Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CYHP001 Search Results

    CYHP001 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: POWR-GARD Blocks and Holders Datasheet lphv POWR-SaFe fuse holders 1000 VDC Specifications Voltage Rating 1000 VDC Amperage Rating 30 A SCCR Rating 20 kA Power Dissipation 4 W Maximum Fuse Type 10 X 38 mm up to 1000 VDC Material Thermoplastic Flammability Rating


    Original
    lphv003lphv0003zlphv004lphv0004z+1lphv0001z PDF

    IEC 269-2-1

    Abstract: fuse 32A 10x38 fuse 32A 10x38 690V 10x38 gg 690V gl-gg fuses 690V fuses 10x38 50A 10 X 38 AM 690V FUSE IEC 269-2 CY10X38G6
    Contextual Info: Cylindrical Fuses Littelfuse fast-acting gL-gG fuses are used for the protection of cables against short circuits. Time-lag (aM) fuses are used for protection of motors. SPECIFICATIONS Standards: IEC 269-2-1 Example part number: CY22X58G50 Size 10 x 38 mm


    Original
    cy22x58g506-100a120ka10x38+15cy10x38gcy10x38g1cy10x38g2cy10x38g4cy10x38g6cy10x38g8iec 269-2-1fuse 32a 10x38fuse 32a 10x38 690v10x38 gg690v gl-gg fuses690vfuses 10x38 50a10 x 38 am 690v fuseiec 269-2 PDF

    LPSC002ID

    Abstract: 600v LPSJ30-2ID LPSM001ID E14721 LPSC001ID LPSC003ID LPSC004ID LPSM002ID LR7316
    Contextual Info: Fuse Blocks, Holders and Accessories POWR-SAFE “Dead Front” Holders SPECIFICATIONS Voltage Rating: 600 Volts Ampere Rating: 30 amperes Interrupting Rating: 200 kA Class CC 100 kA (Midget) Terminal type: Pressure plate Suggested Torque: 15 lb. Wire Range: #6—#14CU


    Original
    e14721lr7316lpsc001lpsc002id+11lpsc002lpsc003idlpsc003lpsc004lpsm001600vlpsj30-2idlpsm001idlpsc001idlpsc004idlpsm002id PDF

    mcl d01 94V0

    Abstract: mcl d01 94vo lcd nec 2501 LD 229 TY 8016 thyristor LNNB001 mcl d01 display mcl d01 94VO 4300 MCL D01 94VO LCD DISPLAY FREE Bucket Elevator Design NH3 GL-GG
    Contextual Info: POWR-GARD PRODUCTS CATALOG Littelfuse The World’s Leading Provider of Circuit Protection Solutions An Exceptional Portfolio Littelfuse is committed to providing every one of our customers with the right solutions to meet all of your circuit protection needs. Makes All the Difference


    Original
    pf101-11mcl d01 94v0mcl d01 94vo lcdnec 2501 ld 229+7ty 8016 thyristorlnnb001mcl d01 displaymcl d01 94vo 4300mcl d01 94vo lcd displayfree bucket elevator designnh3 gl-gg PDF

    Contextual Info: Blocks and Holders Fuse Blocks, Holders and Accessories POWR-SAFE “Dead Front” Holders Features/benefits • • • • • • • • Meets “Dead Front” requirements Mountable on 35mm Din Rail Blown fuse identification Indicating versions only


    Original
    lpsc001idlpsc002idlpsc003idlpsc004id+6lpsm001idlpsm002idlpsm003idlpsm004idlpsc001lpsc002 PDF

    E14721

    Abstract: LPSC003ID LPSM001 LPSC001 LPSC001ID LPSC003 LPSC002ID LPSM001ID 94vo fuse Class CC
    Contextual Info: Blocks and Holders Fuse Blocks, Holders and Accessories POWR-SAFE “Dead Front” Holders Features/benefits • • • • • • • • Meets “Dead Front” requirements and IEC Type IP20 Protection Mountable on 35mm Din Rail Blown fuse identification Indicating versions only


    Original
    lpsc001idlpsc002idlpsc003idlpsc004id+11lpsm001idlpsm002idlpsm003idlpsm004idlpsc001lpsc002e14721lpsm001lpsc00394vofuse class cc PDF

    IEC 269-2-1

    Abstract: IEC 269-2 fuse 32A 10x38 690V fuse 32A 10x38 10x38 gg 690V 690V gl-gg fuses am fuses CY14X51G50 10X38
    Contextual Info: International Products Cylindrical Fuses 500 Volts • 0.5 – 100 Amperes Littelfuse fast acting gL-gG fuses are used for the protection of cables against short-circuits. Time-lag (aM) fuses are used for protection of motors. Specifications


    Original
    cy22x58g506-100a120ka10x38+15cy10x38gcy10x38g1cy10x38g2cy10x38g4cy10x38g6cy10x38g8iec 269-2-1iec 269-2fuse 32a 10x38 690vfuse 32a 10x3810x38 gg690v690v gl-gg fusesam fusescy14x51g50 PDF

