Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    800A J TYPE FUSE Search Results

    800A J TYPE FUSE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-059FTYPEMM-025
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft PDF
    CO-059FTYPEMM-010
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft PDF
    CO-059FTYPEMM-050
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft PDF
    CO-059FTYPEMM-003
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft PDF
    CO-059FTYPEMM-006
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft PDF

    Documents mentioning 800A J TYPE FUSE

    Document Partial File Text Tags Type PDF
    I ON O OFF ABB PowerLine includes seven different
    I ON O OFF ABB PowerLine includes seven different amperage sizes from 30A to 800A. All PowerLine fusible switches are designed to meet customer requirements in terms of high interrupting capacity and long electrical life while occupying little more panel space than the appropriate fuses. The
    Original PDF
    Product Data CENTERLINE® Motor Control Centers
    Product Data CENTERLINE® Motor Control Centers Power Fuses Application The information in this publication applies to the selection of 3-phase motor power fuses when used in 460V and 575V applications, as well as to the selection of power fuses in branch circuit or non-motor applications.
    Original PDF
    High Speed Fuses Square Body French Style —
    High Speed Fuses Square Body French Style — 690V/700V (IEC/UL): 40-1500A 690V/700V (IEC/UL) 40-1500A Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms)
    Original PDF
    Disconnect Switches Section Contents Page 325
    Disconnect Switches Section Contents Page 325 Disconnect Switches Compact Circuit Protector (CCP) fused disconnect switches…326-329 Fused, dead front disconnect switches…329 Fusible Disconnect Switch Overview…330
    Original PDF
    Product Guide Product Guide Amp-Trap 2000® Fuses
    Product Guide Product Guide Amp-Trap 2000® Fuses AJT A2D & A6D A4BQ ATDR & ATQR Class J Time Delay 1 to 600A 600V AC, 200kA I.R. 300kA I.R. UL Witnessed 500V DC, 100kA I.R. Current Limiting UL Listed CSA Certified Smart Spot Indicator Motor, motor controller, control
    Original PDF
    Disconnects Section Contents Page RED indicates
    Disconnects Section Contents Page RED indicates NEW information 307 Disconnects Safety Module™ fused disconnect switch… 308-309 Coordination Module™ fused lighting and appliance panelboard… 310-311 Power Module™ — all-in-one
    Original PDF
    enclosed disconnect switch
    Enclosed Disconnect Switches Handles accept 3 padlocks to comply with OSHA lockout/tagout requirements Multiple knockouts available for flexibility in wiring Compact Fused switch completely isolates line and load side via double break contacts Utilizes popular
    Original PDF
    Isomax Molded case circuit breakers S3 – S8 15 Is
    Isomax Molded case circuit breakers S3 – S8 15 Is M oma CC x Bs S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = BA = BA3 = S_ = U_ = Auxiliary Switch Bell Alarm Bell Alarm (S6/S7 only) Shunt trip with voltage code Undervoltage release with voltage code
    Original PDF
    Fuse Switches ■ On load fuse switch to IEC 947-3
    Fuse Switches ■ On load fuse switch to IEC 947-3 ■ 3 and 4 pole versions ■ 20A to 630A ■ Door interlocked handles – defeatable ■ 3 padlock positions ■ DIN rail and chassis mount versions ■ Shaft length 100 - 500mm ■ Full range of accessories
    Original PDF
    Fuse Switches ■ On load fuse switch to IEC 947-3
    Fuse Switches ■ On load fuse switch to IEC 947-3 ■ 3 and 4 pole versions ■ 20A to 630A ■ Door interlocked handles – defeatable ■ 3 padlock positions ■ DIN rail and chassis mount versions ■ Shaft length 100 - 500mm ■ Full range of accessories
    Original PDF
