ASEA OVER CURRENT RELAY Search Results
ASEA OVER CURRENT RELAY Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCK111G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 1.1 to 5.5 V, 3.0 A, Inrush current reducing / Reverse current blocking, WCSP6C | Datasheet | ||
| TCK301G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK304G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK305G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK321G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C | Datasheet |
Documents mentioning ASEA OVER CURRENT RELAY
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| rxih 2 | Info-N o. ASEA INFORMATION RK 413-300 E From /D ate Reg. Relay Division RFR, April 1970 Edition 1 5623 Page 1 Over-current relay type RXIH 2 Over-current relay RXIH 2 OUTSTANDING FEATURES • is built-up of static components • has out-put matched for a separate output relay |
OCR Scan | ||||
| rxide | Catalogue RK 47-10 E ASEA Edition 1 January 1972 File R, Part 1 Time-lag over-current relay îc ïô I m ïb TT type RXIDE 4 'iFjjjEjxP ® Registered trade mark Page Time-lag over-current relay type RXIDE 4 (81674) 2 2 co oo Relay p rotection incorporating tim e-lag over-current relay type RXIDE 4 mounted on a frame (81687 |
OCR Scan | ||||
| asea | Catalogue RK 42.-10E ASEA Edition 1 February 1972 File R, Part 1 Small over-current and over-voltage relays RXIC 1, RXID 1, RXEG 1, RXED 1 • Fixed or adjustable operating values D esign and mode o f operation V ersions M ounting M aintenance Technical data |
OCR Scan | ||||
| asea | In fo -N o . ASEA INFORMATION RK 40-311 E, Ed. From/Date Reg. RFR, October 1970 R e la y D ivision Page 5623 1 Over- and under-voltage relays type RREB OUTSTANDING FEATURES Measuring relay for d.c. or a.c. Over- or under-voltage relay High resetting ratio > 97% and < 103% |
OCR Scan | ||||
| asea | Info-No. ASEA INFORMATION Relay Division RFR Edition 1 RFR 1114 E From/Date Reg. Nov. 1970 Page 5620 1 Pci.890 400 Measuring relays for current and voltage This is a preliminary publication, based on information to be included in Pamphlet RK 4 0 -2 0 1 E. |
OCR Scan | ||||
| i ASEA Catalogue RK 93 E Edition 1 May 1966 File | i ASEA Catalogue RK 93 E Edition 1 May 1966 File R Part 2 Frames and connectors for relays Contents: Front terminals Extension bolts and terminal screws Flush mounting frames Blanking plates Adapting frames Relay testing block RTNP P -2 3 4 9 9 10 ASEA Front terminals |
OCR Scan | ||||
| Info-N o. ASEA INFORMATION RK 821-300 US, | Info-N o. ASEA INFORMATION RK 821-300 US, From/Date Reg. Page RFR, October 1972 5631 1 Ed. 2 Relay Division Type RXCN 4 Voltage regulating relay OUTSTANDING FEATURES A S tA , 8-721 S3 V ie te ria Sweden • Used for capacitor bank voltage control etc. • |
OCR Scan | ||||
| trc 4800 | A C ET A INFORMATION Into-No. RK 279-300 E Froinrt?sli Reg. E'FR, September 1977 Edition 2 Relay Division Page 5634 1 File RK 00-90 Section 2 Supervision relay' i-ype TRC 4800 Type TRC 4800 supervises continuously the trip circuits of a circuit breaker and will give alarm fori |
OCR Scan | ||||
| rxeg 21 | ASEA Catalogue RK 41 -15 E Edition 1 1980-07 File R, part 1 Over- and under voltage a.c. relay type RXEG 21 The RXEG 21 voltage relay can be set tc operate fo> either overvoitage or undervoltage The relay is suitable for use, amongst other things, in overvoltage protections. |
OCR Scan | ||||
| ASEA Catalogue RK 31-10 E Edition 2 November 1974 | ASEA Catalogue RK 31-10 E Edition 2 November 1974 Time-lag relay type RXKT 2 □ is available with tim e scales 0.2—2 s, 1—10 s, 6 -6 0 s and 0 .5 -5 min Is suitable fo r d.c. supply Requires no auxiliary voltage □ Is used in, for example, relay protections and automatic equipment for |
OCR Scan | ||||
| INFORMATION F rS n /D s ty m ‘"ftp 600-005 Reg. | INFORMATION F rS n /D s ty m ‘"ftp 600-005 Reg. RFA 1981-12-15 Edition 1 S id a 1 RELAY CIRCUITS IN HIGH VOLTAGE POWER PLANTS AND SUBSTATIONS 1 Introduction The relay equipment in power plants and substations is in fluenced by various environmental conditions. One of the most |
OCR Scan | ||||
