PPC-58
Abstract: PPC-18 PPC-14 PPC-19 PPC-46 AC 188 PPC-20 Stancor Stancor* PPC-46 PPC-17
Contextual Info: P R I N T E D C I R C UI T T R A N S F O R M E R S Plug-I n P r i n t e d C i r c u i t S e r i e s APC Type PC Type ✳ Agency Certification Note: UL Recognized File E68100 All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins
|
Original
|
e6810050/60hz115/230vppc-46+10ppc-14ppc-23ppc-58ppc-18ppc-19ac 188ppc-20stancorstancor* ppc-46ppc-17
|
PDF
|
|
Contextual Info: PRINTED CIRCUIT TRANSFORMERS P l u g -I n P ri n ted Ci rcu i t S eri es APC Type PC Type ✳Agency Certification Note: UL Recognized File E68100 All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins STANCOR PART
|
Original
|
e6810050/60hz115/230vppc-14+2ppc-23ppc-58
|
PDF
|
SVI 3104 c
Abstract: UPC1678G ne333 stb 1277 TRANSISTOR equivalent transistor bf 175 NE85635 packaging schematic NE72000 VC svi 3104 NE9000 NE720
Contextual Info: Introduction Small Signal GaAs FETs Power GaAs FETs Small Signal Silicon Bipolar Transistors Power Silicon Bipolar Transistors Silicon Monolithic Circuits GaAs Monolithic Circuits Reliability Assurance Appendix This C atalog is printed on R ecycled Paper California Eastern Laboratories, Inc. reserves the right to make changes to the products or
|
OCR Scan
|
an83301-1ne24615an83302an83303-1+16ne71083ne70083an83901an8530111/86-lnan86104svi 3104 cupc1678gne333stb 1277 transistor equivalenttransistor bf 175ne85635 packaging schematicne72000 vcsvi 3104ne9000ne720
|
PDF
|
apc 1500 VA
Abstract: PPC-18
Contextual Info: P R I N T E D C I R C U I T T R A N S F O R M E R S Plug-In Printed Circuit Series Plug-In Printed Circuit Type APC Type All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins STANCOR PART Primary Sec. NUMBER Style Winding
|
Original
|
50/60hz115/230vppc-46ppc-51+6ppc-11ppc-18ppc-12ppc-47ppc-19apc 1500 va
|
PDF
|
DSW-212
Abstract: DSW-312 DSW-412 SW-210 SW-212 SW-310 SW-312 SW-410 SW-412 SW-510
Contextual Info: www.stancor.com 27 P R I N T E D C I R C UI T T R A N S F O R M E R S “Side- Wi n d e r ” S W / D S W S e r i e s “Side-Winder” SW Dual “Side-Winder” (DSW) All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins
|
Original
|
50/60hz115/230vsw-210dsw-210+11sw-310dsw-310sw-410dsw-410sw-510dsw-212dsw-312dsw-412sw-212sw-312sw-412
|
PDF
|
Vip ct 22A
Abstract: E68100
Contextual Info: SEANCOR Power Transformers PRINTED CIRCUIT TRANSFORMERS “SIDE WINDER” SPLIT BOBBIN— PC MOUNT TRANSFORMERS Stancor offers this compact transformer with primary and secondaries wound side by side. The “ Side Winder” is non-concentrically wound, to
|
OCR Scan
|
115/230vdpc-x-12dpc-y-12dpc-y-15+2vip ct 22ae68100
|
PDF
|
|
Contextual Info: PRINTED CIRCUIT TRANSFORMERS “S i d e-Wi n d er” S W / DS W S eri es “Side-Winder” SW Dual “Side-Winder” (DSW) All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins STANCOR PART Primary Sec. NUMBER Winding
|
Original
|
50/60hz115/230vsw-210dsw-210+5sw-310dsw-310sw-410dsw-410sw-510
|
PDF
|
LB-1216
Abstract: LB-1220 LB-612 Stancor LB-210 LB-6230 LB-634 Stancor LB-612 Stancor LB6230 LB-616
Contextual Info: P R I N T E D C I R C UI T T R A N S F O R M E R S “Low Boy” LB Series Stancor Low Boy Low Profile LB-210 STANCOR Part Sec. Number VA Rated Output Primary Individual Series Winding AC/DC Volts mA Volts mA Parallel Volts mA H DIMENSIONS - INCHES W
|
Original
|
lb-210lb-310lb-610lb-1216+8lb-1220lb-612stancorlb-6230lb-634stancor lb-612stancor lb6230lb-616
|
PDF
|
P-8560
Abstract: Stancor stancor transformer
Contextual Info: POWER TRANSFORMERS P-8559, P-8560, P-8604 SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury. FIRE HAZARD Do not exceed transformer ratings.
