AVS1ACP08 APPLICATION Search Results
AVS1ACP08 APPLICATION Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 143-4142-11H | Amphenol Communications Solutions | Paladin RPO, DC, 4-Pair, 4 Column, APP | |||
| 143-6262-11H | Amphenol Communications Solutions | Paladin RPO, DC, 6-Pair, 6 Column, APP | |||
| 144-411D-11H | Amphenol Communications Solutions | Paladin RPO, DO, 4-Pair, 10 Column, 1.5mm Wipe, APP | |||
| 144-411G-21H | Amphenol Communications Solutions | Paladin RPO, DO, 4-Pair, 16 Column, 2.25mm Wipe, APP | |||
| 144-812B-21H | Amphenol Communications Solutions | Paladin RPO, DO, 8-Pair, 6 Column, 2.25mm Wipe, APP |
Documents mentioning AVS1ACP08 APPLICATION
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| avs10cb1 | INDEX ST Part No. Farnell Order Code Description AMST62APPST/1 AVS10CB1 AVS1ACP08 BUL49D CDDATASHXXX DBST6ST/4 EFS11 EFS1ACD EFS21 EFS2ACD FLC10-200D L6219 LPR30 MC3403N ST62-CDROM ST7-CDROM ST7MDT1-EPB/UK ST7MDT1-KIT/UK ST7MDT2-EPB/UK ST7MDT2-KIT/UK STP80NS04Z |
Original | ||||
| avs12 | AVS12 ® AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs12 | AVS12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs10 | AVS10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs12 | AVS12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs10 | AVS10 ® AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs10 | AVS10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION ■ A2 ■ TRIAC HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| Æ T S C S -T H O M S O N AVS12 [* ^ (5 & [i(g ïjW | Æ T S C S -T H O M S O N AVS12 [* ^ (5 & [i(g ïjW Î* S AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| avs10 | AVS10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION TRIAC ■ HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| avs12 | AVS12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC PARASITIC FILTER LOW POWER CONSUMPTION TRIAC ■ HIGH EFFICIENCY AND SAFETY SWITCHING |
Original | ||||
| ¿ = 7 S G S -TH O M S O N AVS12 AUTOMATIC VOLTAGE | ¿ = 7 S G S -TH O M S O N AVS12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60HZ FULL COMPATIBILITY . INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION TRIAC ■ HIGH EFFICIENCY AND SAFETY SWITCHING |
OCR Scan | ||||
| SGS'THOMSON HD©lSJ@ilLi(gTniî®R!ID(gi AVS10 | SGS'THOMSON HD©lSJ@ilLi(gTniî®R!ID(gi AVS10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION TRIAC ■ HIGH EFFICIENCY AND SAFETY SWITCHING |
OCR Scan | ||||
| avs10 | S G S -T H O M S O N AVS10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY . INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER . LOW POWER CONSUMPTION TRIAC ■ HIGH EFFICIENCY AND SAFETY SW ITCHING |
OCR Scan | ||||
| Æ T * 7c S C S -T H O M S O N | Æ T * 7c S C S -T H O M S O N [iD©[K](Q)i[L[i(gir®(S)iD©i AVS12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
|
|
||||||
| avs0 | SCR & TRIAC ASDTM : Application Specific Discretes TO220AB SWITCH MODE POWER SUPPLY ASDs Tj max = 110 °C (except AVS08CB: 125 °C) IT(RMS) +-VDRM ITSM Type IDRM @ VDRM @ Tj max AVS kit Suffix VTM @ ITM Comments Package max max (V) (A) (V) (A) (mA) AVS08 5 |
Original | ||||
| ._________________________________________________ | .____________________________________________________________/ / 7 3 S S G S -T H O M S O N noÊ^ûitiitgraraotgi t X ’- lS . AVS 10 AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER… 50/60Hz FULL COMPATIBILITY INTEGRATED VOLTAGE REGULATOR TRIGGERING PULSE TRAIN OF THE TRIAC |
OCR Scan | ||||
| r= 7 S G S -TH O M S O N AVS12 | r= 7 S G S -TH O M S O N AVS12 KSID(g®@lllLll©iIIMDD©i AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| S G S -T H O M S O N [ M © I M S i © ï[ M i D ( g | S G S -T H O M S O N [ M © I M S i © ï[ M i D ( g l A V S 12 AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| /= T mz S C S -TH O M S O N AVS10 [ M © [ ^ © i[ | /= T mz S C S -TH O M S O N AVS10 [ M © [ ^ © i[ L i ( g ? [ l Q M © S AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER . 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR . TRIGGERING PULSE TRAIN OF THE TRIAC . PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| £ = 7 S G S -TH O M S O N AVS10 | £ = 7 S G S -TH O M S O N AVS10 R®D©l^(ô)ll[L[l©'ir[^(ô)liülD©S AUTOMATIC VOLTAGE SWITCH (SMPS < 300W) CONTROLLER ■ 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| avs10 | APPLICATION NOTE HOW TO USE THE AVS KIT PRELIMINARY NOTE I DESCRIPTION OF THE AVS KIT : The AVS10, or AVS12, is an automatic mains selector to be used in on line SMP supply with Power up to 500W. It is made of two devices. The AVS is compatible with 50 and 60 Hz mains |
Original | ||||
| SGS-THOMSON *7 # » AVS12 R ü lD » l[ L I( g ïï[ M | SGS-THOMSON *7 # » AVS12 R ü lD » l[ L I( g ïï[ M iit ie i AUTOMATIC VOLTAGE SWITCH (SMPS < 500W) CONTROLLER ■ 50/60Hz FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION |
OCR Scan | ||||
| an390 | AN390 APPLICATION NOTE HOW TO USE THE AVS KIT DESCRIPTION OF THE AVS KIT The AVS10, or AVS12, is an automatic mains selector to be used in on line SMP supply with Power up to 500W. It is made of two devices. This switch modifies automatically the structure of the input diodes bridge in order to keep a same DC |
Original | ||||
| an390 | AN390 Application note How to use the AVS kit Introduction The AVS08, AVS10 and AVS12 are automatic mains voltage selectors to be used in online SMPS supplies with power up to 500 W. An AVS is made of two devices, a controller and an AC switch. The AC switch automatically modifies the structure of the input diode bridge in order to keep |
Original | ||||