Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IGBT JUNCTION TEMPERATURE CALCULATION Search Results

    IGBT JUNCTION TEMPERATURE CALCULATION Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-316SMAX200-001
    Amphenol Cables on Demand Amphenol CO-316SMAX200-001 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 1ft PDF
    CO-316SMAX200-003
    Amphenol Cables on Demand Amphenol CO-316SMAX200-003 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 3ft PDF
    CO-316SMAX200-004
    Amphenol Cables on Demand Amphenol CO-316SMAX200-004 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 4ft PDF
    CO-316SMAX200-010
    Amphenol Cables on Demand Amphenol CO-316SMAX200-010 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 10ft PDF
    CO-316SMAX200-005
    Amphenol Cables on Demand Amphenol CO-316SMAX200-005 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 5ft PDF

    Documents mentioning IGBT JUNCTION TEMPERATURE CALCULATION

    Document Partial File Text Tags Type PDF
    fast diode
    Technische Information / Technical Information Schnelle Diode für hartschaltende GCT/IGBT Umrichter Fast Diode for hard-switched GCT/IGBT converters D 1031 SH 45T S Features • Specially designed for snubberless operation • 140°C maximum junction temperature
    Original PDF
    an2008-01
    Application Note, V1.0, 2008 AN2008-01 Technical Information IGBT Modules Definition and use of junction temperature values Industrial Power We Listen to Your Comments Any information within this document that you feel is wrong, Your feedback will help us to continuously improve the
    Original PDF
    November 1997 No.12 Hitachi Power Devices
    November 1997 No.12 Hitachi Power Devices Technical Information PD Room This month, we will present a third story in the IGBT Dead Time Series. The subject is: "Effects of collector current and junction temperature on switching delay time." 1) Examining influential parameters with a simplified delay time calculation equation
    Original PDF
    anip9931e
    ANIP9931E Calculation of major IGBT operating parameters CALCULATION OF MAJOR IGBT OPERATING PARAMETERS This application note covers how to calculate major IGBT operating parameters - power dissipation; - continuous collector current; - total power losses;
    Original PDF
    power integration with new econo-pim igbt modules
    Power Integration with new Econo-PIM IGBT Modules Calculation of junction-temperatures for rectifier-diodes, IGBT’s and freewheeling-diodes in the PIM A. Schulz, N. Dittmann, M. Loddenkötter, Th. Schütze eupec, Max-Planck-Straße 5, 59581 Warstein M. Feldvoß
    Original PDF
    APPLICATION NOTE CALCULATION OF THE LOSSES IN A
    APPLICATION NOTE CALCULATION OF THE LOSSES IN A CHOPPER TOPOLOGY by T. Castagnet 1. INTRODUCTION In chopper applications, the components which dissipate power are: • the input rectifier bridge; • the free wheeling diode; and 2. CALCULATION OF THE LOSSES IN ONE
    Original PDF
    semisel
    Application Note AN-8004 Revision: 00 Issue Date: 2008-05-21 Prepared by: Dr. Arendt Wintrich Key Words: SemiSel, Semiconductor Selection, Loss Calculation www.Semikron.com/Application/ Software release of SemiSel version 3.1 New semiconductor available… 1
    Original PDF
    Calculation of the Maximum Virtual Junction
    Calculation of the Maximum Virtual Junction Temperature Reached Under Short-time or Intermittent Duty1) Under short-time or intermittent load higher current ratings are permissible for the power semiconductors than those given in the data sheets for continuous operating. It is,
    Original PDF
    an-7520
    Numerical Method for Evaluating IGBT Losses Application Note January 2000 AN-7520 Authors: Alain Laprade and Ron H. Randall Title N98 bt ume al tho or alung BT sses utho exder aig) eyrds ume al tho or alung BT sses, errpoon, minctor, a- An analysis is presented describing a numerical algorithm
    Original PDF
    an9881
    Numerical Method for Evaluating IGBT Losses Application Note January 2000 AN9881 Authors: Alain Laprade and Ron H. Randall An analysis is presented describing a numerical algorithm that develops loss prediction techniques for IGBTs operating in switched mode power circuits. A 600W zero-current
    Original PDF
    an-7520
