WATER PUMP CONT Search Results
WATER PUMP CONT Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| HM2LS22A8JLF | Amphenol Communications Solutions | HM2LS22A8JLF-SHIELDING CONT TYPE, HM2 | |||
| HM2LS25A8JLF | Amphenol Communications Solutions | HM2LS25A8JLF-LOWER SHIELD CONT, HM2 | |||
| G861AD05212TEU | Amphenol Communications Solutions | Water 2.54mm Pitch Rightangle DIP, 1x5Pin, Matte Tin, NY66, Color-White, BAG | |||
| ICD26S13E4GX00LF | Amphenol Communications Solutions | D-Sub High Density Board Mount Connectors, Input Output Connectors, 26 way, Right Angle, Solder socket, >200 Mating Cycles, Harpoons + Insert UNC 4 - 40 + Elec cont | |||
| ICD44S13E6GL00LF | Amphenol Communications Solutions | D-Sub High Density Board Mount Connectors, Input Output Connectors, 44 way, Right Angle, Solder socket, >500 Mating Cycles, Harpoons + Insert M3 + Elec cont |
Documents mentioning WATER PUMP CONT
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| lf10-w | www.lefoo.com LF10-W Water Pressure Switch The LF10 water pressure switch is designed for reliable control of automatic pump systems. It can prevent a pump from starting if water pressure falls below cut-in pressure. It is available with a reset button to restore automatic operation when system |
Original | ||||
| CONTROLS CONTROLS NRU SERIES LIQUID LEVEL CONTROL | CONTROLS CONTROLS NRU SERIES LIQUID LEVEL CONTROL PUMP UP UL listed • CSA recognized LED Relay Indicator Three Styles Pump Up Control 4.7 kΩ to 100 kΩ Sensitivity 10 Amp SPDT Relay Control of conductive liquids (tap water, sea water, sewage, |
Original | ||||
| mc33937 | Analog, Mixed Signal and Power Management MC33937 Three-phase field effect transistor pre-driver Applications Simplified Application Drawing • Automotive systems VBAT • Cooling fan 33937 • Water pump VPUMP • Actuator controls • Fuel pump VSUP PUMP |
Original | ||||
| igniti | INTELLIGENT BUILDING SYSTEM STMicroelectronics SOLUTIONS CENTRAL HEATING SYSTEM FUEL POWERED FUEL IGNITION FUEL HEATER CENTRAL HEATING UNIT WATER TEMPERATURE CONTROL AND REGULATION WATER PUMP DRIVING FAN SPEED CONTROL COMMUNICATION INTERFACE GAS POWERED TEMPERATURE |
Original | ||||
| capacitive | Level Sensors Capacitive Level Detector Type CD50 DC • Basic capacitive water level sensor For water storage tanks in mini-pools and whirlpools Detection of excess water in the whirlpool tub Safety device to control the operation of the pump. |
Original | ||||
| water level | Sensor Interface Sump Pump Controller Author: Brian Iehl Hoffman Estates, IL Email:brian@dls.net PROBLEM Most older sump pumps have a single level float control to regulate when the pump is turned on and off. When the water level rises to the float control, the pump turns |
Original | ||||
| water pressure switch | www.lefoo.com LF16 Water Pressure Switch The LF16 water pressure switch provides reliable control for automatic pump systems. It is available in a normally closed switch configuration. 99 114 Specification Model Connection Factory Min On Max Off Differential |
Original | ||||
| throttle control | EPCOS Components for Powertrain Applications Water pump ● Large size ● Throttle control valve Transmission control unit (ambient, engine, oil, fuel tank, exhaust gases) ● Temperature measurement ● Starter generator Fuel pump, |
Original | ||||
| mc33927 | Analog and Mixed-Signal Fact Sheet MC33927 Three-phase field effect transistor pre-driver Applications • Automotive systems • Cooling fan Simplified Application Drawing VBAT • Water pump VBAT VPUMP • Actuator controls 33927 • Fuel pump • Electro-hydraulic and electric |
Original | ||||
Automate the Home Automatic Pump Controller Author: T.K. Mani Keraia, India email: epsilon@giasmd01.vsnl.net.in INTRODUCTION: It is very common in houses in high terrain or high rise buildings, that the public water supply does not have enough pressure to get the water into the overhead |
Original | |||||
| slvsc08 | DRV3210-Q1 www.ti.com SLVSC08 – MAY 2013 Three-Phase Brushless Motor Driver FEATURES DESCRIPTION • The DRV3210-Q1 device is a field-effect transistor (FET) pre-driver designed for three-phase motor control for applications such as an oil pump or a water pump. The device has three high-side pre-FET |
Original | ||||
| DRV3203-Q1 www.ti.com SLVSC09 – MAY 2013 | DRV3203-Q1 www.ti.com SLVSC09 – MAY 2013 Three-Phase Brushless Motor Driver FEATURES DESCRIPTION • The DRV3203-Q1 device is a field-effect transistor (FET) pre-driver designed for three-phase motor control for applications such as an oil pump or a water pump. The device has three high-side pre-FET |
Original | ||||
| submersible pump | Electronic Components APPLICATION NOTE www.ittcannon.com Connectors for Submersible Pumps April 2007 The Challenge To design a connector able to withstand with the tough requirements of a submersible pump for grey water. The connectors are used both on the supply cable of the pump and the float level |
Original | ||||
| drv3204-q1 | DRV3204-Q1 www.ti.com SLVSBT3 – MARCH 2013 Three-Phase Brushless Motor Driver FEATURES DESCRIPTION • The DRV3204-Q1 device is a field-effect transistor (FET) pre-driver designed for three-phase motor control for applications such as an oil pump or a water pump. The device has three high-side pre-FET |
Original | ||||
|
|
||||||
| sensorless bldc motor | Bus ICs Sensorless BLDC motor drivers for… BLDC electrical water pump BLDC Motor Control ICs Melexis Application Specific Standard Products benefits over generic discrete solutions Pressure Sensors Melexis developed its integrated BLDC controller solutions |
Original | ||||
| Bilge Pump Smart Sensor REED RELAYS REED SENSORS | Bilge Pump Smart Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction Design engineers today look for procuring a complete solution. If they can’t find this, they look for its component parts. This application refers to the development of a bilge pump on a boat, which senses accumulating water in |
Original | ||||
| hcs08 | 8-bit Modular Student Learning Kit Featuring the HCS08 “QG” family Excellent beginner’s architecture to teach and learn Simple device, small instruction set and removable DIP Common Course Applications • Sensor monitor and control Water level/pump actuator |
Original | ||||
| General Purpose Relay G7L • Ideally suited for | General Purpose Relay G7L • Ideally suited for high-inrush fluid pump controls: pool/spa, water processing, emergency, chemical industry, etc. • High-capacity, high-withstand voltage relay with no contact chattering for momentary voltage drops up to 50% of rated |
Original | ||||
| General Purpose Relay G7L • Ideally suited for | General Purpose Relay G7L • Ideally suited for high-inrush fluid pump controls: pool/spa, water processing, emergency, chemical industry, etc. • High-capacity, high-withstand voltage relay with no contact chattering for momentary voltage drops up to 50% of rated |
Original | ||||