|
Original
|
p-8559p-8560p-860450/60hz+4e681007-6873astancorstancor transformer
|
PDF
|
P-8357
Abstract: P8619 P-8389
Contextual Info: SIANCOR Transformer General Information HOW TO DETERMINE SECONDARY AC RMS CURRENT RATINGS The tabular data for the various Rectifier, Control and Filament types of transformers listed in this catalog shows A.C. (R.M.S.) secondary cur rent, unless otherwise indicated, as in the “ RT" and “ TP” series listings.
|
OCR Scan
|
p6134p6375p6376p6377+9p6378p6379p6465p8130p8357p8389p-8357p8619p-8389
|
PDF
|
Stancor p-6378
Abstract: P-8619
Contextual Info: POWER TRANSFORMERS Du al S eco n d ari es Style S Style NV Style C S i n g l e P ri mary, Mu l ti p l e S eco n d ari es All Primaries 50/60 Hz. STANCOR PART Sec. NUMBER A B Style Secondary Volts Amps Primary Volts Insulation Test RMS Volts Termination Primary
|
Original
|
p-8361p-8362p-8618p-8619+3e6810015-230vstancor p-6378
|
PDF
|
SW-520
Abstract: 12V .4A Transformer DSW-336 SW-420 transformer 32V CT 1,5A DSW-316 transformer 120V 12V 8A TRANSFORMER CT 1A 12v DSW-224 DSW-248
Contextual Info: “Side Winder” SW / DSW Series Split Bobbin-Printed Circuit Transformers Single & Dual Primaries SPECIFICATIONS: ! WARNING INPUT: ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result
|
Original
|
115vac50/60hz115/230vacul-506+11to20vsw-52012v .4a transformerdsw-336sw-420transformer 32v ct 1,5adsw-316transformer 120v 12v 8atransformer ct 1a 12vdsw-224dsw-248
|
PDF
|
TTPC-13
Abstract: PCT-77 lb1234 c4115 SW-424 ttpc-2 sidewinder TTPC-8 SW-312 SW-528
Contextual Info: 1024-2012:QuarkCatalogTempNew 8/28/12 2:05 PM Page 1024 TEST & MEASUREMENT 11 Telephone Coupling, Low Profile PC and Split Bobbin PC Transformers Low Profile PC Mount Transformers — Low Boy Series Split Bobbin PC Mount Transformers — Side Winder Series
|
Original
|
mil-t-27pct-33pct-78pct-27+11pct-77pct-76ttpc-13lb1234c4115sw-424ttpc-2sidewinderttpc-8sw-312sw-528
|
PDF
|
SW-520
Abstract: 928-9012 DSW-620 928-0612 lb1240 928-0121 SW-628 928-0123
Contextual Info: Stancor Telephone Coupling, Low Profile PC and Split Bobbin PC Transformers Visti StancorÕs Website at www.stancor.com Split Bobbin PC Mount Transformers Side Winder Series Telephone Coupling/Impedance Matching Transformers Features c c c c Small and Lightweight, All Items Weigh Under 1 Oz.
