AG1170 Search Results
AG1170 Datasheets (4)
Silver Telecom
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| AG1170 | Silver Telecom | +5V / +3.3V Low Power Ringing SLIC | Original | 361.45KB | 15 | ||
| AG1170-D3 | Silver Telecom | +5V / +3.3V Low Power Ringing SLIC | Original | 361.45KB | 15 | ||
| AG1170-D5 | Silver Telecom | +5V / +3.3V Low Power Ringing SLIC | Original | 361.44KB | 15 | ||
| AG1170-S5 | Silver Telecom | +5V / +3.3V Low Power Ringing SLIC | Original | 361.44KB | 15 |
AG1170 Price and Stock
Silver Telecom Ltd
Silver Telecom Ltd Ag1170-S5Interface Development Tools Subscriber Line Interface Circuit (SLIC), Long Loop, Fixed 600O Input & Network Balance Impedance, Internal Ringing, 5V Supply Voltage, Single-in-line (SIL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
Ag1170-S5 | 430 |
|
Buy Now | |||||||
Silver Telecom Ltd Ag1170-PS5Interface Development Tools Subscriber Line Interface Circuit (SLIC), Long Loop, Programmable Input & Network Balance Impedance, Internal Ringing, 5V Supply Voltage, Single-in-line (SIL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
Ag1170-PS5 | 25 |
|
Buy Now | |||||||
Silver Telecom Ltd Ag1170-S3Interface Development Tools Subscriber Line Interface Circuit (SLIC), Long Loop, Fixed 600O Input & Network Balance Impedance, Internal Ringing, 3.3V Supply Voltage, Single-in-line (SIL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
Ag1170-S3 |
|
Get Quote | ||||||||
Silver Telecom Ltd Ag1170-D5Interface Development Tools Subscriber Line Interface Circuit (SLIC), Long Loop, Fixed 600O Input & Network Balance Impedance, Internal Ringing, 5V Supply Voltage, Dual-in-line (DIL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
Ag1170-D5 |
|
Get Quote | ||||||||
Silver Telecom Ltd Ag1170-PS3Interface Development Tools Subscriber Line Interface Circuit (SLIC), Long Loop, Programmable Input & Network Balance Impedance, Internal Ringing, 3.3V Supply Voltage, Single-in-line (SIL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
Ag1170-PS3 |
|
Get Quote | ||||||||
Documents mentioning AG1170
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ag2120 | Silver Modem Interface using Ag2120 and Ag1170 +3.3V TELECOM 100pF 390K CMX850 Vcc DMa DMb LINERXF 100K Ag2120 100K 100nF LSC RS F/R LC RING VBIAS 0.33µF Vin Typical Protection: PTC: TR600-150 (Raychem) X1: TVB200SA (Raychem) ZB ZT2 GND ZT1 LINETXP 100nF |
Original | ||||
| ag1170 | Interfacing Ag1170 to Analog Devices AD73311 10R 100nF +3.3V 100uF 6.3V + Protection is for on-premise applications GNDA +VA 100R VINP VOUT D1 100nF D5 PGND DSP AD73311L Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 D2 47nF 10K TIP REFOUT RING D3 VIN D4 VOUTP 100nF |
Original | ||||
| ag1170 | Interfacing AG1170 to Atelic CODEC 10R 100nF +3.3V 100uF 6.3V + GNDA Protection is for on-premise applications 100pF +VA Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 AT8*45 100k VIN D1 100nF 100k PGND D5 D2 TIP RING D3 VOUT D4 100nF F/R PD RM SHK PGND +VPWR GNDPWR |
Original | ||||
| bzt03c82 | Interfacing Ag1170 to AK2304 10R 100nF +5.0V 100uF 6.3V + Protection is for on-premise applications GNDA +VA Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 AK2304 100nF CH1 VIN RA1 D1 RG1 + 4.7uF TD PCM BUS RD PGND D5 D2 56K TIP 100nF VOUT RING D3 SYNC PGND RSYNC TA1 |
