I11C Search Results
I11C Price and Stock
Lanberg
Lanberg CA-HDMI-11CC-0005-BKCable; HDMI plug,both sides; PVC; 3D,4K,ARC,CEC 2.0; 0.5m; black |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
CA-HDMI-11CC-0005-BK | 155 | 1 |
|
Buy Now | ||||||
Lanberg CA-HDMI-11CC-0018-BKCable; HDMI plug,both sides; PVC; 3D,4K,ARC,CEC 2.0; 1.8m; black |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
CA-HDMI-11CC-0018-BK | 62 | 1 |
|
Buy Now | ||||||
Lanberg CA-HDMI-11CC-0050-BKCable; HDMI plug,both sides; PVC; 3D,4K,ARC,CEC 2.0; 5m; black |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
CA-HDMI-11CC-0050-BK | 39 | 1 |
|
Buy Now | ||||||
Lanberg CA-HDMI-11CC-0030-BKCable; HDMI plug,both sides; PVC; 3D,4K,ARC,CEC 2.0; 3m; black |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
CA-HDMI-11CC-0030-BK | 23 | 1 |
|
Buy Now | ||||||
Lanberg CA-HDMI-11CC-0010-BKCable; HDMI plug,both sides; PVC; 3D,4K,ARC,CEC 2.0; 1m; black |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
CA-HDMI-11CC-0010-BK | 21 | 1 |
|
Buy Now | ||||||
Documents mentioning I11C
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| l497 | rZ 7 SGS-THOMSON L497 y !O T © œ s HALL EFFECT PICKUP IGNITION CONTROLLER ■ DIRECT DRIVING OF THE EXTERNAL PO W ER DARLINGTON ■ COIL CURRENT CHARGING ANGLE (dwell) CONTROL ■ PROGRAMMABLE COIL CURRENT PEAK LIMITATION ■ PROGRAMMABLE DWELL RECOVERY TIME |
OCR Scan | ||||
| l497 | L497 ® HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT |
Original | ||||
| l497 | L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED |
Original | ||||
| sy69952 | V OC-3/STS-3 CLO CK RECOVERING TRA N SC EIVER SYNERGY SY69952 SEMICONDUCTOR DESCRIPTION FEATURES ■ A complete ATM compatible single chip Transmitter & Receiver Synergy's SY69952 contains fully integrated transmitter and receiver functions designed to provide clock recovery |
OCR Scan | ||||
| ad1334 | ANALOGDEVICES fAX-ON-DEMAND HOTLINE - Page 20 Four-Channel 12-BitSamplingAIDConverter r. ANALOG L8II DEVICES forDigitalSignalProce~ing AD1334 FEATURES I BLOCK DIAGRAM Four-Channel AID Converter for DSP Includes: Simultaneous or Independent Sampling Capability |
Original | ||||
| ul497 | UNISONIC TECHNOLOGIES CO., LTD UL497 Preliminary LINEAR INTEGRATED CIRCUIT HALL EFFECT PICKUP IGNITION CONTROLLER DESCRIPTION As an integrated electronic ignition controller for breakerless ignition systems which uses Hall effect sensors, the UTC UL497 |
Original | ||||
| UNISONICTECHNOLOGIESCO., LTD UL497 ̈ Preliminary | UNISONICTECHNOLOGIESCO., LTD UL497 ̈ Preliminary LINEAR INTEGRATED CIRCUIT DESCRI PT I ON As an integrated electronic ignition controller for breakerless ignition systems which uses Hall effect sensors, the UTC UL497 drives an NPN external darlington to control the coil current |
Original | ||||
| tbr-21 | V.22bis TBR-21 Embedded Modem 2430RD Designer’s Guide Rev. 1.0 March, 2001 Information contained in this document is provided in connection with Clare Inc. (Clare) Products and is believed to be accurate and reliable. However, Clare assumes no responsibility for this material’s use, errors or emissions or for any |
Original | ||||
| AC Drives and Soft Starters Pricing Guide | AC Drives and Soft Starters Pricing Guide 8800PL9701R01/14 2014 Class 8800 Altivar 61 Altivar 312 Altistart 48 Altivar 71 E-Flex Altivar 12 S-Flex 212 Altistart 22 Altistart 01 M-Flex PowerGard Altivar 32 CONTENTS Description… Page |
Original | ||||
| fm497 | FM497 Hall Effect Pickup Ignition Controller Specification Oct. 2007 FM497 Hall Effect Pickup Ignition Controller Ver 2.0 Specification 1 INFORMATION IN THIS DOCUMENT IS INTENDED AS A REFERENCE TO ASSIST OUR CUSTOMERS IN THE SELECTION OF SHANGHAI FUDAN MICROELECTRONICS CO., LTD PRODUCT BEST SUITED TO THE CUSTOMER'S APPLICATION; THEY DO |
Original | ||||
| V.22bis North American Embedded Modem 2420RD | V.22bis North American Embedded Modem 2420RD Designer’s Guide Rev. 1.0 March, 2001 Information contained in this document is provided in connection with Clare Inc. (Clare) Products and is believed to be accurate and reliable. However, Clare assumes no responsibility for this material’s use, errors or emissions or for any |
Original | ||||
| l497 | L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED |
Original | ||||
| l497 | L497 ® HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT |
Original | ||||
| l497 | L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED |
Original | ||||
|
|
||||||
| l497 | rZ 7 * 7# S G S -T H O M S O N R (UKgTTISMIKSS L497 HALL EFFECT PICKUP IGNITION CONTROLLER . DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON - COIL CURRENT CHARGING ANGLE (dwell) CONTROL ■ PROGRAMME COIL CURRENT PEAK LIMITA TION . PROGRAMMABLE DWELL RECOVERY TIME |
OCR Scan | ||||
| l497 | L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED |
Original | ||||