|
Original
|
lb1224dsw-236lb1234dsw-436+11lb1240dsw-536lb12230dsw-636sw-520928-9012dsw-620928-0612928-0121sw-628928-0123
|
PDF
|
|
|
EMERSON rectifier
Abstract: Stancor p-6378 P-8685 P-8362 Stancor STANCOR PCA-4 P-8619
Contextual Info: P O W E R T R A N S F O R M E R S Dual Secondaries Style A with leads Style S with lugs S i n g l e P r i m a r y, D u a l S e c o n d a r y STANCOR PART Sec. NUMBER A Style NV with lugs Style NH with leads Primaries 50/60 Hz.––Solder Lug Termination Output from Two Secondary Windings
|
Original
|
e6810015-230vemerson rectifierstancor p-6378+5p-8685p-8362stancorstancor pca-4p-8619
|
PDF
|
Stancor tp-2
Abstract: stancor P-8720 P-6461 P-8556 EMERSON rectifier P8651 P4026 PCF-24075 P-8560 P-6134
Contextual Info: P O W E R T R A N S F O R M E R S Single Secondar y Style A with leads Style S with lugs Style NV with lugs Style C with leads All Primaries 50/60 Hz. STANCOR PART Primary Sec. NUMBER Volts A B C D E F G Secondary Volts Amps. Style Insulation Test RMS Volts
|
Original
|
p-8629p-4026p-6133p-6454+16p-6467p-6135p-8385p-6465p-8705p-8389stancor tp-2stancor p-8720p-6461p-8556emerson rectifierp8651p4026pcf-24075p-8560p-6134
|
PDF
|
|
Contextual Info: “Side Winder” SW / DSW Series Split Bobbin-Printed Circuit Transformers Single & Dual Primaries SPECIFICATIONS: ! WARNING INPUT: ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result
|
Original
|
115vac50/60hz115/230vacul-506+1certi120v
|
PDF
|
|
Contextual Info: PRINTED CIRCUIT TRANSFORMERS “L o w Bo y” L B S eri es Stancor Low Boy Low Profile LB-210 STANCOR PART Sec. NUMBER VA A Primary Winding AC/DC Individual Volts mA Rated Output Series Volts mA DIMENSIONS - INCHES Parallel Volts mA H W L MW ML A B Weight
|
Original
|
lb-210lb-310lb-610lb-612 |
PDF
|
sw-448
Abstract: SW-410 SW3120
Contextual Info: P R I N T E D C I R C U I T T R A N S F O R M E R S “Side-Winder” SW/DSW Series Side-Winder SW Single Primary Dual Side-Winder (DSW) Dual Primary All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins STANCOR PART
|
Original
|
50/60hz115/230vsw-210dsw-210+7sw-310dsw-310sw-410dsw-410sw-510sw-448sw3120
|
PDF
|
P-6377
Abstract: P-8362 Stancor p-6378 P-8619 P-8361 Stancor XPTQ2 P-6375 P-8616 P-6379
Contextual Info: POWER TRANSFORMERS Dual Secondaries Style S Style NV Style C Si n g l e P r i m a r y, M u l t i p l e S e c o n d a r i e s All Primaries 50/60 Hz. STANCOR PART Sec. NUMBER Style Secondary Volts Amps A P-6429† C 6.3 6.3 6.3 6.3 C.T. Weight lbs. Agency
|
Original
|
p-6429p-8361p-8362p-8364+10p-8619e6810015-230vp-6377stancor p-6378stancorxptq2p-6375p-8616p-6379
|
PDF
|
P-6308
Contextual Info: POWER TRANSFORMERS S i n g l e S eco n d ary Style A Style S Style NV Style C All Primaries 50/60 Hz. STANCOR PART Primary Sec. NUMBER Volts A B C D E F G H I Secondary Volts Amps. Style Insulation Test RMS Volts DIMENSIONS-INCHES Termination Pri. Sec. H Case
|
Original
|
p-8629p-6133p-6454p-6467+3e68100p-8684p-6308
|
PDF
|
P-8575
Abstract: C2690 P-6469 P-8616 P-6134 P8551 P-8574 P-8397 stancor P-8667 P-8662
Contextual Info: 1023-2012:QuarkCatalogTempNew 8/28/12 2:05 PM Page 1023 11 Power and Rectifier Transformers and Filter Chokes TEST & MEASUREMENT Power Transformers Specifications. Input: 50/60 Hz; Other voltages available as custom designs. Operating Temperature: –40° to +105°C. Class A insulating materials. Designed to meet requirements of UL 506.
|
Original
|
702133tagec-2343c-2690c-2685+12c-2686c-2687p-8575c2690p-6469p-8616p-6134p8551p-8574p-8397stancor p-8667p-8662
|
PDF
|
LB-1240
Abstract: Stancor LB-6230
Contextual Info: “Low Boy” Low Profile Split Bobbin-Printed Circuit Transformers SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury.
|
Original
|
115/230vac50/60hzlb-1240stancor lb-6230 |
PDF
|
SW-328
Abstract: DSW-624 DSW-410 SW-410 SW-216 SW-310 SW-412 SW-520 SW-612 DSW-210
Contextual Info: P R I N T E D C I R C UI T T R A N S F O R M E R S “Side-Winder” SW/DSW Series “Side-Winder” SW Dual “Side-Winder” (DSW) All Single Primaries are 115V 50/60Hz, 6 Pins All Dual Primaries are 115/230V 50/60Hz, 8 Pins STANCOR Rated Output Part Primary
|
Original
|
50/60hz115/230vsw-210dsw-210+11sw-310dsw-310sw-410dsw-410sw-510sw-328dsw-624sw-216sw-412sw-520sw-612
|
PDF
|