EN62053 Search Results
Documents mentioning EN62053
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| em11 | Energy Management Energy Analyzer Type EM11 DIN • Class 1 (kWh) according to EN62053-21 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy analyzer • Instantaneous variables readout: 4 DGT • Energies: 5+1 DGT |
Original | ||||
| en62053-21 | Energy Management Energy Analyzer Type EM11 DIN • Other versions available (not certified, option X): see “how to order” on the next page • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 |
Original | ||||
| Energy Management Energy Meter Type EM21 72D • | Energy Management Energy Meter Type EM21 72D • Class B (kWh) according to EN50470-3 • Class 1 (kWh) according to EN62053-21 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy meter • Instantaneous variables readout: 3 DGT |
Original | ||||
| em11 | Energy Management Energy Analyzer Type EM11 DIN • Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003). • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 |
Original | ||||
| em10 | Energy Management Energy Meter Type EM10 DIN • Class 1 (kWh) according to EN62053-21 • Energy meter • Energy: 5+1 DGT • Energy measurements: total kWh • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply • Dimensions: 1-DIN module |
Original | ||||
| Energy Management Energy Analyzer Type EM26 96 • | Energy Management Energy Analyzer Type EM26 96 • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5% RDG (current/voltage) • Dual colour backlight: no backlight, blue or white (selectable) |
Original | ||||
| em23 | Energy Management Energy Meter Type EM23 DIN • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy analyzer • Instantaneous variables readout: 3 DGT |
Original | ||||
| modbus-rtu | Energy Management Power Analyzer Type WM14 DIN “Advanced version” • Protection degree (front): IP40 • 2 digital outputs • 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs • RS422/485 serial output (MODBUS-RTU), iFIX SCADA |
Original | ||||
| energy | Energy Management Modular Smart Power Quality Transducer Type PQT-H • Up to 12 optional digital inputs (sync function, remote digital input control) • Up to 16 optional digital outputs (pulse, alarm, remote control) • 16 freely configurable alarms with OR/AND logic linkable with up to 4 relay outputs and up to 16 open collector outputs |
Original | ||||
| Schneider Electric Solar Business Catalog 2013 / | Schneider Electric Solar Business Catalog 2013 / 2014 In 2013, Schneider Electric demonstrates its long-term commitment to the development of the Solar industry with the launch of many new products and solutions. These new offers address the needs expressed by customers |
Original | ||||
| Energy Management Smart Modular Power Analyzer | Energy Management Smart Modular Power Analyzer Type WM40 96 • Front dimensions: 96x96 mm • Front protection degree: IP65, NEMA4x, NEMA12 • Optical front communication port (ANSI type 2) • Up to one RS232 or RS485 port (on request) • Communication protocol: MODBUS-RTU, iFIX SCADA |
Original | ||||
| Energy and Time Counters, electromechanical | Energy and Time Counters, electromechanical Energy and Time Counter – HW 66 / HW 66 M (MID) AC 115 / 230 V 12345 000000 - 20° + 55° 65 DIN 48 x 48 Supply Temperature voltage AC DIN Front panel High IP value 000000 push 12345 no reset Timer Innovative: |
Original | ||||
| Energy Management Energy Analyzer Type EM24 DIN • | Energy Management Energy Analyzer Type EM24 DIN • Protection degree (front): IP50 • RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility • Dupline communication capability (DP option) • Application adaptable display and programming |
Original | ||||
| an2264 | AN2264 APPLICATION NOTE Three-Phase SMPS for low power applications with VIPer12A Introduction Some industrial applications require a so called 'ultra-wide' input voltage range (between 90 and 450Vac). Due to the variations of the main, input voltages up to 450Vac are typical in threephase applications. A maximum input voltage of 450Vac requires the use of very high voltage |
Original | ||||
|
|
||||||
| 2659 Technical portal and online community for | 2659 Technical portal and online community for Design Engineers - www.element-14.com Process Control, Timers & Counters Page Process Control Analogue Signal Conditioners… Current and Voltage Controls… DIN / Energy - Meters… |
Original | ||||
| Energy Management Power Analyzer Type WM14 96 | Energy Management Power Analyzer Type WM14 96 “Advanced version” • Protection degree (front): IP65 • 2 digital outputs • 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs • RS422/485 serial output (MODBUS-RTU), iFIX SCADA |
Original | ||||
| Energy Management Energy Analyzer Type EM24 DIN • | Energy Management Energy Analyzer Type EM24 DIN • Dimensions: 4-DIN modules • Protection degree (front): IP50 • RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility • Application adaptable display and programming procedure (Easyprog function) |
Original | ||||
| Q.2 Power Quality Analyzers Power Quality | Q.2 Power Quality Analyzers Power Quality Electrical power quality is the measurement and analysis of the voltage delivered to customers. These parameters (voltage amplitude, flicker, harmonics, unbalance) describe the voltage waveform and offer very important information about the |
Original | ||||
| linkswitch-tn | LinkSwitch-TN Family ® Non-Isolated Buck or Buck-Boost Converter Solution for Linear/Passive Dropper Replacement SEPTEMBER 2004 UPDATE TYPICAL BUCK CONVERTER APPLICATION OUTPUT CURRENT TABLE PRODUCT(1) Perfect for appliances, utility meters, LED drivers & industrial controls. |
Original | ||||
| cpt-din | Energy M a na gement Compa ct Pow er Tra nsducer Type CPT-DIN “ Adva nced version” • One digital output and RS485 communication port (2 wires only) • 16 freely configurable alarms with OR/AND logic linkable to up to 2 digital outputs • RS422/485/RS232 communication port (MODBUSRTU), iFIX SCADA compatibility |
Original | ||||
| di-80 | DI-80 Design Idea LinkSwitch-TN ® 0.6 W Non-Isolated Utility Meter Power Supply Application Device Power Output Input Voltage Output Voltage Topology Utility Meter LNK302PN 0.6 W 85 – 265 VAC, 47-63 Hz 12 V, 50 mA Buck Design Highlights • Universal AC input voltage range |
Original | ||||
| di-80 | Design Idea DI-80 ® LinkSwitch-TN 0.6 W Non-Isolated Utility Meter Power Supply Application Device Power Output Input Voltage Output Voltage Topology Utility Meter LNK302 0.6 W 85-265 VAC, 47-63 Hz 12 V, 50 mA Buck Design Highlights • |
Original | ||||
| cpt-din | Energy Management Compact Power Transducer Type CPT-DIN “Advanced version” • One digital output and RS485 communication port (2 wires only) • 16 freely configurable alarms with OR/AND logic linkable to up to 2 digital outputs • RS422/485/RS232 communication port (MODBUSRTU), iFIX SCADA compatibility |
Original | ||||