I, InternationalÊÊÊ LEM CURRENT TRANSDUCERS Module LTA 100P/SP1 lo7- (Instantaneous Outputs). Definition - Principle T he L EM type LTAIOOP/SPI is a transducer em ploying the Hall Effect to m easure D C and com plex w aveform A C currents in a non invasive m a n n e r Galvanic isolation is provided betw een the primary (m easured) and the analogue |
OCR Scan | ||||
| lg216 | Datasheet LG216 Pressure Resistant Milliliter Flow Sensor 1 Maximum flow up to 20 ml/min Resolutions in the µl-Range Flow path made of glass and PEEK™ only Maximum pressure up to 20 bar (290 psi) Introduction LG216 The LG216 Liquid Flow Sensor series enables fast, non invasive measurements of low liquid flow rates up to |
Original | ||||
| liquid flow sensor | Datasheet OEM Sensor LG16-2000HC-D Microfluidic Flow Sensor for Hydrocarbons 1 Liquid flow rates up to 80 ml/min Calibrated for Isopropanol alcohol Totally non invasive Digital I²C interface Introduction LG16 The LG16 Liquid Flow Sensor series enables fast, non invasive measurements of very low liquid flow rates below |
Original | ||||
| slaa274 | SLAA274 – November 2005 A Single-Chip Pulsoximeter Design Using the MSP430 Vincent Chan, Steve Underwood… MSP430 Products This application report discusses the design of non-invasive optical plethysmography |
Original | ||||
| WINSLOW ADAPTICs Data Sheet – SSOP/TSOP Delta | WINSLOW ADAPTICs Data Sheet – SSOP/TSOP Delta Clip Introducing the Winslow Delta Clip… The new Winslow Delta Clip provides an accurate, mechanically non-invasive method of attaching to integrated circuit leads with spacings as low as 0.5mm. The Delta Clip has compressible wedge-shaped |
Original | ||||
| ColdFire® Microprocessor Applications Integrated | ColdFire® Microprocessor Applications Integrated Operating Theater MCF548x ColdFire® Microprocessor Applications Overview The complexity of components that operating theaters require continues to increase due to the development of minimally invasive techniques in surgery. |
Original | ||||
| blood pressure | New Hospital Grade Self Contained Non-Invasive Blood Pressure Module on Display at MDM West in Anaheim, February 10-12, 2009 December 2008—Schaumburg, IL USA—Omron Electronic Components LLC announces the availability of the M3600 Non-Invasive Blood Pressure (NIBP) module and software which |
Original | ||||
| m3600 | M3600 NIBP Module M3600 NIBP Module (shown without cover) The Omron® M3600 module is a self-contained Non-Invasive Blood Pressure (NIBP) module that combines the hardware and software necessary to perform complete blood pressure measurements. The M3600 NIBP module takes measurements from adults, |
Original | ||||
| S E C T I O N 1 0 : T H E R M A L- R I B B O N S | S E C T I O N 1 0 : T H E R M A L- R I B B O N S ™ • Fast response surface sensing in aerospace, medical, and industrial devices • Thin, flexible RTDs and thermocouples offer easy, non-invasive installation • Rugged laminated construction for use in extreme environments |
Original | ||||
| lem current | LEM CURRENT TRANSDUCERS Module LTA 50-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 50-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
|
|
||||||
| lem current | LEM CURRENT TRANSDUCERS Module LTA 100-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 100-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| LEM CURRENT TRANSDUCERS M o d u les HAL *** S | LEM CURRENT TRANSDUCERS M o d u les HAL *** S Definition - Principle T*^ LEM type HAL *** S are transducers em ploying the Hall effect to measure DC and com plex waveform AC current in a n i-invasive manner. Galvanic isolation is provided between the primary (measured) and the analogue output (control) signal. |
OCR Scan | ||||
| AD8 / AD9 Series Ultrasonic air bubble and | AD8 / AD9 Series Ultrasonic air bubble and air-in-line sensors FEATURES · Non-invasive pulse-type ultrasonic technology · Compact design features integral programmable micro-controller · High accuracy and reliability · Dry coupled, no coupling gel required |
Original | ||||
| nibp | PND Series Switching solenoid dump valve FEATURES · 2-way Normally Open exhaust valve in a small package size · Works well in miniature applications such as in Non-Invasive Blood Pressure (NIBP) devices · Provides small size and low cost · Offers low holding voltage |
Original | ||||
| nibp | XFPM(NIBP) Data sheet Pre-amplified/5V Excitation/Gauge Features… Applications . Non-invasive Blood Pressure(NIBP)monitors . Medical device Accuracy, 1.0 FS Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span |
Original | ||||