Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WAVEGUIDE GASKETS Search Results

    WAVEGUIDE GASKETS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MRJ258A21BP
    Amphenol Communications Solutions MRJ Series, Panel Gasket PDF
    FLA2N01BP
    Amphenol Communications Solutions FLA Panel Gasket NEMA ANSI C136.41, EPDM Rubber, Black PDF
    FLA2N04BP
    Amphenol Communications Solutions FLA Panel Gasket NEMA ANSI C136.41, Silicone Rubber, Black PDF
    MUSB2B551041BP
    Amphenol Communications Solutions Rugged USB Mini B Accessory, Input Output Connector, Panel Gasket, Conductive Rubber PDF
    FLBP77012
    Amphenol Communications Solutions FLB Base NEMA ANSI C136.41, 76mm, 3 Power, 4 Signal, Vented, Silicone Gasket PDF

    WAVEGUIDE GASKETS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    M83528

    Abstract: WR340 flange dimensions OSD-6411A wr 2300 flange waveguide Waveguide Gaskets 20-03-3731-1212 CMR-137 WR137 gasket dimensions RG-106 wr 2300 waveguide flange
    Contextual Info: CONDUCTIVE ELASTOMERS Waveguide Gaskets Waveguide Gaskets CHO-SEAL CHO-SEAL 1212 1239 SPECIFICATIONS Type Ref: MIL-G-83528 Volume Resistivity (ohm-cm, max) as supplied (without pressure-sensitive adhesive) K G 0.005 0.007 Hardness (Shore A ±5) 80 80 Specific Gravity (±0.25)


    Original
    mil-g-83528m83528wr340 flange dimensionsosd-6411a+7wr 2300 flange waveguidewaveguide gaskets20-03-3731-1212cmr-137wr137 gasket dimensionsrg-106wr 2300 waveguide flange PDF

    177DZ

    Abstract: elliptical waveguide EWP63S EW37 waveguide elliptical EW77 EW64 waveguide ew64 143Z EWP43
    Contextual Info: Accessories A Splice. B Hoisting Grip used at 200 ft 60 m intervals to raise waveguide on tower. C Bending Tool Kit for elliptical waveguide installation. One each E- and H-plane form included. D Connector Reattachment Kit includes rubber gasket parts (except flange gaskets) which may need


    OCR Scan
    ewp34ewp37ewp43ewp52+14ewp63sewp64128az134dz137dz152dz177dzelliptical waveguideew37waveguide ellipticalew77ew64 waveguideew64143z PDF

    WS108

    Abstract: WC166 WC281 Waveguide Gaskets CPR159G CPR-137 circular waveguide
    Contextual Info: Circular-to-Rectangular Waveguide Transitions A Term ination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. F la n g e Type Lo ad Type No.


    OCR Scan
    cpr90gcpr112gcpr137gcpr159g+10cpr229gwr112wr137wc281wc166wc109ws108waveguide gasketscpr-137circular waveguide PDF

    waveguide transition

    Abstract: Wc waveguide ELBOW WR1500 wr -34 flange waveguide
    Contextual Info: GU IDELin e Circular Waveguide li rüculüiiiit Aiiteiuis. Systems GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than


    OCR Scan
    glw1350glw1500glw1700glw1750+4waveguide transitionwc waveguideelbow wr1500wr -34 flange waveguide PDF

    WC166

    Abstract: WC281 WC109 elliptical waveguide flexible waveguide 4 port combiner sliding
    Contextual Info: A Alignment Shorting Plate. A brass plate used during initial alignment. It is installed at the top of the run while the axial ratio compensator is adjusted. See table below. B Pulling Head. Attaches to top waveguide section flange. Waveguide sections can be assembled at


    OCR Scan
    wc281wc166wc109elliptical waveguide+3flexible waveguide4 port combinersliding PDF

    WC281

    Contextual Info: M ic ro w a v e T ra n s m is s io n Lin es Circular W aveguide Low est Attenuation Circular waveguide offers substantially lower attenuation than elliptical or rectangular waveguide. This can result in the use of smaller antennas, reducing tower loading and saving antenna cost.


    OCR Scan
    8600a-1-8600a-2-8613a-150-8613a-96-+28613a-wc281 PDF

    GLW1500

    Abstract: GLW-1350 waveguide transition ELBOW WR1500 GLW1750 GLW1700 wr -34 flange waveguide
    Contextual Info: GUIDELine Circular Waveguide GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than rectangular waveguides. The unique design offers superior polarization stability and eliminates the need for on-site


    Original
    glw1350glw1500glw1700glw1750+4glw-1350waveguide transitionelbow wr1500wr -34 flange waveguide PDF

    wr1500 55

    Abstract: GLW1500
    Contextual Info: B ro a d c a s t A n te n n a S y s te m s GUIDELine Circular Waveguide GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than


