WN2 4HR Search Results
Documents mentioning WN2 4HR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ferrocode | Interlock Switches Non contact Switches Ferrocode Specifications (continued) Utilization Category (AC) 4A/250V AC/1000VA at COSϕ=1 Max Switched DC Current/Volt 2A/30V DC/60W Min Switched DC Current/Volt 10mA/10V Description Max Output Fuse 5A quick acting |
Original | ||||
| ENGLISH The CU2 provides a stopped motion | ENGLISH The CU2 provides a stopped motion detection system and is used together with CU2 sensors (supplied separately) to detect movement of a machine via the flywheel, gear or shaft etc. Upon energisation the unit powers up (Red LED). When the sensor detects that the |
Original | ||||
| ferrocode | The following example shows how to connect a Ferrocode Switch to a Sipha 2 Control Unit. The wire colour's although similar are connected differently between the Sipha and Ferrocode Products Ferrocode 24V DC N/C Circuit N/O Circuit Red & Blue Black & White |
Original | ||||
| ferrogard | FERROGARD MAGLOCK GS2, GS2H & GS2-1 GUARD SWITCHES Certification for GS2 & GS2-1. EExdIICT6 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000. Certification for GS2H. EExdIICT3 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000 |
Original | ||||
| minotaur | R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity: |
Original | ||||
| minotaur msr9t | MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633 |
Original | ||||
| INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / | INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / NOTICE D'INSTALLATION 4 1mm min 2.5mm max 2 x M4 2 6 2 x M4 5 1 3 2.5mm y Entr End mm & nt Fro in. 150 m B1 B2 0mm . 20 mm n i try m 150 t En min. Fron Entry End 2 x M4 2 ELF 1 Conduit M16 PG9 entry Part 33001 33002 |
Original | ||||
| minotaur msr8t | See enclosed Declaration of Conformity for details. Siehe Anlage: Konformiätserklärung. Voir la declaration de conformite ä-jointe pour details MINOTAUR MSR8T SINGLE CHANNEL INPUT MONITORING SAFETY RELAY & EXTENSION UNIT. RELAIS-SICHERHEITSBAUSTEIN FÜR SICHERHEITSSCHALTER UND NOT-AUS-BEFEHLSGERÄTE (1-KANALIGER EINGANG) UND ERWEITERUNGSEINHEIT. |
Original | ||||
| See enclosed Declaration of Conformity for | See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. SPECIALISTS IN MACHINERY SAFETY UL C UL R 940060 R Listed UNIVERSAL TONGUE OPERATED SAFETY INTERLOCK SWITCH. |
Original | ||||
| minotaur msr6r/t | See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte. |
Original | ||||
| ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security | ACCESSOIRES ZUBEHÖR (e) ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function |
Original | ||||
| msr15d | Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät |
Original | ||||
| minotaur | (a) Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite |
Original | ||||
| (a) CU3 Description The CU3 has been designed to | (a) CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor |
Original | ||||
|
|
||||||
| mt-gd2 | HEAVY DUTY, TONGUE OPERATED GUARD INTERLOCK SWITCH MT-GD2 (a) The MT-GD2 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. |
Original | ||||
| msr16 | (a) MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after |
Original | ||||
| minotaur | (a) MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously |
Original | ||||
| (a) CADET 3 Description The Cadet 3 is a positive | (a) CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions |
Original | ||||
| msr12t | MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE (b) Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only |
Original | ||||
| ferro | FERROGARD GD2 (b) Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch |
Original | ||||
| ferrogard | (a) Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details. |
Original | ||||
| solenoid lock | ATLAS 5-GD2 (a) HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the |
Original | ||||
| trojan 5 | TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 (a) Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. |
Original | ||||