    Numerical Method for Evaluating IGBT Losses Application Note January 2000 AN-7520 Authors: Alain Laprade and Ron H. Randall /Title AN75 0) Subect Nume ical etho for valuting GBT osse ) Autho Alexnder raig) Keyords Nume ical etho for valuting GBT osse , nteril
    Original PDF
    Hard-Switched Silicon IGBTs? Cut Switching Losses
    Hard-Switched Silicon IGBTs? Cut Switching Losses in Half with Silicon Carbide Schottky Diodes by Jim Richmond Replacing the Si Ultrafast soft-recovery diode used as the freewheeling component in hard-switched IGBT applications with a Silicon Carbide (SiC) Schottky diode reduces the switching losses in the diode by 80% and the switching
    Original PDF
    APPLICATION NOTE Hard Switched Silicon IGBT’s?
    APPLICATION NOTE Hard Switched Silicon IGBT’s? Cut Switching Losses in Half with Silicon Carbide Schottky Diodes By Jim Richmond Replacing the Si Ultrafast soft recovery diode used as the freewheeling component in hard switched IGBT applications with a Silicon Carbide (SiC) Schottky diode
    Original PDF
    Aut o moti ve I GB T M odule Applic atio n N ote
    Aut o moti ve I GB T M odule Applic atio n N ote Explanation of Technical Information AN 201 0 -0 9 Revison 1.0 Elect ric D rive T rain Edition Revison 1.0 Published by Infineon Technologies AG 81726 Munich, Germany © 2010 Infineon Technologies AG All Rights Reserved.
    Original PDF
    an2008-03
    Application Note, V1.0, 2008 AN2008-03 Thermal equivalent circuit models replaces AN2001-05 Industrial Power Edition 2008-06-16 Published by Infineon Technologies AG 59568 Warstein, Germany © Infineon Technologies AG 2008. All Rights Reserved. LEGAL DISCLAIMER
    Original PDF
    mitsubishi semiconductors power modules mos
    MITSUBISHI SEMICONDUCTORS POWER MODULES MOS GENERAL CONSIDERATIONS FOR IGBT AND INTELLIGENT POWER MODULES 3.0 General Considerations for IGBT and Intelligent Power Modules H-Series IGBT and Intelligent Power Modules are based on advanced third generation IGBT and free-wheel
    Original PDF
    Calculation of the Maximum Virtual Junction
    Calculation of the Maximum Virtual Junction Temperature Reached Under Short-time or Intermittent Duty1) Under short-time or intermittent load higher current ratings are permissible for the power semiconductors than those given in the data sheets for continuous operating. It is,
    Original PDF
    By Michael O’Neill, Applications Engineer, Cree
    By Michael O’Neill, Applications Engineer, Cree Inc., Durham, N.C. Silicon carbide enables the creation of nearperfect high-voltage diodes whose speed and power-handling capabilities open new applications in variable-frequency motor drives. This will lead to higher density power modules that
    Original PDF
    Application Note Applying IGBTs Applying IGBTs
    Application Note Applying IGBTs Applying IGBTs Application Note Björn Backlund, Raffael Schnell Ulrich Schlapbach, Roland Fischer Evgeny Tsyplakov ABB Switzerland Ltd Semiconductors February 08 Table of Contents: 1 APPLYING IGBTS… 3
    Original PDF
    an-990
    Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements… 1 I. A Impact of the impedance of the gate drive circuit on switching losses… 1
    Original PDF
    an-990
    Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements… 1 I. A Impact of the impedance of the gate drive circuit on switching losses… 1
    Original PDF
    int990
    Index INT990 Application® Characterization of IGBTs (HEXFRED is a trademark of International Rectifier) Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature
    Original PDF
    INT990 Application® Characterization of IGBTs
    INT990 Application® Characterization of IGBTs (HEXFRED is a trademark of International Rectifier) Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature
    Original PDF
    powerex igbt
    Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 3.0 General Considerations for IGBT and Intelligent Power Modules Powerex IGBT and Intelligent Power Modules are based on advanced low loss IGBT and free-wheel diode technologies. The general
    Original PDF
    ixan0070
    IXAN0070 Drive with the IXYS XPT IGBT IXYS used its expertise to design the optimal IGBT for motor drives applications By Iain Imrie, Jeroen van Zeeland, Ulrich Kelberlau, Vladimir Tsukanov and Elmar Wisotzki IXYS Corporation IXYS introduces the XPT IGBT, IXYS newest generation of short-circuit rated IGBTs with paralleling
    Original PDF