| en61812-1 | Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kV/2. Approved by UL and CSA. Lloyds/NK approvals. Conforms to EMC standards (EN50081-2 and EN50082-2). Six-language instruction manual provided. |
Original | ||||
| en61812-1 | Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kV/2 for Low Voltage, and EMC Directives. Lloyds/NK approvals. Six-language instruction manual provided. Approved by UL and CSA. Broad Line-up of H3CR Series |
Original | ||||
| en61812-1 | Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kV/2. Approved by UL and CSA. Lloyds/NK approvals. Conforms to EMC standards (EN50081-2 and EN50082-2). Six-language instruction manual provided. |
Original | ||||
| modbus-rtu | Energy Management Power Analyzer Type WM14 DIN “Advanced version” • Protection degree (front): IP40 • 2 digital outputs • 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs • RS422/485 serial output (MODBUS-RTU), iFIX SCADA |
Original | ||||
| wm14-96 | Energy Management Power Analyzer Type WM14-96 “Basic Version” • Optional dual pulse output • Alarms (visual only) VLN, An • Optional galvanically insulated measuring inputs • Class 1 (active energy) • Class 2 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) |
Original | ||||
| Energy Management Power Analyzer Type WM14-DIN | Energy Management Power Analyzer Type WM14-DIN “Basic Version” • Optional dual pulse output • Alarms (visual only) VLN, An • Optional galvanically insulated measuring inputs • Class 1 (active energy) • Class 2 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) |
Original | ||||
| energy | Energy Management Modular Smart Power Quality Transducer Type PQT-H • Up to 12 optional digital inputs (sync function, remote digital input control) • Up to 16 optional digital outputs (pulse, alarm, remote control) • 16 freely configurable alarms with OR/AND logic linkable with up to 4 relay outputs and up to 16 open collector outputs |
Original | ||||
| cpt-din | Energy Management Compact Power Transducer Type CPT-DIN “Basic version” • RS232 serial port on request • Alarms (only from serial communication port) VLN, An • Class 2 (active energy) • Class 3 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) |
Original | ||||
| SKYPER 42 R Absolute Maximum Ratings Symbol | SKYPER 42 R Absolute Maximum Ratings Symbol SKYPER ® IGBT Driver Core Supply voltage primary 16 V Input signal voltage (HIGH) Vs + 0.3 V GND - 0.3 V ViL Input signal voltage (LOW) IoutPEAK Output peak current 30 A IoutAVmax Output average current 150 mA fmax |
Original | ||||
| Solid-state Timer H3CR-A DIN 48 x 48-mm | Solid-state Timer H3CR-A DIN 48 x 48-mm Multifunctional Timer with Many Time Ranges and Operating Modes, and Wide Power Supply Ranges A wider power supply range reduces the number of timer models kept in stock. An 11-pin or 8-pin model handles a wide range of |
Original | ||||
| iso1h811 | ISOFACE™ ISO1H811G Galvanic Isolated 8 Channel High-Side Switch Datasheet Revision 2.3, 2013-01-31 Power Management & Multimarket Edition 2013-01-31 Published by Infineon Technologies AG 81726 Munich, Germany © 2013 Infineon Technologies AG All Rights Reserved. |
Original | ||||
| Complete Catalogue 4/2015 Residual current | Complete Catalogue 4/2015 Residual current monitoring in grounded power supply systems with residual current relay type RCM1000V and current transformers type STWA3D Meas uring, C ontr olling, Moni t o r i n g o n h i g h e s t l e v e l Editorial Besser, schneller, innovativer, das ist unsere Maxime bei |
Original | ||||
| Three-phase Voltage Relay K8AB-PW Ideal for | Three-phase Voltage Relay K8AB-PW Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. Switch setting for 3-phase 3-wire or 3-phase 4-wire power |
Original | ||||
| Single-phase Current Relay K8AB-AS Ideal for | Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial heaters and motors. • Monitor for overcurrents or undercurrents. • Manual resetting and automatically resetting supported by one Relay. • Startup lock and operating time can be set separately. |
Original | ||||
|
|
||||||
| Energy Management Smart Modular Power Analyzer | Energy Management Smart Modular Power Analyzer Type WM40 96 • Front dimensions: 96x96 mm • Front protection degree: IP65, NEMA4x, NEMA12 • Optical front communication port (ANSI type 2) • Up to one RS232 or RS485 port (on request) • Communication protocol: MODBUS-RTU, iFIX SCADA |
Original | ||||
| Motor Controllers DMPUC, DIN-Rail Motor | Motor Controllers DMPUC, DIN-Rail Motor Protection Unit • Controlling motor operation • Motor thermal protection • Phase sequence, phase loss, unbalance, locked rotor, stall, earth fault and earth leakage protection • Alarm set-points adjustable by the user |
Original | ||||
| h3cr-a8 | Pó³przewodnikowy przekaŸnik czasowy H3CR Seria wielofunkcyjnych przekaŸników czasowych - DIN 48 x 48 mm Grupa przekaŸników czasowych serii H3CR H3CR H3CR-A Wielofunkcyjny przekaŸnik czasowy H3CR-A H3CR-AS H3CR-AP H3CR-A8 H3CR-A8S H3CR-A8E H3CR-F Podwójny |
Original | ||||
| wm14-din | Power analyzers and Energy Meters Power Analyzer Type WM14-DIN • Optional RS422/485 serial port • Alarms (visual only) VLN, An • Class 2 (active energy) • Class 3 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) • Power analyzer • Display of instantaneous variables: 3x3 digit |
Original | ||||
| iso1h815g | Datasheet, Version 2.0, July 2009 ISOFACE TM ISO1H815G Coreless Transformer Isolated Digital Output 8 Channel 1.2A High-Side Switch Power Management & Drives N e v e r s t o p t h i n k i n g . ISO1H815G Revision History: 2009-07-28 Previous Version: V1.0 |
Original | ||||
| k8ab | Single-phase Voltage Relay K8AB-VS Ideal for voltage monitoring for industrial facilities and equipment. • Monitor for overvoltages or undervoltages. • Manual resetting and automatically resetting supported by one Relay. • One SPDT output relay, 6 A at 250 VAC (resistive load). |
Original | ||||
| Three-phase Phase-sequence Phase-loss Relay | Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with |
Original | ||||
| Three-phase Voltage Relay K8AB-PW Ideal for | Three-phase Voltage Relay K8AB-PW Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. Switch setting for 3-phase 3-wire or 3-phase 4-wire power |
Original | ||||
| ISOFACE™ ISO1I811T Isolated 8 Channel Digital | ISOFACE™ ISO1I811T Isolated 8 Channel Digital Input with IEC61131-2 Type 1/2/3 Characteristics Preliminary Data Sheet Revision 1.0, 2011-03-18 Industrial & Multimarket Edition 2011-03-18 Published by Infineon Technologies AG 81726 Munich, Germany © 2011 Infineon Technologies AG |
Original | ||||
| Datasheet, Version 2.0, July 2009 ISOFACE TM | Datasheet, Version 2.0, July 2009 ISOFACE TM ISO1H816G Coreless Transformer Isolated Digital Output 8 Channel 1.2A High-Side Switch Power Management & Drives N e v e r s t o p t h i n k i n g . ISO1H816G Revision History: 2009-07-28 Previous Version: V1.0 |