    OCR Scan
    glw1750glw1700glw1500glw1350+1wr1500 55 PDF

    andrew ew 90

    Abstract: EW17 33586 1127D EW 90 EWP63 EW20 P127A EWP34 EW77
    Contextual Info: Accessories A S p lic e . B H o is tin g G rip used at 200 ft 60 m intervals to raise waveguide on tower. C B e n ding Tool Kit for elliptical waveguide installation. One each E- and H-plane form included. D C on n e cto r R e a tta c h m e n t Kit includes rubber gasket


    OCR Scan
    1127dgb4-43gb4-52gb4-63+14gb4-64gb5-43gb5-52gb5-63gb5-64p127aandrew ew 90ew1733586ew 90ewp63ew20ewp34ew77 PDF

    WC281

    Contextual Info: Circular W aveguide Straight Sections Andrew circular waveguide is made of heavy-wail high conductivity copper tubing, specially coated to prevent corrosion and deterioration of attenuation characteristics. Stainless steel hardware and flange gaskets are included.


    OCR Scan
    wc281 PDF

    MIL-W-85

    Abstract: WR340 half height flange wr 2300 flange waveguide GSK90-1-S GASKET Waveguide Gaskets WR340 waveguide directional coupler wr 90 directional coupler wr 2300 waveguide RCC42 wr 90 x band flange waveguide
    Contextual Info: • RECTANGULAR WAVEGUIDE SECTION CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-101 DS-102 DS-103 DS-104 DS-105 DS-106 DS-107 DS-108 DS-109 DS-110 DS-111 Directional Couplers . .


    Original
    ds-101ds-102ds-103ds-104+16ds-105ds-106ds-107ds-108ds-109ds-110mil-w-85wr340 half height flangewr 2300 flange waveguidegsk90-1-s gasketwaveguide gasketswr340 waveguide directional couplerwr 90 directional couplerwr 2300 waveguidercc42wr 90 x band flange waveguide PDF

    wr75

    Abstract: pdr84 to pdr70 WR75 waveguide rectangular waveguide transition WC166 WR75 flange
    Contextual Info: Circular-to-Rectangular W aveguide Transitions These transitions convert from circular-to-rectangular waveguides at one or both ends of the vertical run. Transitions include swivel flanges to sim plify installation and polarization alignment. Both rectangular waveguide


    OCR Scan
    8016a-35321a-17459a-3wr75+5pdr84 to pdr70wr75 waveguiderectangular waveguide transitionwc166wr75 flange PDF

    WC281

    Abstract: WC166 WC109 WC269 WR75 waveguide WC212 3642 CPR159G rectangular waveguide transition CPR-159G
    Contextual Info: A Termination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. Flange Type Load Type No CPR90G CPR112G CPR137G CPR159G CPR229G WR75 Cover/Gasket


    OCR Scan
    cpr90gcpr112gcpr137gcpr159g+12cpr229gwr112wc281wc281ransitionswc166wc109wc269wr75 waveguidewc2123642rectangular waveguide transitioncpr-159g PDF

    WC281

    Abstract: CPR229G elliptical waveguide UG-595U WC166
    Contextual Info: M icrow ave Transm ission Lines Single Polarized Without Mode Filter Single Polarized With Mode Filter Circular-to-Rectangular Waveguide Transitions These transitions convert from circular to rectangular waveguides at one or both ends of the vertical run.


    OCR Scan
    pdr100pdr120ug-596a/uug-595u+7cbr220ubr220pbr220wc281cpr229gelliptical waveguidewc166 PDF

    WR137 gasket dimensions

    Abstract: PAR32 CBR84 gasket flanges UBR100 flange PBR120 UBR-120 CBR140 PBR-220
    Contextual Info: Choke, Cover and Cover/Gasket Flanges Choke, cover and cover/gasket flanges are square or round, depending on waveguide size. U. S. MIL and IEC versions are interchangeable. The flanges are pressurizable and require gaskets to ensure proper sealing. The flanges mate as explained below and as specified in the


    OCR Scan
    ug-595/uug-419/uub-39/uug-51/u+16ug-344/uug-149a/uug-53/uubr220ubr140ubr120wr137 gasket dimensionspar32cbr84gasketflangesubr100 flangepbr120ubr-120cbr140pbr-220 PDF

    UER70

    Abstract: UER84 WR137 flange dimensions UER100 flange dimensions CMR-187 rectangular waveguide CMR159 flanges CMR90
    Contextual Info: Rectangular Waveguide Flanges A majority of Andrew standard flanges utilized in North America are based on EIA Electronic Industry Association or U. S. Military (MIL) standards. IEC (International Electrotechnical Com m ission) standards are utilized throughout other parts of the world. EIA, MIL and IEC


    OCR Scan
    wr137uer100uer84uer70+10uer58uer48uer40wr137 flange dimensionsuer100 flange dimensionscmr-187rectangular waveguidecmr159flangescmr90 PDF

