Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WATER LEVEL INDI Search Results

    WATER LEVEL INDI Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TC7MP3125FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Bidirectional, 2-Bit x 2 Dual Supply Bus Transceiver, TSSOP16B, -40 to 85 degC Datasheet
    74LV4T126FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    74LV4T125FK
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC Datasheet
    7UL1T04NX
    Toshiba Electronic Devices & Storage Corporation One-Gate Logic(L-MOS), Inverter with Level Shifting, XSON6, -40 to 125 degC Datasheet
    74LV4T126FT
    Toshiba Electronic Devices & Storage Corporation Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, TSSOP14, -40 to 125 degC, AEC-Q100 Datasheet

    Documents mentioning WATER LEVEL INDI

    Document Partial File Text Tags Type PDF
    d9063
    D9063 Issued July 1988 Liquid level controllers The range of liquid level controllers available from RS, is designed primarily for use with water and water based liquids. The resistivity of water varies in accordance with the following table: Liquid resistivity table
    Original PDF
    Issued July 1998 232-3024 Data Pack D Liquid
    Issued July 1998 232-3024 Data Pack D Liquid level controllers Data Sheet The range of liquid level controllers available from RS, is designed primarily for use with water and water based liquids. The resistivity of water varies in accordance with the following table:
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 3, 11/2004 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection.
    Original PDF
    pressure sensor
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS • Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    PS-A (ADPW) Pressure sensor Built-in amplifier
    PS-A (ADPW) Pressure sensor Built-in amplifier and compensating circuit New PS-A PRESSURE SENSOR Direct water pressure detection type FEATURES TYPICAL APPLICATIONS 1. Not only air, now water pressure can be detected directly. • Water heaters (water level detection)
    Original PDF
    water level
    Application Usage > E-Field Imaging Device demonstration > Key pad detection > Water level detection Application Features Description E-Field demonstrator presents contactless sensing of human touch and water level based on Freescale’s Electric Field Imaging Device
    Original PDF
    an1950
    Freescale Semiconductor Application Note AN1950 Rev 4, 11/2006 Water Level Monitoring by: Michelle Clifford, Applications Engineer Sensor Products, Tempe, AZ INTRODUCTION Many washing machines currently in production use a mechanical sensor for water level detection. Mechanical
    Original PDF
    ez-10
    SERIES Water Detection sensor LA-T EZ-10 TH Water Detection Wire Flaw Detection Hot Melt Glue Detection PARTICULAR USE SENSORS EZ-10 Detects Water…reliably! FD-F4Ⅺ/F9Ⅺ FD-F8Y Liquid Level Sensing EX-F1 Marked Conforming to EMC Directive Strong Penetration Power
    Original PDF
    ez-10
    SERIES Water Detection sensor LA-T EZ-10 TH Water Detection Wire Flaw Detection Hot Melt Glue Detection PARTICULAR USE SENSORS EZ-10 Detects Water…reliably! FD-F4Ⅺ/F9Ⅺ FD-F8Y Liquid Level Sensing EX-F1 Marked Conforming to EMC Directive Strong Penetration Power
    Original PDF
    Floatless Level Switch (Ultra High-sensitivity
    Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL CSM_61F-UHS_-HSL_DS_E_2_3 Ideal for Detecting Ice, Pure Water, or Humidity • Applicable for detecting ice, pure water steam, humidity, or other substances that conduct electricity poorly.
    Original PDF
    Floatless Level Switch (Ultra High-sensitivity
    Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL CSM_61F-UHS_-HSL_DS_E_2_2 Ideal for Detecting Ice, Pure Water, or Humidity • Applicable for detecting ice, pure water steam, humidity, or other substances that conduct electricity poorly.
    Original PDF
    CONTROLS CONTROLS NRU SERIES LIQUID LEVEL CONTROL
    CONTROLS CONTROLS NRU SERIES LIQUID LEVEL CONTROL PUMP UP UL listed • CSA recognized LED Relay Indicator Three Styles Pump Up Control 4.7 kΩ to 100 kΩ Sensitivity 10 Amp SPDT Relay Control of conductive liquids (tap water, sea water, sewage,
    Original PDF
    ls03
    LS03 Series MEDER electronic Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Following materials are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF
    Floatless Level Controller (Ultra
    Floatless Level Controller (Ultra High-sensitivity Type) 61F-UHS/-HSL Ideal for Detecting Ice, Pure Water, or Humidity • Applicable for detecting ice, pure water steam, humidity, or other substances that conduct electricity poorly. • Two types of model available: Ultra high-sensitivity and variable
    Original PDF
    ls02
    Meder Electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    MEDER electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    ls03
    Meder Electronic LS03 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted horizontally for best results. Two versions are available: APPLICATIONS PP (Polypropylene) for water applications and dilute acids
    Original PDF
    conductive level controller
    omRon Conductive Level Controller 61F-GP-N2 Automatic Water Supply and Drainage Control ■ Ideal for level control of any conductive liquid. ■ Compact plug-in controller for single- or two-point control of conductive liquid level. ■ 24/110/120/220/230/240 VAC operation possible.
    OCR Scan PDF
    ls02
    MEDER electronic LS02 Series Level Sensors with Magnetic Floats DESCRIPTION Standard liquid level sensor. The sensor has to be mounted vertically for best results. APPLICATIONS Two versions are available: PP (Polypropylene) for water applications and dilute acids
    Original PDF