Original | ||||
| ag1170 | Ag1170 DTMF Application using CMX605 VCC 10R 100nF 100nF 100uF 220uF 6.3V 10V + + Protection is for on-premise applications GNDA +VA Low ESR +VPWR Ag1170 D1 µC CODEC GNDPWR D1 = BZT03C82 D2 - D5 = 1N4004 VOUT 100nF 100nF PGND D5 VIN D2 TIP TIP PD 10K RING |
Original | ||||
| ag1170 | Silver TELECOM Ag1170 Ringing Performance The ringing capability of the Ag1170 is specified as 40Vrms into 3 REN on a 500 ohms line (3km). Ringer Equivalence Number (REN) is a measure of the impedance of a telephone ringer circuit and 1 REN is defined to be equivalent to a standard telephone, which, at |
Original | ||||
| ag1170 | Design Considerations during Power Up of Ag1170 During Power Up the RM pin must be held low. Failure to do so may result in damage to the integral DC/DC converter on the module. Figure 1 shows a typical configuration where the RM pin is driven from a controller. When the controller output is configured it must be programmed high to ensure that |
Original | ||||
| ag1170 | Interfacing Ag1170 to CMX865A and TWL3025/CAL2M000 VCC 10R 100nF 100nF 100uF 470uF 6.3V 16V + + Protection is for on-premise applications GNDA +VA TWL 3025 +VPWR CAL2M000 GNDPWR D1 = BZT03C82 D2 - D5 = 1N4004 Ag1170 D1 VOUT 100K AUXI 100nF PGND 100nF SDI SDO |
Original | ||||
| ag2120 | Modem Interface using Ag2120 and Ag1170 +3.3V 390K 100pF CMX868/869 DMa DMb Vcc 10uF RXAFB Ag2120 PTC RLY-1 RXAN Vout RXA TIP Central Office Line 100K 100K 100nF LSC RS F/R LC X1 RING 100nF VBIAS RLY-2 TXA IRQN REPLY DATA CSN SERIAL CLOCK COMMAND DATA Vin |
Original | ||||
| ag1170 | Power Down and Synchronisation of Ag1170 The internal oscillator will “free run” when the PD pin is left open-circuit. SYNCHRONISATION OR POWER DOWN POWER DOWN ONLY To PD pin & 0V to +3/+5V Square Wave H = SYNC L = PD To PD pin 10K BC846 or equivalent |
Original | ||||
| ag2120s | Dual Layout of Ag2120S & Ag1170S COIC connections and components are shown in brackets [ ] [ZT] [ZC] [ZB] Pin Outs 1170S SLIC 2120S COIC RING [RING] TIP [TIP] F/R [Cathode] RM [Anode] SHK [Gate] ZT1 [DMB] ZT2 [DMB] - - - - - - - - ZB [LC] VIN [VIN] VOUT [VOUT] |
Original | ||||
| ag1170 | Silver TELECOM Ag1170 Power Down Control The Ag1170 on-board DC/DC converter can be powered down to reduce the operating supply current when the system is in idle mode. This can be done with a transistor as shown in AN1170-12 or with a diode as shown in Figure 1. |
Original | ||||
| ag1170 | Interfacing Ag1170 to Conexant CX06833 Modem 10R 100nF +3.3V 100uF 6.3V CX06833 + GNDA Single Chip Modem +VA Ag1170 VIN D1 LINE_OUT_P 100nF PGND D5 D2 TIP POS Terminal D3 MIC_IN VOUT RING 100nF D4 F/R PGND HOST CONTROLLER RM Protection is for on-premise applications |
Original | ||||
| ag1170 | Silver Interfacing AG1170 to WAVECOM Q2403 TELECOM 100nF +5V 100uF 6.3V + Protection is for on-premise applications GNDA +VA Q2403 Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 10k VIN D1 SPK1P 100nF PGND D5 1nF 100nF D2 10k SPK1N TIP 62k RING D3 VOUT D4 100nF KEEP TRACK SHORT |
Original | ||||
|
|
||||||