    Contextual Info: PBtttt G E C P L E S S E Y DS3541-1.1 F1052-57 HIGH POWER WAVEGUIDE DIFFERENTIAL PHASE SHIFT CIRCULATORS * FREQUENCY COVERAGE 2.7 to 37.0GHz * HIGH-POWER CAPABILITY This data sheet describes a range of 4-port differential phase shift circulators that may also be


    OCR Scan
    ds3541-1f1052-57f1052f1054+4f1056f1057f1053ubr84 PDF

    WC281

    Contextual Info: M ic ro w a v e T ra n s m is s io n L in es Accessories A Alignment Shorting Plate. A brass plate used during initial alignment. It is installed at the top of the run while the axial ratio compensator is adjusted. See table below. B Pulling Head. Attaches to top waveguide section


    OCR Scan
    wc2813555a PDF

    WR137 gasket dimensions

    Abstract: WR340 flange dimensions Waveguide Gaskets WR187 PDR120 CPR-340F UG-1352 pdr84 to pdr70 PDR48 Waveguide Gaskets Waveguide Gaskets wr90
    Contextual Info: Pressurizable Contact Flanges CPR and PDR series contact flanges are rectangular in shape and have clear holes secured with bolts and nuts. The flanges are pressurizable and require gaskets to ensure proper sealing. The flanges mate as explained below and as specified in the Mating Information table.


    OCR Scan
    cpr90fcpr112fcpr137fcpr159f+16cpr187fcpr229fcpr284fcpr340fcpr430fug-1736/uwr137 gasket dimensionswr340 flange dimensionswaveguide gaskets wr187pdr120cpr-340fug-1352pdr84 to pdr70pdr48waveguide gasketswaveguide gaskets wr90 PDF

    cmr137 flange

    Abstract: IEC154 WR51 CPR112G IEC154-2 WR90 waveguide transition CMR-187 pressure inlet andrew CPR229G CMR-137
    Contextual Info: M ic ro w a v e T ra n s m is s io n Lin es Common F lange A d a p ters Flange Type UG-51/U UG-52B/U UG Cover / Gasket CMR90 CMR112 CMR137 Transition to Type N Female Flange Adapters are available in many commonly used configurations, and when used with standard components,


    OCR Scan
    ug-51/uug-52b/ucmr90cmr112+14cmr137cmr159cmr187cmr229cpr112gcmr137 flangeiec154wr51iec154-2wr90 waveguide transitioncmr-187pressure inlet andrewcpr229gcmr-137 PDF

    TP116

    Abstract: WR975 waveguide AJ2194 circuit diagram of door interlock system magnetron 10 kw CPR975 BURLE-AJ2192 AJ2136V2 AJ2135 magnetron
    Contextual Info: Return To Product Page S94600E Magnetron Large Power Magnetron For Industrial Applications • • • • Ceramic-Metal Construction 50 kW CW at 915MHz All Magnetron Support Equipment Available Full Operating Guidance The BURLE S94600E is a fixed-tuned, magnetically


    Original
    s94600e915mhzaj2192tp116+9wr975 waveguideaj2194circuit diagram of door interlock systemmagnetron 10 kwcpr975burle-aj2192aj2136v2aj2135magnetron PDF

    TP116

    Abstract: AJ2194 AJ2135 WR975 waveguide AJ2136V2 AJ-2194 power supply magnetron power supply for magnetron BURLE-AJ2137V1 CPR975F
    Contextual Info: Return To Product Page 8684 Magnetron Large Power MagnetronFor Industrial Applications • • • • Ceramic-Metal Construction 30 kW CW at 915 MHz All Magnetron Support Equipment Available Full Operating Guidance The BURLE 8684 is a fixed-tuned, magnetically


    Original
    tp116aj2194aj2135wr975 waveguide+6aj2136v2aj-2194power supply magnetronpower supply for magnetronburle-aj2137v1cpr975f PDF

    stainless steel s130

    Abstract: st 212 coaxial cable RS625 circular waveguide
    Contextual Info: A lp habetical Ind ex Description Page Description Page Special A p p lica tio n . 717, 718 ValuLine . 127-149 ACE Bidirectional A m p lifie rs .678-681 W ireless T ele p h o n e .439


    OCR Scan
    wc281stainless steel s130st 212 coaxial cablers625+1circular waveguide PDF

    WR975 waveguide

    Abstract: power supply for magnetron magnetron 10 kw AJ2135 AJ2136V2 LS-5148 WR975 stub tuner waveguide AJ2192 LS51
    Contextual Info: RETURN TO MENU TP-116 Large Power Magnetrons Application Note Application Guide For BURLE Large Power Magnetrons BURLE magnetrons are built to generate tens increases, operating procedures and tube pro- of kilowatts of cw power at 915 MHz 896 MHz tection techniques become increasingly critical. Close attention to the installation, operation


    Original
    tp-116an-4985aj219292ls-5131+12cpr975f92ls-5130aj2194ls-5148wr975 waveguidepower supply for magnetronmagnetron 10 kwaj2135aj2136v2wr975stub tuner waveguidels51 PDF