IGNITOR XENO Search Results
Documents mentioning IGNITOR XENO
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| k105 | K105 THRU K260 FRONTIER ELECTRONICS CO., LTD. SIDAC (95 – 270 VOLTS) FEATURES ! GLASS PASSIVATED JUNCTIONS ! HIGH SURGE CURRENT CAPABILITY ! DO-15 PACKAGE 1.0(25.4) MIN .034(0.9) .028(0.7) APPLICATIONS ! GAS IGNITOR ! XENON IGNITORS ! HIGH VOLTAGE LCMP IGNITORS |
Original | ||||
| pl5632 | PHILIPS PL5632 /C3J THYRATROH ; xenon-filled triode with negative control characteristic THYRATRON; triode à remplissage de xenon avec caractériristique de commande négative STROMTORRÖHRE; Triode mit Xenonfüllung mit negativer Steuer kennlinie Application: Relay service, motor control, ignitor firing |
OCR Scan | ||||
| pl5684 | PHILIPS PL5684 /C3 JA THYRATRON; xenon-fllled triode with negative control characteristic THYRATRON; triode à remplissage de xenon avec caracteriristique de commande négative STROMTORRÖHRE; Triode mit Xenonfüllung mit negativer Steuer kennlinie Application: Relay service, motor control, ignitor firing |
OCR Scan | ||||
| Contents GE Lighting Incandescent Reflector Heat | Contents GE Lighting Incandescent Reflector Heat Lamps 3 Halogen Precise™ MR11, Precise™ ConstantColor™ MR16, Precise™ Bright MR16, Precise™ Alutech™ MR16, TAL 50, UV-Control CeriTite™, DEQ, Halogen IR™ DEQ, Haloglobe & BTT, Halo T, PAR 30 |
Original | ||||
| cep300axe | DATASHEET Lighting Solutions CEP300AXE, CEP300BXE, CEP300CXE and CEP300FXE 300W XENON POWER SUPPLY with PFC Key Features Line Input: 100 - 240 VAC, ± 10%, 50 - 60 Hz, 6.5 Arms max. Environmental: 0°C to 40°C operating. Altitude: -1,000 ft. to 12,000 ft. |
Original | ||||
| cep301axe | DATASHEET Lighting Solutions CEP301AXE, CEP301BXE, CEP301CXE, CEP301AHX, CEP301BHX, and CEP301CHX 300W Xenon Power Supply with 12V and 5V Auxiliary Outputs Key Features Line Input: 100 - 240 VAC, ± 10%, 50 - 60 Hz, 6.5 Arms max. Environmental: 0° C to 50° C |
Original | ||||
| DATASHEET Lighting Solutions CE300AXE, CE300BXE, | DATASHEET Lighting Solutions CE300AXE, CE300BXE, and CE300CXE XENON POWER SUPPLY Key Features The CE300AXE, CE300BXE, and CE300CXE power supplies are designed to run xenon arc lamps in a constant-power mode. The CE300 power supply is designed to run xenon arc lamps in a constantpower mode. The supply is designed to run the Osram XBO 300 and |
Original | ||||
| do-214 | E9 DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 Sidac (79 V to 330 V) RoHS E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||
| sidac | E9 DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 Sidac (79 V to 330 V) RoHS E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||
| sidac | DO-214AA Surface Mount TO-202AB Type 1 TO-92 Type 70 Do not use m ounting tab or center lead, electrically connected SIDAC (95 - 330 Volts) General Description The Sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon |
OCR Scan | ||||
| do-15x | DO-15X Axial Lead DO-214AA Surface Mount TO-202AB Type 1 TO-92 Type 70 Do not use mounting tab or center lead, electrically connected SIDAC (95 - 330 Volts) 9 General Description The Sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon |
Original | ||||
| sidac | E9 DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 Sidac (79 V to 330 V) E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||
| E9 DO-15X DO-214 Surface Mount TO-92 Type 70 | E9 DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 Sidac (79 V to 330 V) E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||
| D O -2 1 4 A A S u r fa c e M o u n t T O -2 0 2 | D O -2 1 4 A A S u r fa c e M o u n t T O -2 0 2 A B Type 1 T O -9 2 T ype 70 D o n o t u s e m o u n tin g ta b o r c e n te r le a d , e le c t r ic a lly c o n n e c te d SIDAC (95 - 330 Volts) General Description T h e S id a c is a s ilic o n b ila te ra l v o lta g e trig g e re d s w itc h w ith |
OCR Scan | ||||
|
|
||||||
| Do not use m ounting tab or center lead, | Do not use m ounting tab or center lead, electrica lly connected SIDAC (95 - 330 Volts) General Description The Sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the Sidac breakover voltage |
OCR Scan | ||||
| sidac | Axial Lead Sidac TO-92 Features • AC circuit oriented • Glass passivated junctions • High surge current capability SIDAC 95-280 Volts General Description The Sidac is a silicon bilateral voltage-triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the breakover voltage point, the Sidac switches |
Original | ||||
| electronic measurements inc | ELECTRONIC MEASUREMENTS INC. euxe DATA SHEET FOR USE WITH X E NON ARC LAMPS AT POWER LEVELS F R O M 35W TO 1000W The ELXE series of power supplies is of constant current, or constant power mode, utilizing switch mode technology for igniting and operating Xenon Arc |
OCR Scan | ||||
| SIDAC (95 - 330 Volts) Genera! Description The | SIDAC (95 - 330 Volts) Genera! Description The Sidac is a silicon bilateral voltage triggered sw itch with greater pow er-handling capabilities than standard diacs. Upon application of a voltage exceeding the Sidac breakover voltage point, the Sidac sw itches on through a negative resistance region |
OCR Scan | ||||
| sidac | DO-15X Axial Lead DO-214AA Surface Mount TO-202AB Type 1 Do not use mounting tab or center lead, electrically connected TO-92 Type 70 SIDAC (95 - 330 Volts) 9 General Description The Sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon |
Original | ||||
| sidac | E9 DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 Sidac (79 V to 330 V) E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||
| sidac | STC SIDAC Series DO-15X DO-214 Surface Mount TO-92 Type 70 TO-202 E9 General Description The sidac is a silicon bilateral voltage triggered switch with greater power-handling capabilities than standard diacs. Upon application of a voltage exceeding the sidac breakover voltage |
Original | ||||