| ag1170 | Interfacing Ag1170 to Analog Devices AD1885 10R 100uF 6.3V +3.3V + 100nF Protection is for on-premise applications GNDA +VA AD1885 AC’97 CODEC Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 VOUT D1 PHONE IN 100nF PGND D5 D2 TIP 5.6K RING D3 VIN D4 MONO OUT 100nF |
Original | ||||
| ag1170 | Silver TELECOM Ag1170 Simple Power Down Circuit The Ag1170 has a PD pin, which can be used to power down the module to reduce the operating supply current when the system is in idle (stand-by) mode. Normally this would be connected to a controller (via a transistor), but in cases where the controller is also shut down |
Original | ||||
| ag1170 | Impedance Programming the Ag1170P ZB VIN Z2 ZT1 Z3 ZT2 Z5 Z1 Z4 Network Balance Z6 Terminal Impedance NOTE: ZB, VIN, ZT1 and ZT2 are pin connections for the Ag1170P interface. See Ag1170 datasheet for more details. Line Impedance 600R 600R+2.16uF 370R+620R//310nF |
Original | ||||
| ag1170 | Silvertel Ag1170 DTMF Application using CMX865A VCC 10R 100nF 100nF 100uF 6.3V 220uF Protection is for on-premise applications GNDA +VA +VPWR 10V Low ESR CODEC GNDPWR D1 = BZT03C82 D2 - D5 = 1N4004 Ag1170 D1 VOUT PCM DATA µC RX 100nF PGND D5 VIN D2 TIP TIP |
Original | ||||
| ag1170 | Interfacing AG1170 to IDT821024 10R 100nF +5V 100uF 6.3V + Protection is for on-premise applications GNDA +VA IDT821024 Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 D1 VOUT IIN1 100nF PGND D5 Gain setting resistors IREF D2 Channel 1 of 4 channels PCM INTERFACE TIP |
Original | ||||
| mt91l62 | Interfacing Ag1170 to Zarlink MT91L62 10R 100nF +3.3V 100uF 6.3V + Protection is for on-premise applications GNDA +VA MT91L62 codec Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 VIN D1 AOUT100nF PGND D5 AOUT+ D2 TIP 10K RING D3 AIN+ VOUT 100nF D4 AIN- 10K SYNC F/R |
Original | ||||
| ag1170 | Interfacing AG1170 to TLV320AIC23B 10R 100nF +3.3V 100uF 6.3V + Protection is for on-premise applications GNDA +VA TLV320AIC23B Ag1170 D1 = BZT03C82 D2 - D5 = 1N4004 10k ROUT VIN D1 LOUT 100nF PGND D5 10k D2 TIP RING D3 RLINEIN VOUT D4 100nF LLINEIN F/R PD |
Original | ||||
| ag2120d | Dual Layout of Ag2120D & Ag1170D COIC connections are shown in brackets [ ] RB RC RD Pin Outs 1170D SLIC 2120D COIC TIP [TIP] RING [RING] IC (NC) [Cathode] PD [Anode] NC [Dma] NC [Dmb] RM [Gate] GNDA [GNDA] VA [Vcc] ZT2 [ZT2] ZT1 [ZT1] Zb [Zb] Vin [Vin] NC |
Original | ||||
| ag1170 | Modem Interface using Ag1170 and Ag2120 +3.3V 100pF 390K CMX850 Vcc DMa DMb LINERXF 100K Ag2120 LINERXN Vout PTC LSC RS F/R LC RING VBIAS 0.33µF Vin Typical Protection: PTC: TR600-150 (Raychem) X1: TVB200SA (Raychem) LINETXP 100nF ZB ZT2 GND ZT1 LINETXN 100K |
Original | ||||
| tp3070 | Interfacing Ag1170 to National TP3070 +5V 100nF 100nF -5V 10R 100nF 100uF 6.3V + Protection is for on-premise applications GNDA VCC +VA D1 SHK IL4 F/R IL0 IL1 RM PGND D5 IL3 TIP DCLK DIO VOUT D4 VIN PGND FS MCLK 10K RING D3 TP3070 PCLK PD D2 DXA DRA TSCA RST |
Original | ||||
| ag1170 | Ag1170 – Meter Pulse Interface Audio output From CODEC +5V 10nF 10k 1nF 2k Meter Pulse ON To Vin of Ag1170 1k 13k 1k 12kHz LM358 13k 3k3 LM358 3k3 100k 100nF 560pF 680pF Low Pass Filter AN1170-31v1-0 |
Original | ||||