| rrmv | ASEA Catalogue RK 12-1 E Edition 2 December 1965 File R, Part 2 Throw-over relays RRMVB 2 and RRMVB 4 • With 8 and 16 contacts respectively, arranged in two groups • 2 contacts are used to cut off the sup ply as soon as throw -over is complete • An RRMVB relay does not draw any |
OCR Scan | ||||
| Under-vdltage relay under-voltage protect1.0n | Under-vdltage relay under-voltage protect1.0n .Three-phase .Comprises .Used RROTC 2 silicon semiconducto with neutral for single-phase .Requires no auxiliary .Tripping carried out over .Two-seat plug-in unit value for three-phase j .Operates of 1 .I design |
Original | ||||
| <v i r™ * ■ j- Info-No. A S I ^ A INFORMATION | <v i r™ * ■ j- Info-No. A S I ^ A INFORMATION From/Date RFR, Feb. 1974 Edition 1 Relay Division RK 821-3C1 E Reg. Page 5651 1 File RK i>0-90 -E Section 8 Compensating; devices types RXTND 21 and RXTND 22 GENERAL Type RXTND 21 or RXTND 22 is used for compensation of |
OCR Scan | ||||
|
|
||||||
| rxko | A SEA Catalogue RK 31-13 E Drop-out-delayed time-lag relay type RXKO ■ Time-lag scales 0.4—2 s, 1.5—6 s and 4 -2 0 s ■ D.C. or a.c. supply, 15—60 Hz ■ Provided with a two-way contact ■ Short total resetting tim e ■ Designed for protective relay schemes |
OCR Scan | ||||
| b03-8210e | . Al li Hi 1% » ASEA BROWN BOVERI ABB Relays Type RAAD B03-8210E S m a ll Sstation t 3 t i ^ n aautomatic n t n m a t ir Small Januar$ 5,0chang e ncœ S * New restoration equipment Abstract • Easy to install and program • Provides fast restoration at substation outages |
OCR Scan | ||||
| Catalogue RK 65-17 E Edition 2 A p r ili 961 File | Catalogue RK 65-17 E Edition 2 A p r ili 961 File R, Part 1 ■ Time-overcurrent protective relays • Used as short-circuit and earth-fault re lays for cables, power lines, machines and transformers • independent or inverse time-iag characteristic • One, two and three phase protection with separale m eas |
OCR Scan | ||||
| A S E A Information Fram /tielS EER, O ct. 1975 E | A S E A Information Fram /tielS EER, O ct. 1975 E d it io n 1 Relay Division “ ■ 000-500 E' ie g , Fags 5633 1 D e sig n o f S t a t i c B e la y a , S ta b i ll iin g A u h IH w T im * u t t f f ia ^ tro tta ^ * l ü p p l ï - f S - - ç z £ - DC niter |
OCR Scan | ||||
| A S E A In fo r m a tio n From/Date Relay | A S E A In fo r m a tio n From/Date Relay Division R K 861- 3 0 0 E Reg. RFR Sept. 1973 Edition 2 5891 Page 1 SYNCHRO NIZER TYPE RASA • The permissible frequency difference for synchronizing pulse is settable between 0.2 and 0.4 Hz • The synchronizing pulse is given somewhat prior to exact inphase condition |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| rxotf | Three-phase over-voltage and under-voltage relay type RROTF 4 Corresponding relay of type COMBIFLEX® design has the type designation RXOTF 4 and is described in Information RK 434-300 E. • Operates for symmetrical and asymmetrical voltage changes and for open-circuit in three-phase networks |
Original | ||||
| brown boveri | A ll II « ■ k ■ MW mW ASEA BROWN BOVERI i— >i ABB Relays Type RADHO J y ■| ~ ■| ■ i-iDer optic pilot wire differential relay B03-7010E Page 1 January 1987 Data subject to change without notic 1 o n A bstract o A p plica tion |
OCR Scan | ||||
| Catalogue RK 9 2 -1 E T H E A S E A PLU G -IN | Catalogue RK 9 2 -1 E T H E A S E A PLU G -IN RELAY SYSTEM Relay sets based on tt» ASEA plug-ln system ill easily made up using relays and relay components six case sizes giving from 2 to 42 relay seata. Plug-In relays occupy 1, 2 or 4 relay seats a wide variety of components — auxiliary relays, signal relays and Indicating devices, |
OCR Scan | ||||
| II II MilIP II ASEA BROWN BOVERI ABB Relays | II II MilIP II ASEA BROWN BOVERI ABB Relays Abstract Application • Measures direct current, for instance at the voltage transformers’ neutral point connec tion to ground • Adjustable operate value 1 0 -1 5 mA • Adjustable operate time 0.3—3 s Page 1 |
OCR Scan | ||||
| ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part | ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part 1 ClOlMiBll iFlLlElXÍ Two or three-phase timeovercurrent protective relays Contarli* General Design Setting Diagrams Installation Ordering Reference publications Cl oj CJ For machines, transformers, cables and |
OCR Scan | ||||