    fuses
    Bussmann® Fuses in Hazardous Locations Class I Division 1 Fuses located in Class 1 Division 1 locations are required to be provided with enclosures that are identified as sa complete assembly for use in Class 1 locations [501.115(A)]. Class I Division 2 NEC Section 501.115(B)(3) addresses the use of current-limiting fuses in Class I Division 2
    Original PDF
    Product Catalog UL Fuses: Current Limiting
    Product Catalog UL Fuses: Current Limiting Circuit Protection Table of Contents General Catalog Contents Page UL Fuses: Current Limiting Class RK5 Class RK1 Class RK Class L Class J Class T Class G Class CC Dual-Element, Time-Delay - ECNR/ECSR…1
    Original PDF
    194R IEC Fused and Non-Fused Rotary Disconnect
    194R IEC Fused and Non-Fused Rotary Disconnect Switches 194R IEC Fused and Non-Fused Rotary Disconnect Switches Versatility The Bulletin 194R Disconnect switches offer unparalleled versatility. The switches offer a variety of fused and non-fused versions from 20A- up to 800A. All 194R’s possess the most-often
    Original PDF
    Next KLLU Class L Fuses 600 VAC ■ Time-Delay ■
    Next KLLU Class L Fuses 600 VAC ■ Time-Delay ■ 601 – 4000 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact factory Interrupting Ratings: 200,000 amperes rms symmetrical Ampere Range: 601 – 4000 amperes Approvals: Standard 248-10, Class L
    Original PDF
    fuses
    Product Catalog Special Purpose Fuses Circuit Protection Table of Contents General Catalog Contents Page Special Purpose Fuses Cable Limiters Capacitor Fuse, Non-Time-Delay Lift Truck Fuses Limiters High Speed Fuses, Trip Indicators Microswitch Adapter Type “D” Bottle Fuses
    Original PDF
    l15s
    Next Semiconductor Fuses 150/250/500/600/700 VAC ■ Very Fast-Acting ■ 1 – 1000 Amperes SPECIFICATIONS Voltage Ratings: L15S: 150 V AC/DC (1 – 60A) 150 VAC (70 – 1000A) 100 VDC (70 – 1000A) L25S: 250 V AC/DC (1 – 200A) 250 VAC (225 – 800A) 200 VDC (225 – 800A)
    Original PDF
    General Purpose Fuses IEC General Purpose Fuses
    General Purpose Fuses IEC General Purpose Fuses IEC BS88-2 Fuses gG/gM Sizes A,B,C • The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. • These fuses are designed for : - “General purpose use” protection (gG type) - motor protection (gM type)
    Original PDF
    High Speed Fuses Square Body Fuses General
    High Speed Fuses Square Body Fuses General Information Introduction Square Body Contents Page Application Information 115-116 Volts (IEC/UL) Size 000,00 690/700 1*, 1, 2, 3 1*, 2, 3 4 23, 24 00, 1, 2, 3 00 1000 1*, 1, 2, 3 4 24 1*, 1, 2, 3 1250/1300 1000-2000
    Original PDF
    dgt409bca
    DGT409BCA DGT409BCA Reverse Blocking Gate Turn-off Thyristor Replaces January 2000 version, DS4414-4.0 APPLICATIONS The DGT409 BCA is a symmetrical GTO designed for applications which specifically require a reverse blocking capability, such as current source inverters (CSI). Reverse
    Original PDF
    2100-ca001
    CENTERLINE® 2100 Motor Control Center Specification Checklist Refer to the CENTERLINE® 2100 Motor Control Centers catalog, publication 2100-CA001x-EN-P, for detailed information about the configuration and limitations of the sections, units and options being offered.
    Original PDF
    fusible
    Productivity Through Protection™ Disconnect Switches Table of Contents Disconnect Switches Compact, Heavy-Duty Enclosed Fusible Disconnect Switches…Page 71 Enclosed Non-Fusible Disconnect Switches…Page 75 Index by Part Number… Page 86
    Original PDF
    pd800a-series
    UUBDAA PD800A-SERIES DENSEI-LAMBDA AC-DC Front end power module ■ Features • Wide Range Input 88 - 265VAC High efficiency 90% (typ) Conducted EMC : EN55022-A Power Factor Correction : EN61000-3-2 Susceptibility : EN61000-4-2,-3,-4,-5,-6
    OCR Scan PDF