    Contextual Info: International Products Cylindrical Fuses 500 Volts • 0.5 – 100 Amperes Littelfuse fast acting gL-gG fuses are used for the protection of cables against short-circuits. Time-lag (aM) fuses are used for protection of motors. Specifications Standards: Example part number:


    Original
    cy22x58g506-100a120ka10x38+6cy10x38gcy10x38g1cy10x38g2cy10x38g4cy10x38g6cy10x38g8 PDF

    Contextual Info: POWR-GARD Blocks and Holders Datasheet lPsm Quick connect powr-safe Fuse holders Specifications Voltage Rating 600 VAC/DC Amperage Rating 30 A Approval UL Recognized File No. E14721 , CSA Certified (File No. LR7316), CCC Approved Terminal Type 1/4” Quick Connect Terminals


    Original
    e14721lr7316lpsm001qcidlpsm0001zqcid+6lpsm002qcidlpsm0002zqcidlpsm003qcidlpsm0003zqcidlpsm004qcidlpsm0004zqcid PDF

    Contextual Info: 2.1 53.34 Fuseblocks — POWR-SAFE Dead Front Holders Dead front LPSC/LPSM powr-safe Fuseholders Features/Benefits • Indicating and non-indicating options available • 1-, 2-, 3- and 4-pole configurations • Easy installation and fuse removal with no additional


    Original
    e14721lr7316powr-sc003idlpsc0003zxid+5lpsc003lpsc004idlpsc0004zxidlpsc004lpsc0002z PDF

    Contextual Info: Cylindrical Fuses Littelfuse fast-acting gL-gG fuses are used for the protection of cables against short circuits. Time-lag (aM) fuses are used for protection of motors. SPECIFICATIONS Standards: IEC 269-2-1 Example part number: CY22X58G50 Size 10 x 38 mm


    Original
    cy22x58g506-100a120ka10x38+6cy10x38gcy10x38g1cy10x38g2cy10x38g4cy10x38g6cy10x38g8 PDF

    LPSM002ID

    Contextual Info: Fuseblocks — POWR-SAFE Dead Front Holders DEAD FRONT LPSC/LPSM POWR-SAFE FUSEHOLDERS Features/Benefits •฀ Indicating฀and฀non-indicating฀options฀available •฀ 1-,฀2-,฀3-฀and฀4-pole฀conigurations •฀ ฀฀


    Original
    lpsm004idlpsm0004zxidlpsm004lpsm0004z+6lpsm003idlpsm0003zxidlpsm003lpsm0003zlpsm002idlpsm0002zxid PDF

    Contextual Info: POWR-GARD Blocks and Holders Datasheet LPHV POWR-SAFE FUSE HOLDERS 1000 VDC Features/Benefits •฀ Touch-safe design offers protection when replacing fuses •฀ Compact design •฀ 35 mm DIN Rail Mountable •฀ Available in 1-, 2-, 3- and 4-pole configurations


    Original
    cyhp001cyhp002cyhp00310x38 PDF

    CYHP001

    Abstract: LPHV001 LPHV002 LPHV003 LPHV004 photovoltaic module IT 8755 midget FUSE
    Contextual Info: Blocks and Holders LPHV Series 1000VDC POWR-SAFE “Dead Front” Holders Product Features 1000VDC rating when used with Littelfuse SPF or FLU midget fuse series 30 amperes rated Mountable on 35mm Din Rail Safe and easy installation and removal of fuses. No special fuse pullers or tools


    Original
    1000vdc10x38mmlphv001lphv002+7lphv003lphv004cyhp0011-800-tec-fusephotovoltaic moduleit 8755midget fuse PDF

    Contextual Info: Fuseblocks — POWR-SAFE Dead Front Holders LPSM QUICK CONNECT POWR-SAFE FUSEHOLDERS Features/Benefits • Dual 1⁄4” Quick Connect Terminals on Top and Bottom of Holder • Meets Dead Front requirements • Mountable on 35 mm DIN Rail • Local LED Indication


    Original
    lpsm001qcidlpsm0001zqcidlpsm002qcidlpsm0002zqcid+5lpsm003qcidlpsm0003zqcidlpsm004qcidlpsm0004zqcidcyhp001 PDF

    Contextual Info: POWR-GARD Blocks and Holders Datasheet LPSC / LPSM POWR-SAFE fuse holders 600 V Features/Benefits • Indicating and non-indicating options available • 1-, 2-, 3- and 4-pole configurations • Easy installation and fuse removal with no additional pullers or tools required


    Original
    lpsm003idlpsm0003zxidlpsm003lpsc0003z+6lpsm001idlpsm0001zxidlpsm001lpsc0002zlpsc003lpsc004id PDF

    CYHP003

    Abstract: CYHP002
    Contextual Info: Fuseblocks — POWR-SAFE Dead Front Holders 1000 vdc lphv fuseholder Features/Benefits • Touch-safe design offers protection when replacing fuses • Compact design • 35 mm DIN Rail Mountable • Available in 1-, 2-, 3- and 4-pole configurations • No fuse pullers or tools required for fuse removal


    Original
    ithv002lphv003lphv004lphv0001z+6lphv0002zlphv0003zlphv0004zcyhp001cyhp002cyhp003 PDF